{"id":5201,"date":"2026-09-18T09:20:00","date_gmt":"2026-09-18T01:20:00","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5201"},"modified":"2026-11-16T15:26:27","modified_gmt":"2026-11-16T07:26:27","slug":"magnetic-separator-working-distance","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/de\/magnetic-separator-working-distance\/","title":{"rendered":"Einfluss der Sch\u00fctth\u00f6he auf die Magnetabscheidung mit \u00dcberbandmagneten"},"content":{"rendered":"\n<style>\n.cl-burden { --cl-primary:#0b2d52; --cl-heading:#061e38; --cl-text:#192b3d; --cl-soft:#edf4fa; --cl-line:#d3e1ec; color:var(--cl-text); font:inherit; font-size:17px; line-height:1.75; }\n.cl-burden *, .cl-burden *::before, .cl-burden *::after { box-sizing:border-box; }\n.cl-burden h2, .cl-burden h3 { color:var(--cl-heading); line-height:1.3; text-wrap:pretty; }\n.cl-burden h2 { font-size:30px; margin:0 0 14px; scroll-margin-top:6rem; }\n.cl-burden h3 { font-size:24px; margin:26px 0 8px; }\n.cl-burden p { margin:0 0 13px; overflow-wrap:anywhere; }\n.cl-burden ul, .cl-burden ol { margin:0 0 14px; padding-inline-start:1.5em; }\n.cl-burden li + li { margin-top:5px; }\n.cl-burden a { color:var(--cl-primary); text-decoration:underline; text-underline-offset:.14em; }\n.cl-burden :focus-visible { outline:2px solid var(--cl-primary); outline-offset:3px; }\n.cl-burden section, .cl-burden .cl-intro, .cl-burden .cl-nav, .cl-burden .cl-cta { display:block; margin:0 0 24px; padding:22px; border:1px solid var(--cl-line); border-radius:16px; background:#fff; }\n.cl-burden section { border-top:4px solid var(--cl-primary); box-shadow:0 2px 10px rgba(6,30,56,.05); }\n.cl-burden .cl-intro, .cl-burden .cl-nav, .cl-burden .cl-cta, .cl-burden [data-article-section=\"faq\"] { background:var(--cl-soft); }\n.cl-burden section > :last-child, .cl-burden .cl-intro > :last-child, .cl-burden .cl-nav > :last-child, .cl-burden .cl-cta > :last-child { margin-bottom:0; }\n.cl-burden .article-media { display:block; clear:both; margin:14px 0 18px; }\n.cl-burden .article-media img { display:block; height:auto; max-width:100%; margin-inline:auto; }\n.cl-burden .cl-table { display:block; overflow-x:auto; margin:12px 0 16px; }\n.cl-burden table { margin:0; width:100%; border-collapse:collapse; text-align:left; line-height:1.5; }\n.cl-burden th, .cl-burden td { padding:10px 12px; border:1px solid var(--cl-line); vertical-align:top; }\n.cl-burden thead th { background:var(--cl-primary); color:#fff; }\n.cl-burden tbody th { background:var(--cl-soft); }\n.cl-burden .cl-cta a { display:inline-block; border-radius:8px; padding:9px 15px; color:#fff; background:var(--cl-primary); }\n.cl-burden details + details { border-top:1px solid var(--cl-line); }\n.cl-burden details { padding:10px 0; }\n.cl-burden summary { cursor:pointer; font-weight:700; color:var(--cl-heading); }\n.cl-burden details p { margin:8px 0 0; }\n@media (max-width:767px) {\n  .cl-burden { font-size:16px; }\n  .cl-burden h2 { font-size:24px; }\n  .cl-burden h3 { font-size:20px; }\n  .cl-burden section, .cl-burden .cl-intro, .cl-burden .cl-nav, .cl-burden .cl-cta { margin-bottom:18px; padding:18px; border-radius:12px; }\n  .cl-burden section { border-top-width:3px; }\n}\n<\/style>\n<article class=\"cl-burden\" lang=\"en-US\">\n<div class=\"cl-intro\">\n<p><strong>A deeper conveyor load makes it harder for an overband magnet to lift buried iron out of the material stream. If the magnet must also be raised to clear that load, iron near the belt moves farther from the magnet face.<\/strong> Size the separator for the deepest load you expect it to handle at the proposed location, the belt speed at that load, and the steel pieces you need to remove. Then confirm that the pieces reach the reject bin during a loaded test.<\/p>\n<p>This guide covers suspended magnets used to remove tramp iron from bulk conveyors. It starts with the measurements you can take on an existing line and ends with the data to compare quotes and accept a machine.<\/p>\n<\/div>\n<nav class=\"cl-nav\" data-article-section=\"navigation\" aria-label=\"On this page\"><p><strong>On this page<\/strong><\/p><ol><li><a href=\"#depth\">How Does Burden Depth Affect Overband Magnetic Separation?<\/a><\/li><li><a href=\"#measure\">How Do You Measure Burden Depth and Magnet Clearance?<\/a><\/li><li><a href=\"#estimate\">How Can You Estimate Burden Depth From Throughput?<\/a><\/li><li><a href=\"#height\">How Low Can You Mount an Overband Magnet?<\/a><\/li><li><a href=\"#layout\">Should the Magnet Go Over the Belt or at the Head Pulley?<\/a><\/li><li><a href=\"#selection\">When Should You Choose a Permanent or Electromagnetic Separator?<\/a><\/li><li><a href=\"#feed\">How Can You Reduce Burden Depth Without Losing Throughput?<\/a><\/li><li><a href=\"#evidence\">What Evidence Shows a Magnet Can Reach Buried Iron?<\/a><\/li><li><a href=\"#troubleshoot\">Why Does an Installed Overband Magnet Miss Iron?<\/a><\/li><li><a href=\"#rfq\">What Should You Put in an RFQ and Acceptance Test?<\/a><\/li><li><a href=\"#faq\">Frequently Asked Questions<\/a><\/li><\/ol><\/nav>\n<section><h2 id=\"depth\">How Does Burden Depth Affect Overband Magnetic Separation?<\/h2>\n<p><strong>Burden depth affects how much material a steel piece must move through before the magnet can lift it free.<\/strong> Burden is the material riding on the belt. Depth is the height of that material above the belt at a specified point. A bolt near the top can lift clear quickly. A bolt at the bottom of the same load has more material above it and is farther from the magnet than the top bolt.<\/p>\n<h3>Why buried steel is harder to lift<\/h3>\n<p>A suspended magnet has to move the steel far enough, fast enough, for it to leave the product stream. A buried bolt may have to push aside stone or break free of sticky feed. At higher belt speed it also has less time in a given part of the field. Eriez\u2019s suspended magnet brochure lists burden depth, belt speed, and the size and shape of the iron among the factors that affect collection. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/SB-305-Eriez-Suspended-Magnet.pdf#page=5\" rel=\"nofollow noopener\" target=\"_blank\">Eriez SB-305, positioning and collection factors<\/a>.<\/p>\n<h3>What changes when the frame stays fixed?<\/h3>\n<p>If the magnet and belt stay in the same positions, a deeper pile leaves less room beneath the magnet and puts more material over a bolt at the belt bottom. The face-to-bolt distance stays the same. Raise the magnet to clear taller feed, and that same bolt starts farther from the magnet as well. This is why two lines with the same suspension height can have different pickup results, and why the same line can start missing bolts during feed surges.<\/p>\n<\/section>\n\n<section><h2 id=\"measure\">How Do You Measure Burden Depth and Magnet Clearance?<\/h2>\n<p><strong>Take a loaded belt profile at the proposed magnet station and label each measurement with its start and end points.<\/strong> For a troughed belt, record depth at the center and where the load runs on each side. Also note where the highest point is during a feed surge. A single centerline figure can miss an off-center ridge beneath the separator frame.<\/p>\n<h3>Measure the load across the belt<\/h3>\n<p>Record normal depth and the deepest recurring load you expect the magnet to handle. Note the largest protruding lumps separately, along with how often they occur. Use an approved fixed sensor, a calibrated view from a protected location, or an isolated survey under site procedures. Record feed rate and belt speed with each profile. A measurement taken during a quiet shift can understate the clearance needed on a busy one.<\/p>\n<h3>Put both clearance dimensions on the drawing<\/h3>\n<ul>\n<li><strong>Burden depth<\/strong> runs from the carrying belt to the top of the material at the same lateral position.<\/li>\n<li><strong>Suspension height<\/strong> runs from the magnet datum the supplier specifies to its stated belt datum. Mark both surfaces on the drawing.<\/li>\n<li><strong>Running clearance<\/strong> is the space between the upper envelope of the moving load and the lowest nearby part of the installed unit, including the cleaning belt or flights where they govern.<\/li>\n<li><strong>Magnet-to-target distance<\/strong> runs from the stated magnet face to the target location, such as a bolt beside the belt surface at the bottom of the load.<\/li>\n<\/ul>\n<p>Use plan and cross-section views to show the trough, belt edges, skirting, magnet and reject path. The Dings form asks separately for maximum burden depth, requested suspension height, and trough geometry. The Eriez installation manual illustrates how to dimension suspension height and check the conveyor edges on its own equipment. <a href=\"https:\/\/dingsmagnets.com\/wp-content\/uploads\/2025\/01\/Overhead-Magnet-Selection-Guide-and-General-OH-RFQ-1_25.pdf#page=1\" rel=\"nofollow noopener\" target=\"_blank\">Dings overhead magnet RFQ, page 1<\/a>. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez SM-323, suspension-height drawings<\/a>.<\/p>\n<\/section>\n\n<section><h2 id=\"estimate\">How Can You Estimate Burden Depth From Throughput?<\/h2>\n<p><strong>Divide volumetric flow by belt speed to estimate the loaded cross-sectional area. Divide that area by loaded width to get an average equivalent depth.<\/strong> This estimate helps size up a change in feed rate before a site survey. Maximum depth on a troughed or unevenly loaded belt still comes from its profile.<\/p>\n<h3>Estimate the loaded cross-section<\/h3>\n<p>If flow <em>Q<\/em> is in metric tonnes per hour, loose bulk density <em>\u03c1<\/em> in tonnes per cubic meter, and belt speed <em>v<\/em> in meters per second, then <strong>area <em>A<\/em> = <em>Q<\/em> \u00f7 (3,600 \u00d7 <em>\u03c1<\/em> \u00d7 <em>v<\/em>)<\/strong>, in square meters. Divide <em>A<\/em> by the actual loaded width in meters to get equivalent mean depth in meters. Use the bulk density of the conveyed material, including the voids between pieces. For U.S. units, use a consistent set such as cubic feet per minute for volume flow and feet per minute for belt speed. The result is square feet before dividing by loaded width.<\/p>\n<h3>Check the estimate against a peak profile<\/h3>\n<p>Suppose an aggregate conveyor carries 360 metric t\/h at 1.6 t\/m\u00b3 and 1.25 m\/s across a 0.8 m loaded width. The cross-sectional area is 0.050 m\u00b2 and the equivalent mean depth is 62.5 mm. At 480 metric t\/h with the other inputs unchanged, those figures rise to about 0.0667 m\u00b2 and 83.3 mm. If a profile taken during a surge reaches 145 mm at the magnet station, use that actual profile for the clearance check. The 83.3 mm mean represents the same area spread evenly across the width.<\/p>\n<p>Check that your throughput and speed describe the same interval. A weigh feeder\u2019s hourly average can smooth out a short slug that still has to pass beneath the magnet. Recycling Today gives an industry example of a burden estimate that uses a factor for conveyor geometry. <a href=\"https:\/\/www.recyclingtoday.com\/article\/magnetic-separation-basics\/\" rel=\"nofollow noopener\" target=\"_blank\">Recycling Today, Calculating Burden Depth<\/a>.<\/p>\n<\/section>\n\n<section><h2 id=\"height\">How Low Can You Mount an Overband Magnet?<\/h2>\n<p><strong>Use the lowest supplier-approved position that clears the full moving load and allows the separator to carry captured metal away.<\/strong> Check the clearance at the tightest point across the belt and along the magnet. A low point near a sidewall, a hanging flight or a long piece already caught by the magnet can control the installation.<\/p>\n<h3>Compare a fixed and raised installation<\/h3>\n<p>In this example, dimensions are vertical at one crossbelt station. The magnet face starts 400 mm above the local carrying surface. The controlling part of the cleaning assembly sits 35 mm below that face. The target is modeled at belt level. The readings below illustrate the geometry. The supplier and site team set the required running clearance for the actual unit.<\/p>\n<div class=\"cl-table\" role=\"region\" aria-label=\"Example clearance and target distance\" tabindex=\"0\">\n<table><thead><tr><th scope=\"col\">Load condition<\/th><th scope=\"col\">Face to belt<\/th><th scope=\"col\">Bed depth<\/th><th scope=\"col\">Clearance to assembly<\/th><th scope=\"col\">Face to belt-level target<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Normal load<\/th><td>400 mm<\/td><td>180 mm<\/td><td>185 mm<\/td><td>400 mm<\/td><\/tr>\n<tr><th scope=\"row\">Deeper load, same magnet position<\/th><td>400 mm<\/td><td>280 mm<\/td><td>85 mm<\/td><td>400 mm<\/td><\/tr>\n<tr><th scope=\"row\">Deeper load, magnet raised 50 mm<\/th><td>450 mm<\/td><td>280 mm<\/td><td>135 mm<\/td><td>450 mm<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<p>Raising the unit restores 50 mm of clearance and adds 50 mm to the bottom pickup distance. Test that new position if you need the added space. On a transfer with an angled magnet or a falling material stream, use the actual drawing and trajectory through the field. The vertical subtraction in this example applies at the stated cross-section.<\/p>\n<h3>Check the lower operating envelope<\/h3>\n<p>Ask which component defines the lowest point in operation and how the supplier accounts for belt sag, the cleaning belt profile and the size of the captured steel. Allow room for fines buildup and feed variation where they affect clearance. Verify the reject chute and collection bin can take the largest target. Eriez SM-328 addresses plowing and cleaning belt clearance for its hazardous-location series. Apply your own model\u2019s instructions and approved drawings. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-328-Eriez-Suspend-Electromagnet-Hazardous-IOM.pdf#page=7\" rel=\"nofollow noopener\" target=\"_blank\">Eriez SM-328, Suspension Height and Burden Depth<\/a>.<\/p>\n<\/section>\n\n<section><h2 id=\"layout\">Should the Magnet Go Over the Belt or at the Head Pulley?<\/h2>\n<p><strong>Start with the head-pulley discharge on a new conveyor if the material opens up there and the reject chute fits. A crossbelt position over the loaded belt can be a practical retrofit when the transfer is crowded or side discharge is easier.<\/strong> At the retrofit position, verify pickup of the hardest buried pieces through the full burden.<\/p>\n<h3>Check a crossbelt retrofit<\/h3>\n<figure class=\"article-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-crossbelt-magnetic-separator-installation-20260907-075204-1-1.webp\" alt=\"Check a crossbelt retrofit\" width=\"1000\" height=\"750\" loading=\"lazy\" decoding=\"async\"><\/figure>\n<p>The magnet spans the conveyor. On a self-cleaning unit, its cleaning belt typically carries captured iron to the side. Check the loaded width, the space available at both edges, and where the iron will fall. If the conveyor consistently loads to one side, include that side in the test. A favorable centerline pickup says little about coverage under an off-center ridge.<\/p>\n<h3>Check a head-pulley installation<\/h3>\n<p>Compare an inline magnet over the discharge trajectory and a crossbelt magnet mounted at the head. The Dings guide shows both arrangements and the crossbelt position over the loaded conveyor. At the head, the load may open up as it leaves the belt, helping release buried iron. Plot where the material goes at both the low and high operating speeds. Check the splitter, reject chute and nearby steel, including the head pulley, against the manufacturer\u2019s drawing. Product and iron need separate paths from pickup to discharge. <a href=\"https:\/\/dingsmagnets.com\/wp-content\/uploads\/2025\/01\/Overhead-Magnet-Selection-Guide-and-General-OH-RFQ-1_25.pdf#page=3\" rel=\"nofollow noopener\" target=\"_blank\">Dings overhead magnet selection guide, mounting layouts<\/a>.<\/p>\n<\/section>\n\n<section><h2 id=\"selection\">When Should You Choose a Permanent or Electromagnetic Separator?<\/h2>\n<p><strong>Compare both options at the installed height, peak burden and smallest critical target. Select the cleaning method separately based on how often iron arrives and how the line can handle it.<\/strong> A deep burden can justify evaluating an electromagnet, especially when the mounting position has to be high. The result depends on the magnetic circuit, installation and pickup evidence for the specific model.<\/p>\n<h3>Compare permanent and powered magnets at the same duty<\/h3>\n<p>A permanent magnet is a candidate when it can pick up the required targets throughout the operating range. An electromagnet is worth comparing if a deep load, fast belt or high mount leaves too little capture margin. Request the same target sizes and placements for both quotes. For a powered unit, confirm electrical supply, cooling, installation weight and behavior during shutdown. A permanent unit needs no electrical supply to generate its field. A self-cleaning belt still needs a drive. <a href=\"https:\/\/buntingmagnetics.com\/product\/magnetic-separation\/overband-magnets\" rel=\"nofollow noopener\" target=\"_blank\">Bunting model comparison and operating-height definition<\/a>.<\/p>\n<h3>Match the cleaning method to the iron load<\/h3>\n<p>For recurring iron and continuous removal, compare the <a href=\"https:\/\/www.corvelanmag.com\/products\/overband-magnetic-separator\/\">Corvelan permanent self-cleaning overband separators<\/a>. If iron is occasional and the plant has a safe cleaning procedure, compare the <a href=\"https:\/\/www.corvelanmag.com\/products\/suspended-electromagnetic-separator\/\">Corvelan RCDB manual-clean suspended electromagnet<\/a> at the same conveyor conditions. If deep loads and recurring iron occur together, ask for a self-cleaning electromagnetic configuration. Include the longest or heaviest credible item in the discharge check, even if the smallest critical item sets the pickup requirement.<\/p>\n<\/section>\n\n<section><h2 id=\"feed\">How Can You Reduce Burden Depth Without Losing Throughput?<\/h2>\n<p><strong>Reduce surges or spread the feed across more of the usable belt width before changing conveyor speed.<\/strong> Either change can reduce the deepest part of the bed while maintaining average flow. Check how the change affects the transfer, downstream capacity and iron recovery before you commit.<\/p>\n<h3>Stabilize feed before raising belt speed<\/h3>\n<p>If a feeder releases a slug on each cycle, check whether it can deliver the same tonnage more evenly. If the stream is piled on one side, review the chute or feeder discharge and measure the profile again. A leveler can help in some crossbelt layouts. Give large lumps a clear path and have the engineer assess plugging, wear and spill risk. If the whole belt is already full, consider a wider usable loading area or a different separator station. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-328-Eriez-Suspend-Electromagnet-Hazardous-IOM.pdf#page=7\" rel=\"nofollow noopener\" target=\"_blank\">Eriez SM-328, burden control by installation position<\/a>.<\/p>\n<h3>Recheck the bed when materials change<\/h3>\n<p>For a fixed mass flow and speed, a lower loose bulk density means more volume on the belt. Damp, cohesive feed may also hold small steel pieces more firmly, while open, dry feed may let them move more readily. Check both the loaded profile and how easily the target pulls free. Increasing belt speed can thin the bed, but it also cuts pickup time at a crossbelt magnet and changes the trajectory at the head pulley. Retest at the speed and depth you actually plan to run.<\/p>\n<\/section>\n\n<section><h2 id=\"evidence\">What Evidence Shows a Magnet Can Reach Buried Iron?<\/h2>\n<p><strong>A loaded pickup and discharge test gives the clearest answer for the proposed conveyor. A field map describes magnetic reach, and a pull test gives force for a defined test piece and setup.<\/strong> Use the earlier measurements to make the test representative of the conditions that determine selection.<\/p>\n<h3>Compare field and pull data at named positions<\/h3>\n<figure class=\"article-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-magnetic-separator-gauss-test-20260907-075207-1.webp\" alt=\"Compare field and pull data at named positions\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><\/figure>\n<p>Surface Gauss is a magnetic flux density reading at the measurement point. Ask where readings were taken, which direction the probe measured and whether the points cover the center and loaded edges at working distances. In a pull test, identify the test piece, its orientation, the gap and the force measurement method. Changing the piece or its contact with the surface can change the reading. The way the field changes over distance also affects the pull on steel, which helps explain why two magnets with similar face readings can behave differently at the belt. <a href=\"https:\/\/www.corvelanmag.com\/gauss-vs-pull-force\/\">Corvelan\u2019s guide to Gauss and pull force<\/a>.<\/p>\n<h3>Test the hardest pieces you actually need to catch<\/h3>\n<figure class=\"article-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/magnetic-separator-pull-force-test-1-1.webp\" alt=\"Test the hardest pieces you actually need to catch\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\"><\/figure>\n<p>If crusher protection is the job, agree on representative items with the plant team. A worn tooth may be heavy and awkward to discharge. A short bolt or compact steel fragment buried under the load can be a harder pickup. Include credible positions across the loaded width and depths, and record the orientation where it affects results. Use a supplier- and site-approved setup with safe downstream interception and accounting for each test item. Record whether it was lifted, where it went and whether it stayed in the reject stream.<\/p>\n<\/section>\n\n<section><h2 id=\"troubleshoot\">Why Does an Installed Overband Magnet Miss Iron?<\/h2>\n<p><strong>Use the timing and location of the misses to separate feed problems from pickup and discharge problems.<\/strong> Record when the miss occurs, the target type, the loaded profile, belt speed, and whether any steel falls back after pickup. Those observations tell you what to check first.<\/p>\n<h3>Diagnose misses by where and when they happen<\/h3>\n<div class=\"cl-table\" role=\"region\" aria-label=\"Overband magnet troubleshooting\" tabindex=\"0\">\n<table><thead><tr><th scope=\"col\">What you observe<\/th><th scope=\"col\">What to check first<\/th><th scope=\"col\">How to verify the change<\/th><\/tr><\/thead><tbody>\n<tr><th scope=\"row\">Misses peak during surges<\/th><td>Peak depth, changed belt speed, and whether clearance forced a higher magnet position.<\/td><td>Compare pickup at stable feed and at the approved peak condition.<\/td><\/tr>\n<tr><th scope=\"row\">Most misses occur on one side<\/th><td>Off-center loading, mounting alignment or nearby ferromagnetic components.<\/td><td>Repeat the same target at comparable depth and orientation across the loaded belt.<\/td><\/tr>\n<tr><th scope=\"row\">Pickup falls off under ordinary loading<\/th><td>Check height and target type. For a powered unit, have qualified staff check electrical supply and cooling against the manual.<\/td><td>Restore the approved condition and repeat the same loaded challenge.<\/td><\/tr>\n<tr><th scope=\"row\">Steel lifts but returns to the product<\/th><td>Check the cleaning belt, the clearance it needs while carrying iron, and the reject path or splitter.<\/td><td>Confirm that captured pieces reach the reject bin and stay there.<\/td><\/tr>\n<\/tbody><\/table><\/div>\n<h3>Check whether picked-up metal returns to the stream<\/h3>\n<p>Watch from an approved protected location. Look for steel being knocked loose by the load, a crowded reject chute, or a splitter that sends metal back into the product. New scraping or contact calls for a check of belt tracking, loaded clearance, and buildup before the line returns to service. Before accessing the belt, magnet or chute, follow the site\u2019s isolation procedures and the manufacturer\u2019s instructions. A permanent magnet can still attract steel when the belts are stopped and isolated. For U.S. facilities, check which hazardous-energy control standard applies at the site. The OSHA general industry standard covers applicable servicing and maintenance. <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.147\" rel=\"nofollow noopener\" target=\"_blank\">OSHA 29 CFR 1910.147<\/a>. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez SM-323, installation and warnings<\/a>.<\/p>\n<\/section>\n\n<section><h2 id=\"rfq\">What Should You Put in an RFQ and Acceptance Test?<\/h2>\n<p><strong>Give every supplier the same conveyor geometry, feed envelope and target pieces. Agree on what counts as successful removal before ordering.<\/strong> Two quotes with different height datums, loads or test pieces are hard to compare even when they quote the same belt width.<\/p>\n<h3>Give suppliers the same conveyor and target data<\/h3>\n<ul>\n<li><strong>Conveyor:<\/strong> Belt and loaded width, speed range, incline, trough and idler details, proposed location, available height, nearby steel, and reject space. Add side and cross-section drawings where available.<\/li>\n<li><strong>Feed:<\/strong> Material, loose bulk density, moisture if it varies, normal and peak throughput, normal and peak loaded profiles, and maximum lump size.<\/li>\n<li><strong>Tramp iron:<\/strong> Material, shape, size and mass of the smallest critical and largest credible pieces. Include expected frequency and photos or samples when available.<\/li>\n<li><strong>Scope:<\/strong> Cleaning duty, site electrical and environmental conditions, proposed supports and chute responsibility, test scope, and startup requirements.<\/li>\n<\/ul>\n<p>The Dings RFQ shows how to separate belt, burden and metal inputs. If all you have is a layout and a photo of the problem, send both, label estimates and ask which dimensions the supplier needs before final selection. <a href=\"https:\/\/dingsmagnets.com\/wp-content\/uploads\/2025\/01\/Overhead-Magnet-Selection-Guide-and-General-OH-RFQ-1_25.pdf#page=1\" rel=\"nofollow noopener\" target=\"_blank\">Dings overhead magnet RFQ, input fields and drawings<\/a>.<\/p>\n<h3>Agree on test conditions and acceptance criteria<\/h3>\n<p>Specify the belt speed, magnet setting, representative feed, normal and peak load cases, and target groups. Set the pass criteria and number of trials for each group ahead of time. Count the test pieces reaching the intended reject point and divide by the number introduced in that group. If 9 of 10 test bolts reach the reject bin in one defined condition, the observed delivered recovery for that group is 90%. Keep that result attached to the condition and sample size. Report the center and edge runs separately if one position is critical. Pooling them can hide an at-risk part of the belt. Agree on acceptable product carryover, track anything unaccounted for, and repeat the affected condition after adjustments. Ask which checks can happen at the factory and which need the installed conveyor.<\/p>\n<\/section>\n\n<section data-article-section=\"conclusion\"><h2>Confirm the Operating Conditions Before Ordering<\/h2>\n<p>Start with the peak profile and the most difficult steel target you need to remove. Mark the suspension height, running clearance and target position on the same drawing. Compare the best feasible mounting locations, then choose the configuration that delivers the iron to the reject bin under the agreed conditions.<\/p>\n<\/section>\n<div data-article-section=\"cta\" class=\"cl-cta\"><p><strong>Need to size a magnet for your conveyor?<\/strong> Send your belt width and speed, normal and peak burden depths, and a photo or description of the smallest critical steel piece. Include a layout if you have one. Corvelan can review the configuration and the dimensions needed for a quotation.<\/p><p><a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Send your conveyor details to Corvelan<\/a><\/p><\/div>\n\n<section data-article-section=\"faq\"><h2 id=\"faq\">Frequently Asked Questions<\/h2>\n<div class=\"cl-faq\">\n<details><summary>Where should I measure depth if I can\u2019t access the proposed magnet station?<\/summary><p>Use an approved observation point with the closest comparable belt loading and trough shape. Record it as a provisional measurement. If a transfer, incline, trough transition or splitter changes the feed between locations, confirm the actual profile at the magnet station before approving the installation.<\/p><\/details>\n<details><summary>Should I include the largest rock in my burden measurement?<\/summary><p>Report the normal and peak bed profiles and record occasional protruding rocks separately. The bed profile helps assess buried iron pickup. Protruding lumps also affect physical clearance for the separator and the steel it is carrying away.<\/p><\/details>\n<details><summary>Can one magnet specification cover two materials on the same conveyor?<\/summary><p>Yes, if the operating envelope and accepted tests cover both materials. Supply each material\u2019s density, peak depth, speed and target condition. One material may set the required clearance while a stickier material sets the pickup requirement. Keep the two conditions in the test plan.<\/p><\/details>\n<details><summary>What if the conveyor stops while the magnet is energized?<\/summary><p>Check the approved shutdown and restart sequence with the equipment suppliers and site team. Establish where captured iron will go if the cleaning belt stops or the powered magnet loses its field. Plan who checks the reject path before restart. A permanent magnet remains active with its drive off.<\/p><\/details>\n<details><summary>Can a metal detector replace the overband magnet?<\/summary><p>A detector can signal a stop or trigger a reject device if its sensitivity and response are proven for the target and load. An overband magnet physically removes attractable iron. Where both are used, agree on which metals each device handles and where the detected material goes after an alarm.<\/p><\/details>\n<details><summary>Will an overband magnet remove stainless steel or aluminum?<\/summary><p>Aluminum requires another separation or detection method. Stainless steel response varies with the grade and how it was made. Send an actual sample or alloy details if stainless matters. Where capture is uncertain, verify a separate method for that target.<\/p><\/details>\n<details><summary>What if the existing structure won\u2019t let me lower the magnet?<\/summary><p>Check whether you can spread or stabilize the load, use another position such as a suitable head discharge, or select a magnet with verified pickup at the existing height. Have the site engineer review the loads before moving or replacing the unit.<\/p><\/details>\n<details><summary>Can recovered scrap counts show that capture improved?<\/summary><p>More scrap in the bin shows more pieces were collected. It can also mean more iron entered the conveyor. To compare pickup, use known target counts and comparable feed conditions, and track what reached the bin and what passed downstream.<\/p><\/details>\n<details><summary>What should I check if a new idler or chute was installed?<\/summary><p>Check whether the change added ferromagnetic material near the magnet or altered the belt profile, clearance or reject trajectory. Review the manufacturer\u2019s requirements for nearby components, then repeat the relevant pickup checks at the center and edges.<\/p><\/details>\n<details><summary>How should I compare buying a new magnet with moving the existing one?<\/summary><p>First confirm whether the existing unit can meet the pickup and discharge criteria at a feasible alternative location. Then compare installed costs, including steelwork, electrical work, chute changes and production downtime. If you rent a unit for a short job or trial, hold it to the same pickup and clearance criteria.<\/p><\/details>\n<\/div><\/section>\n\n<\/article>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Where should I measure depth if I can\u2019t access the proposed magnet station?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use an approved observation point with the closest comparable belt loading and trough shape. Record it as a provisional measurement. If a transfer, incline, trough transition or splitter changes the feed between locations, confirm the actual profile at the magnet station before approving the installation.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should I include the largest rock in my burden measurement?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Report the normal and peak bed profiles and record occasional protruding rocks separately. The bed profile helps assess buried iron pickup. Protruding lumps also affect physical clearance for the separator and the steel it is carrying away.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can one magnet specification cover two materials on the same conveyor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, if the operating envelope and accepted tests cover both materials. Supply each material\u2019s density, peak depth, speed and target condition. One material may set the required clearance while a stickier material sets the pickup requirement. Keep the two conditions in the test plan.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What if the conveyor stops while the magnet is energized?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Check the approved shutdown and restart sequence with the equipment suppliers and site team. Establish where captured iron will go if the cleaning belt stops or the powered magnet loses its field. Plan who checks the reject path before restart. A permanent magnet remains active with its drive off.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a metal detector replace the overband magnet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A detector can signal a stop or trigger a reject device if its sensitivity and response are proven for the target and load. An overband magnet physically removes attractable iron. Where both are used, agree on which metals each device handles and where the detected material goes after an alarm.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Will an overband magnet remove stainless steel or aluminum?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Aluminum requires another separation or detection method. Stainless steel response varies with the grade and how it was made. Send an actual sample or alloy details if stainless matters. Where capture is uncertain, verify a separate method for that target.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What if the existing structure won\u2019t let me lower the magnet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Check whether you can spread or stabilize the load, use another position such as a suitable head discharge, or select a magnet with verified pickup at the existing height. Have the site engineer review the loads before moving or replacing the unit.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can recovered scrap counts show that capture improved?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"More scrap in the bin shows more pieces were collected. It can also mean more iron entered the conveyor. To compare pickup, use known target counts and comparable feed conditions, and track what reached the bin and what passed downstream.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What should I check if a new idler or chute was installed?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Check whether the change added ferromagnetic material near the magnet or altered the belt profile, clearance or reject trajectory. Review the manufacturer\u2019s requirements for nearby components, then repeat the relevant pickup checks at the center and edges.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How should I compare buying a new magnet with moving the existing one?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"First confirm whether the existing unit can meet the pickup and discharge criteria at a feasible alternative location. Then compare installed costs, including steelwork, electrical work, chute changes and production downtime. If you rent a unit for a short job or trial, hold it to the same pickup and clearance criteria.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>A deeper conveyor load makes it harder for an overband magnet to lift buried iron out of the material stream. If the magnet must also be raised to clear that load, iron near the belt moves farther from the magnet face. Size the separator for the deepest load you expect it to handle at the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4004,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5201","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5201","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/comments?post=5201"}],"version-history":[{"count":5,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5201\/revisions"}],"predecessor-version":[{"id":6068,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5201\/revisions\/6068"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media\/4004"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media?parent=5201"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/categories?post=5201"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/tags?post=5201"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}