{"id":5527,"date":"2026-11-07T20:33:00","date_gmt":"2026-11-07T12:33:00","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5527"},"modified":"2026-10-30T13:46:26","modified_gmt":"2026-10-30T05:46:26","slug":"cts-ctn-ctb-magnetic-separator","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/de\/cts-ctn-ctb-magnetic-separator\/","title":{"rendered":"CTS vs. CTN vs. CTB: Nass-Trommelmagnetscheider"},"content":{"rendered":"\n<style>\n.corvelan-wet-drum-guide{--article-accent:#404040;--article-soft:#f5f5f4;--article-text:#1f2937;color:var(--article-text);font-family:inherit;font-size:17px;line-height:1.75;display:block;float:none;clear:both;columns:auto;overflow-wrap:break-word}\n.corvelan-wet-drum-guide .article-section,.corvelan-wet-drum-guide .article-intro,.corvelan-wet-drum-guide .article-toc{display:block;float:none;clear:both;columns:auto;box-sizing:border-box;margin:0 0 24px;padding:22px;border:1px solid #d6d3d1;border-radius:16px;background:#fff}\n.corvelan-wet-drum-guide .article-section{border-top:4px solid var(--article-accent);box-shadow:0 2px 8px #00000006}\n.corvelan-wet-drum-guide .article-intro,.corvelan-wet-drum-guide .article-toc{background:var(--article-soft)}\n.corvelan-wet-drum-guide h2,.corvelan-wet-drum-guide h3{color:#111827;line-height:1.3;font-weight:700;overflow-wrap:break-word}\n.corvelan-wet-drum-guide h2{font-size:30px;margin:0 0 18px}\n.corvelan-wet-drum-guide h3{font-size:24px;margin:28px 0 12px}\n.corvelan-wet-drum-guide p{margin:0 0 16px}\n.corvelan-wet-drum-guide strong{font-weight:700}\n.corvelan-wet-drum-guide a{color:#262626;text-decoration:underline;text-underline-offset:3px}\n.corvelan-wet-drum-guide a:focus-visible,.corvelan-wet-drum-guide .table-scroll:focus-visible{outline:3px solid #525252;outline-offset:4px}\n.corvelan-wet-drum-guide ul,.corvelan-wet-drum-guide ol{padding-left:24px;margin:0 0 18px}\n.corvelan-wet-drum-guide li{margin:0 0 10px}\n.corvelan-wet-drum-guide .article-toc li{margin-bottom:8px}\n.corvelan-wet-drum-guide .article-media{display:block;float:none;clear:both;margin:20px 0}\n.corvelan-wet-drum-guide .article-media img{display:block;float:none;max-width:100%;height:auto;margin-inline:auto;border-radius:10px}\n.corvelan-wet-drum-guide .table-scroll{display:block;overflow-x:auto;margin:20px 0;-webkit-overflow-scrolling:touch}\n.corvelan-wet-drum-guide table{border-collapse:collapse;width:100%;min-width:700px;font-size:16px;line-height:1.6}\n.corvelan-wet-drum-guide th,.corvelan-wet-drum-guide td{padding:12px;text-align:left;vertical-align:top;border:1px solid #d6d3d1}\n.corvelan-wet-drum-guide th{background:var(--article-soft);color:#111827;font-weight:700}\n.corvelan-wet-drum-guide tr:nth-child(even) td{background:#fafaf9}\n.corvelan-wet-drum-guide .article-faq h3{border-top:1px solid #d6d3d1;padding-top:22px}\n.corvelan-wet-drum-guide .article-cta{display:inline-block;background:#404040;color:#fff;padding:12px 18px;border-radius:8px;font-weight:700;text-decoration:none}\n.corvelan-wet-drum-guide section{scroll-margin-top:110px}\n.corvelan-wet-drum-guide .article-section>:last-child,.corvelan-wet-drum-guide .article-intro>:last-child{margin-bottom:0}\n@media(max-width:768px){\n.corvelan-wet-drum-guide{font-size:16px}\n.corvelan-wet-drum-guide .article-section,.corvelan-wet-drum-guide .article-intro,.corvelan-wet-drum-guide .article-toc{padding:18px;margin-bottom:18px;border-radius:12px}\n.corvelan-wet-drum-guide .article-section{border-top-width:3px}\n.corvelan-wet-drum-guide h2{font-size:24px}\n.corvelan-wet-drum-guide h3{font-size:20px}\n.corvelan-wet-drum-guide th,.corvelan-wet-drum-guide td{padding:10px}\n.corvelan-wet-drum-guide .article-cta{white-space:normal}\n}\n<\/style>\n<article class=\"corvelan-wet-drum-guide\">\n<div class=\"article-intro\"><p><strong>For strongly magnetic slurry, CTS, CTN and CTB magnetic separators commonly refer to three wet-drum tank arrangements: concurrent, counter-current and semi-counter-current.<\/strong> Start with CTS for coarser recovery work, CTN for fine magnetic recovery where tailings loss matters, and CTB for fine-feed cleaning where grade and recovery both matter. Then compare the actual feed and discharge paths: English tank names vary between manufacturers.<\/p>\n<p>The useful question is how each tank brings your slurry to the drum, carries the captured mineral, and releases the remaining material. Those paths help explain why the same drum size can give different results.<\/p><\/div>\n<nav aria-label=\"In this article\" class=\"article-toc\"><p><strong>In this article<\/strong><\/p><ul><li><a href=\"#code-meanings\">What do CTS, CTN and CTB mean?<\/a><\/li><li><a href=\"#slurry-paths\">How does each tank change the slurry path?<\/a><\/li><li><a href=\"#choose-a-tank\">Which arrangement should you compare first?<\/a><\/li><li><a href=\"#feed-and-loading\">Why can the same tank perform differently as feed changes?<\/a><\/li><li><a href=\"#compare-test-results\">How should CTS, CTN and CTB results be compared?<\/a><\/li><li><a href=\"#replace-a-wet-drum\">What should be compared before replacing an existing wet drum?<\/a><\/li><li><a href=\"#wet-drum-faq\">CTS, CTN and CTB wet drum separator FAQ<\/a><\/li><\/ul><\/nav>\n<section class=\"article-section\" id=\"code-meanings\"><h2>What do CTS, CTN and CTB mean?<\/h2>\n<figure class=\"article-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-wet-drum-magnetic-separator-real-product-20260923.webp\" alt=\"Wet drum separator units with stainless drum shells and motor drives\" width=\"800\" height=\"600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/figure>\n\n<p><strong>In common Chinese wet-drum terminology, CTS means concurrent flow, CTN means counter-current flow, and CTB means semi-counter-current flow. The letters describe the tank arrangement; they do not specify recovery, concentrate grade or magnetic strength.<\/strong><\/p>\n<p>All three use a rotating shell around a stationary magnetic system. The feed is a mixture of solid particles and water, called slurry or pulp. Strongly magnetic particles attach to the shell and travel to the magnetic-product outlet. The remaining slurry leaves through the non-magnetic outlet.<\/p>\n<p>When the magnetic mineral is the valuable product, the magnetic stream is the concentrate. The other stream is the tailings. If your purpose is to remove magnetic contamination from a non-magnetic product, the valuable stream is different, so judge product quality at the appropriate outlet.<\/p>\n<div aria-label=\"Scrollable comparison table\" class=\"table-scroll\" role=\"region\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Common code<\/th><th scope=\"col\">Tank arrangement<\/th><th scope=\"col\">Main flow relationship<\/th><th scope=\"col\">First application to consider<\/th><th scope=\"col\">Main trade-off to examine<\/th><\/tr><\/thead><tbody><tr><td>CTS<\/td><td>Concurrent \/ co-current<\/td><td>Feed and captured magnetic material move in the same general direction through the working area<\/td><td>Coarser, strongly magnetic feed and wet pre-separation<\/td><td>Stable coarse-particle transport versus recovery of the finer fraction<\/td><\/tr><tr><td>CTN<\/td><td>Counter-current<\/td><td>Feed moves against the captured magnetic product; the remaining slurry passes through a longer collection region<\/td><td>Fine magnetic roughing, scavenging and suitable magnetic-medium recovery<\/td><td>Low magnetic loss versus unwanted solids carried into the concentrate<\/td><\/tr><tr><td>CTB<\/td><td>Semi-counter-current<\/td><td>Feed enters below the drum; magnetics follow the shell while the non-magnetic stream moves the other way<\/td><td>Fine, liberated magnetic feed requiring both recovery and concentrate cleaning<\/td><td>Product cleaning versus fine magnetic loss as flow and loading change<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Here, <strong>roughing<\/strong> means the first recovery stage, <strong>cleaning<\/strong> means upgrading the recovered product, and <strong>scavenging<\/strong> means recovering valuable material still left in the tailings. These are jobs in a flowsheet, not three fixed machine models.<\/p>\n<h3>Why do English catalogs use different names?<\/h3>\n<p><strong>Counter-current and counter-rotation labels are manufacturer-specific descriptions, so compare the flow drawing before treating two catalog names as equivalent.<\/strong> For example, <a href=\"https:\/\/ejetmagnet.com\/products\/ctn-wet-drum-magnetic-separator\/\" rel=\"nofollow noopener\" target=\"_blank\">EJET&#8217;s wet-drum page<\/a> calls CTN counter-rotation and CTB counter-current, while <a href=\"https:\/\/www.feistech.com\/permanent-magnetic-drum-separator-p00120p1.html\" rel=\"nofollow noopener\" target=\"_blank\">FeisTech&#8217;s description of the traditional series<\/a> uses counter-current for CTN and semi-counter-current for CTB.<\/p>\n<p>Have the proposed cross-section identify four things: <strong>feed entry, drum rotation, magnetic-product discharge and non-magnetic discharge<\/strong>. Trace the slurry after it reaches the drum as well as the captured particles leaving it. This resolves more ambiguity than matching the English word \u201ccounter-current\u201d between quotations.<\/p>\n<\/section>\n<section class=\"article-section\" id=\"slurry-paths\"><h2>How does each tank change the slurry path?<\/h2>\n<p><strong>The tank changes where particles meet the magnetic field, how far the captured material travels, and where the remaining slurry leaves. Compare those three paths to understand the recovery and cleaning differences.<\/strong><\/p>\n<h3>CTS: slurry and captured magnetics travel together<\/h3>\n<p><strong>A conventional CTS tank feeds slurry in the same general direction as the drum surface carrying the magnetic product.<\/strong> The feed reaches the magnetic working area beneath the drum. Magnetic particles attach to the shell, while the non-magnetic fraction leaves through the tank discharge.<\/p>\n<p>This arrangement is a useful starting point for coarser, strongly magnetic feed because coarse particles need a clear route through the tank. Sediment buildup or a restrictive tailings outlet can disturb that route. On a drawing, look at the feed opening, the clearance below the shell and the non-magnetic outlet together.<\/p>\n<p>CTS is not limited to one named stage. The important question is whether the proposed geometry handles your coarse fraction while meeting the required product quality and magnetic-loss limit.<\/p>\n<h3>CTN: short magnetic-product travel and a longer collection path<\/h3>\n<p><strong>In a conventional CTN tank, captured magnetics move against the incoming feed direction toward a nearby concentrate outlet. The remaining slurry travels farther through the collection region before leaving.<\/strong> This gives uncaptured magnetic particles further opportunity to reach the drum.<\/p>\n<p>The short route to the magnetic outlet helps recovery, but it also gives the captured layer less opportunity to shed entrained waste. Entrained material is non-magnetic material carried along with water or trapped between magnetic particles. A recovery-focused arrangement can therefore need a later cleaning stage.<\/p>\n<p>The same general recovery principle appears in <a href=\"https:\/\/www.eriez.com\/Products\/Magnetic-Separation\/Magnetic-Processing-Concentration\/Magnetic-Separation-Solutions-for-Wet-Minerals-Processing\/Wet-Drum-Separators\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s description of its counter-rotation heavy-media tank<\/a>: material missed near the inlet passes through an additional magnetic collection zone. That is a comparison of the flow principle, rather than a model-code conversion.<\/p>\n<h3>CTB: feed enters below the drum and the streams split<\/h3>\n<p><strong>A conventional CTB tank introduces slurry from below into the separation space. Captured magnetics move with the shell, while the non-magnetic stream travels against that movement toward its outlet.<\/strong> \u201cSemi-counter-current\u201d describes this arrangement; it does not mean half the feed reverses direction or that the machine contains two drums.<\/p>\n<p>Introducing dispersed slurry close to the working zone helps magnetic particles reach the shell. As the magnetic layer travels over successive poles, particle chains can turn and release some trapped waste. The water and tank geometry then provide a route for that waste to leave separately.<\/p>\n<p>This makes CTB worth comparing for fine, well-liberated feed when concentrate quality matters. <strong>Liberated<\/strong> means the valuable magnetic mineral has been freed from the surrounding waste mineral. If both minerals remain locked in the same particle, changing the slurry path cannot separate the two parts of that particle.<\/p>\n<\/section>\n<section class=\"article-section\" id=\"choose-a-tank\"><h2>Which arrangement should you compare first?<\/h2>\n<p><strong>Start with the result your stage must deliver: coarse magnetic recovery, low magnetic loss in tailings, or a cleaner fine concentrate. Then use particle size, liberation and slurry loading to decide whether the starting choice still fits.<\/strong><\/p>\n<h3>Coarser feed and wet pre-separation<\/h3>\n<p><strong>Compare a CTS-style concurrent tank first when strongly magnetic, coarser particles need reliable transport through a wet separation stage.<\/strong> Record the top size as well as the full size distribution. A small coarse fraction can still settle, obstruct a narrow passage or increase wear.<\/p>\n<p>If coarse material accumulates under the drum, establish whether the cause is the feed size, inadequate flow distribution or the outlet geometry. Replacing it with a conventional fine-feed CTN arrangement can make coarse-particle transport worse. Ask for the proposed clearances and discharge route to be matched to the actual size distribution.<\/p>\n<h3>Fine magnetic material left in tailings<\/h3>\n<p><strong>Compare a CTN-style recovery arrangement when fine, strongly magnetic particles are being lost and recovery takes priority over the cleanliness of the first magnetic product.<\/strong> Sample the tailings by size fraction. Losing free magnetic fines calls for a different response from losing coarse particles that contain locked magnetic mineral.<\/p>\n<p>First remove feed surges and uneven distribution. If loss remains under steady loading, compare a longer collection path, more useful drum width or a separate scavenger. Select the option that lowers the measured loss at the required throughput; a change of model letters alone does not establish an improvement.<\/p>\n<h3>Fine concentrate that needs a higher grade<\/h3>\n<p><strong>Compare a CTB-style semi-counter-current arrangement when the feed is fine and sufficiently liberated, and the magnetic product needs both cleaning and strong recovery.<\/strong> Look for removal of free waste particles while tracking how much valuable magnetic material leaves with them.<\/p>\n<p>If microscopy or suitable mineralogical testing shows locked particles, improve liberation or classification before expecting a different tank to raise grade. If the waste is already free, investigate slurry concentration, entrainment and the cleaning action. A cleaner stage can be more useful than forcing one recovery stage to do both jobs.<\/p>\n<p><a href=\"https:\/\/www.metso.com\/portfolio\/lims-magnetic-separators\/\" rel=\"nofollow noopener\" target=\"_blank\">Metso&#8217;s LIMS application guidance<\/a> also separates front-end recovery from final concentrate cleaning, using its own CC, CR and CTC names. The practical lesson is to match the tank to the stage, then identify the physical design behind the name.<\/p>\n<p>For magnetite or ferrosilicon recovery in a dense-media circuit, start from the allowed medium loss and contamination in the recovered medium. Dense-media separation uses a suspension of magnetic particles to make the separating liquid denser. Its recovery drum handles that circulating medium, so an ore-cleaning recommendation cannot simply be copied into the circuit.<\/p>\n<p><strong>Keep an existing separator that already meets the agreed grade, loss and throughput targets.<\/strong> If performance changed after a feed or water-balance change, restore stable conditions and measure the result before replacing the tank. For a weakly magnetic target, investigate a suitable higher-intensity process rather than choosing among these conventional wet-drum codes alone.<\/p>\n<\/section>\n<section class=\"article-section\" id=\"feed-and-loading\"><h2>Why can the same tank perform differently as feed changes?<\/h2>\n<p><strong>A wet drum must handle dry solids, magnetic solids and slurry volume at the same time. Changing one can overload the separator even when the other two appear unchanged.<\/strong><\/p>\n<p>Track these separately:<\/p>\n<ul><li><strong>Dry-solids rate, in t\/h:<\/strong> the mass of all dry material entering each hour.<\/li><li><strong>Magnetic loading, in t\/h:<\/strong> the magnetic portion of those solids that the drum must collect and carry.<\/li><li><strong>Slurry flow, in m\u00b3\/h:<\/strong> the total volume of water and suspended solids passing through the tank.<\/li><\/ul>\n<p>For example, suppose dry-solids feed stays at <strong>20 t\/h<\/strong>. At <strong>40% solids by mass<\/strong>, total slurry mass is 20 \u00f7 0.40 = <strong>50 t\/h<\/strong>, including <strong>30 t\/h of water<\/strong>. Diluting to <strong>30% solids by mass<\/strong> raises total slurry mass to 20 \u00f7 0.30 = <strong>66.67 t\/h<\/strong>, including <strong>46.67 t\/h of water<\/strong>.<\/p>\n<p>You have added <strong>16.67 t\/h of water<\/strong> without reducing dry-solids feed. Dilution may help release free waste, but it also increases hydraulic demand. To obtain slurry volume, divide total slurry mass by the measured slurry density in t\/m\u00b3; slurry metric tons per hour and cubic metres per hour are different quantities.<\/p>\n<p>Likewise, if the magnetic fraction rises from 40% to 60% at the same 20 t\/h dry feed, the potential magnetic load rises from <strong>8 to 12 t\/h<\/strong>. A tank that handles the liquid flow can still lose magnetics if the drum cannot carry that load.<\/p>\n<p>The operating-variable discussion in <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/MMPB-470-Eriez-Wet-Drum-Separator.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez brochure MMPB-470O<\/a> explains how water flow, solids concentration and magnetic loading affect separation. Higher flow changes fluid drag; thicker slurry changes cleaning; excessive magnetic loading increases loss.<\/p>\n<p>Log normal and peak conditions at the separator inlet. If loss rises only during surges, stabilize or redistribute the feed first. If loss remains at steady production, compare the actual hydraulic and magnetic loads with the proposed drum width and tank capacity. This is a stronger basis for resizing than dry t\/h alone.<\/p>\n<\/section>\n<section class=\"article-section\" id=\"compare-test-results\"><h2>How should CTS, CTN and CTB results be compared?<\/h2>\n<p><strong>Compare representative portions of the same feed against the same grade, recovery and throughput requirements. Measure both outlets on a dry-solids basis, and record the settings needed to achieve each result.<\/strong><\/p>\n<ol><li><strong>Define the target and product.<\/strong> State whether the assay measures total iron, magnetic iron, magnetite or another constituent. Use that same constituent throughout the calculation. Total iron recovery and magnetite recovery are different measures.<\/li><li><strong>Prepare comparable feed.<\/strong> Use representative portions of the same material. Record size distribution, feed composition, liberation information and percent solids by mass. Keep the feed mixed so settling does not send coarse material to one trial and fines to another.<\/li><li><strong>Describe each complete arrangement.<\/strong> Record the tank cross-section, useful magnetic width, magnetic system, working arc, drum diameter and speed, tank level, water additions and feed\/discharge positions. Equal rpm on different drum diameters does not give equal shell speed.<\/li><li><strong>Separate screening from optimization.<\/strong> Begin with controlled, comparable feed and loading. Then allow each arrangement suitable adjustments and report those changes. If magnets and drum size also change, describe the result as a comparison of complete machines rather than attributing it all to the tank.<\/li><li><strong>Sample during stable operation.<\/strong> Collect feed, concentrate and tailings over corresponding operating periods. Account for material retained in the tank and any other exits. Determine dry masses and target contents, then reconcile both solids and target mass before trusting recovery.<\/li><li><strong>Test the conditions that could change the choice.<\/strong> Include the required production rate and meaningful feed variation. If losses are concentrated in a particular size fraction, compare that fraction as well as the combined result. Repeat comparable runs to see whether an apparent advantage is larger than normal run-to-run variation.<\/li><\/ol>\n<h3>Worked comparison: higher recovery or a cleaner concentrate?<\/h3>\n<p><strong>Choose the result that meets all agreed product and production requirements. The highest recovery alone can select a concentrate that is too low in grade.<\/strong><\/p>\n<p>Suppose each trial treats <strong>1,000 kg of dry feed containing 40% of the stated target constituent<\/strong>. There are 400 kg of target in the feed. The following two results are assumed to illustrate the calculation; neither is assigned to a tank code.<\/p>\n<div aria-label=\"Scrollable comparison table\" class=\"table-scroll\" role=\"region\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Dry-basis result<\/th><th scope=\"col\">Arrangement A<\/th><th scope=\"col\">Arrangement B<\/th><\/tr><\/thead><tbody><tr><td>Concentrate mass<\/td><td>600 kg<\/td><td>640 kg<\/td><\/tr><tr><td>Concentrate target grade<\/td><td>60%<\/td><td>58%<\/td><\/tr><tr><td>Target in concentrate<\/td><td>600 \u00d7 0.60 = 360 kg<\/td><td>640 \u00d7 0.58 = 371.2 kg<\/td><\/tr><tr><td>Target recovery<\/td><td>360 \u00f7 400 \u00d7 100 = 90%<\/td><td>371.2 \u00f7 400 \u00d7 100 = 92.8%<\/td><\/tr><tr><td>Concentrate mass yield<\/td><td>600 \u00f7 1,000 \u00d7 100 = 60%<\/td><td>640 \u00f7 1,000 \u00d7 100 = 64%<\/td><\/tr><\/tbody><\/table><\/div>\n<p>The general calculation is <strong>target recovery (%) = concentrate dry mass \u00d7 concentrate target fraction \u00f7 (feed dry mass \u00d7 feed target fraction) \u00d7 100<\/strong>. Use fractions such as 0.40 for 40%. The denominator must contain a measured, non-zero target mass.<\/p>\n<p>If the agreed limits are <strong>at least 60% grade and 89% recovery<\/strong>, A meets both and B misses grade. If the grade limit changes to <strong>58%<\/strong>, B also qualifies and recovers <strong>11.2 kg more target per 1,000 kg of feed<\/strong>. Compare throughput, water use and the cost of any further cleaning before choosing B.<\/p>\n<p>For a closed two-product balance, A leaves 400 kg of dry tailings containing 40 kg of target, or <strong>10% tailings grade<\/strong>. B leaves 360 kg containing 28.8 kg of target, or <strong>8% tailings grade<\/strong>. These balances show what the tailings measurements should reconcile with in this example. If measured streams do not close, investigate sampling, moisture correction or retained material before crediting the difference to the tank.<\/p>\n<p>For a multi-stage circuit, calculate overall recovery from the original fresh feed to the final products. Do not count recirculating concentrate as new feed or compare a complete circuit&#8217;s recovery directly with one isolated stage.<\/p>\n<\/section>\n<section class=\"article-section\" id=\"replace-a-wet-drum\"><h2>What should be compared before replacing an existing wet drum?<\/h2>\n<p><strong>Match the proposed tank to the existing slurry circuit and required result before treating it as a replacement. The same drum diameter and nominal capacity do not establish matching connections or flow behavior.<\/strong><\/p>\n<p>Compare the feed-box height and width, operating slurry level, outlet elevations, concentrate and tailings routes, support points, drive side and service access. Include normal and peak slurry flow, dry-solids rate and magnetic loading. A lower outlet or a changed overflow arrangement can alter the surrounding pipework and available gravity head.<\/p>\n<p>Also separate a tank change from a magnetic-system change. The pole arrangement, working arc and relationship between the magnetic system and concentrate outlet affect collection and release. A replacement that changes all of these needs a complete configuration comparison.<\/p>\n<p><a href=\"https:\/\/www.metso.com\/globalassets\/saleshub\/documents---episerver\/lims_iron-ore-technical-datasheet-en.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Metso&#8217;s wet-LIMS technical specification<\/a> describes different feed entries, outlet controls and collection zones for its tank designs. Those are physical differences to resolve on the general arrangement drawing, not just labels on the quotation.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/wet-drum-magnetic-separator\/\">CTS(N.B.) wet drum magnetic separator page<\/a> covers the product family and configuration information. For an existing installation, include the current tank cross-section and inlet\/outlet elevations when comparing a proposed unit.<\/p>\n<p>CTS, CTN and CTB wet drum separators are best compared by <strong>particle path, stage objective and measured product results<\/strong>. Use the common code meanings to start the discussion, then choose the arrangement that meets the required grade, loss and throughput together.<\/p>\n<p>To discuss a configuration with Corvelan, send the material and target mineral, size distribution, normal and peak feed rates, slurry solids concentration, and the result required. For a replacement, add the existing model and available layout information in your inquiry.<\/p>\n<p><a class=\"article-cta\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Discuss Your Wet Drum Configuration<\/a><\/p>\n<\/section>\n<section class=\"article-section article-faq faq\" id=\"wet-drum-faq\"><h2>CTS, CTN and CTB wet drum separator FAQ<\/h2>\n<h3>Are two separators equivalent if drum size and gauss are the same?<\/h3>\n<p><strong>No. Match the tank flow, useful magnetic width, magnetic-field profile and operating load as well as drum dimensions.<\/strong> A surface reading does not describe the field throughout the collection space. Record the measurement position and gap, then compare separation results using the same feed and product requirements. Different outlet arrangements can also prevent a direct replacement.<\/p>\n<h3>Should a dense-media circuit use CTN or CTB?<\/h3>\n<p><strong>Start with a recovery-focused tank, then compare medium loss and recovered-medium contamination under the circuit&#8217;s actual load.<\/strong> A CTN-style arrangement is a useful candidate, and some manufacturers use counter-rotation designs for this job. Ask how the remaining slurry passes through the magnetic collection region. Measure magnetic medium in the non-magnetic discharge and state the loss basis, such as mass per hour or mass per tonne of plant feed; percentages alone can conceal different circulating loads.<\/p>\n<h3>Can a CTN be converted to CTB by reversing the motor?<\/h3>\n<p><strong>Reversing the motor alone does not create a CTB tank.<\/strong> Feed entry, tank geometry, outlet positions and the magnetic system&#8217;s position relative to discharge must suit the intended flow. Start from the existing and proposed cross-sections to identify whether a tank replacement or wider rebuild is needed. Isolate the drive and feed systems before any physical inspection or modification.<\/p>\n<h3>Will changing to CTB solve a high-solids feed problem?<\/h3>\n<p><strong>Only if the proposed arrangement also handles the hydraulic load, solids transport and magnetic loading.<\/strong> Record whether the problem is high solids concentration, high dry t\/h or a high magnetic fraction; these are different conditions. Dilution can improve dispersion while increasing slurry volume. If the resulting flow exceeds the usable tank capacity, more water alone will not solve the problem.<\/p>\n<h3>Are published CTS, CTN and CTB particle-size limits universal?<\/h3>\n<p><strong>No. Use the limits for the exact proposed tank and magnetic system, together with your measured size distribution.<\/strong> Catalogue limits differ with clearances, outlets, magnetic geometry and the duty being described. Ask whether a stated top size applies to all feed solids or only a particular fraction. For a broad feed, include the coarse fraction and fine magnetic losses in the trial instead of relying on an average size.<\/p>\n<h3>Can a high laboratory recovery determine the production model?<\/h3>\n<p><strong>Laboratory recovery helps identify separation potential, but production selection also needs representative hydraulic and magnetic loading.<\/strong> Record the laboratory feed rate, slurry concentration, tank design and sample preparation. A slow batch test cannot establish the capacity of a continuous production tank. Use suitable continuous or production-scale testing to assess the required throughput, peak conditions and product quality before final sizing.<\/p>\n<\/section>\n<\/article><script type=\"application\/ld+json\">{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Are two separators equivalent if drum size and gauss are the same?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Match the tank flow, useful magnetic width, magnetic-field profile and operating load as well as drum dimensions. A surface reading does not describe the field throughout the collection space. Record the measurement position and gap, then compare separation results using the same feed and product requirements. Different outlet arrangements can also prevent a direct replacement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should a dense-media circuit use CTN or CTB?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Start with a recovery-focused tank, then compare medium loss and recovered-medium contamination under the circuit's actual load. A CTN-style arrangement is a useful candidate, and some manufacturers use counter-rotation designs for this job. Ask how the remaining slurry passes through the magnetic collection region. Measure magnetic medium in the non-magnetic discharge and state the loss basis, such as mass per hour or mass per tonne of plant feed; percentages alone can conceal different circulating loads.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a CTN be converted to CTB by reversing the motor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Reversing the motor alone does not create a CTB tank. Feed entry, tank geometry, outlet positions and the magnetic system's position relative to discharge must suit the intended flow. Start from the existing and proposed cross-sections to identify whether a tank replacement or wider rebuild is needed. Isolate the drive and feed systems before any physical inspection or modification.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Will changing to CTB solve a high-solids feed problem?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Only if the proposed arrangement also handles the hydraulic load, solids transport and magnetic loading. Record whether the problem is high solids concentration, high dry t\/h or a high magnetic fraction; these are different conditions. Dilution can improve dispersion while increasing slurry volume. If the resulting flow exceeds the usable tank capacity, more water alone will not solve the problem.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Are published CTS, CTN and CTB particle-size limits universal?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Use the limits for the exact proposed tank and magnetic system, together with your measured size distribution. Catalogue limits differ with clearances, outlets, magnetic geometry and the duty being described. Ask whether a stated top size applies to all feed solids or only a particular fraction. For a broad feed, include the coarse fraction and fine magnetic losses in the trial instead of relying on an average size.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a high laboratory recovery determine the production model?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Laboratory recovery helps identify separation potential, but production selection also needs representative hydraulic and magnetic loading. Record the laboratory feed rate, slurry concentration, tank design and sample preparation. A slow batch test cannot establish the capacity of a continuous production tank. Use suitable continuous or production-scale testing to assess the required throughput, peak conditions and product quality before final sizing.\"\n      }\n    }\n  ]\n}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>For strongly magnetic slurry, CTS, CTN and CTB magnetic separators commonly refer to three wet-drum tank arrangements: concurrent, counter-current and semi-counter-current. Start with CTS for coarser recovery work, CTN for fine magnetic recovery where tailings loss matters, and CTB for fine-feed cleaning where grade and recovery both matter. Then compare the actual feed and discharge [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5527","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5527","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/comments?post=5527"}],"version-history":[{"count":2,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5527\/revisions"}],"predecessor-version":[{"id":5627,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/posts\/5527\/revisions\/5627"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media\/4477"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media?parent=5527"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/categories?post=5527"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/tags?post=5527"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}