{"id":4606,"date":"2026-07-18T09:20:52","date_gmt":"2026-07-18T01:20:52","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?post_type=product&#038;p=4606"},"modified":"2026-09-27T18:23:55","modified_gmt":"2026-09-27T10:23:55","slug":"ljt-b-tramp-metal-detector","status":"publish","type":"product","link":"https:\/\/www.corvelanmag.com\/de\/products\/ljt-b-tramp-metal-detector\/","title":{"rendered":"LJT-B-Fremdmetalldetektor f\u00fcr F\u00f6rderb\u00e4nder"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4606\" class=\"elementor elementor-4606\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f8636fb e-con e-atomic-element e-div-block-base e-default-div e-f8636fb-6cef8be \" data-id=\"f8636fb\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"f8636fb\" data-e-type=\"e-div-block\" data-id=\"f8636fb\">\n    \t\t<div class=\"elementor-element elementor-element-ca52803 elementor-widget elementor-widget-html\" data-id=\"ca52803\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<meta charset=\"utf-8\"><meta content=\"width=device-width,initial-scale=1\" name=\"viewport\"><title>LJT-B Split-Frame Tramp Metal Detector | Corvelan<\/title><meta content=\"Use the LJT-B split-frame tramp metal detector for existing belt conveyors. Review 500\u20132000 mm models, retrofit conditions, belt\/splice effects and detection inputs.\" name=\"description\"><div class=\"coverlan-pdp\">\r\n<style>\r\n.coverlan-pdp{--ink:#15202b;--muted:#5e6a76;--line:#dce2e8;--soft:#f5f7f9;--soft2:#eef3f7;--accent:#123f69;--accent2:#0b2d4b;font-family:Arial,Helvetica,sans-serif;color:var(--ink);line-height:1.65;background:#fff}\r\n.coverlan-pdp *{box-sizing:border-box}.coverlan-pdp section{width:100%;margin:0;background:#fff}.coverlan-pdp .cl-soft{background:var(--soft)}.coverlan-pdp .cl-inner{width:100%;max-width:1400px;margin:0 auto;padding:72px 32px}.coverlan-pdp .cl-hero .cl-inner{padding-top:56px;padding-bottom:56px}.coverlan-pdp h1,.coverlan-pdp h2,.coverlan-pdp h3{line-height:1.18;margin:0 0 18px;color:var(--ink)}.coverlan-pdp h1{font-size:36px;letter-spacing:-.02em}.coverlan-pdp h2{font-size:28px;letter-spacing:-.015em}.coverlan-pdp h3{font-size:20px}.coverlan-pdp p{margin:0 0 16px}.coverlan-pdp ul{margin:0;padding-left:20px}.coverlan-pdp li{margin:7px 0}.coverlan-pdp .cl-eyebrow{font-size:13px;font-weight:700;letter-spacing:.08em;text-transform:uppercase;color:var(--accent);margin-bottom:12px}.coverlan-pdp .cl-lead{font-size:19px;color:#314252;max-width:760px}.coverlan-pdp .cl-note{font-size:14px;color:var(--muted)}.coverlan-pdp .cl-hero-grid{display:grid;grid-template-columns:minmax(0,1.05fr) minmax(360px,.95fr);gap:48px;align-items:center}.coverlan-pdp .cl-media{border:1px solid var(--line);background:#fff;overflow:hidden}.coverlan-pdp img{display:block;max-width:100%;height:auto}.coverlan-pdp .cl-media img{width:100%;aspect-ratio:4\/3;object-fit:contain;background:#fff}.coverlan-pdp .cl-cta-row{display:flex;gap:12px;flex-wrap:wrap;margin-top:28px}.coverlan-pdp .cl-btn{display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:12px 20px;text-decoration:none;font-weight:700;border:1px solid var(--accent);transition:.15s ease}.coverlan-pdp .cl-btn-primary{background:var(--accent);color:#fff}.coverlan-pdp .cl-btn-secondary{background:#fff;color:var(--accent)}.coverlan-pdp .cl-btn:focus{outline:3px solid #8fc5ef;outline-offset:2px}.coverlan-pdp .cl-facts{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px;margin-top:26px}.coverlan-pdp .cl-fact{border-left:3px solid var(--accent);padding:10px 12px;background:var(--soft)}.coverlan-pdp .cl-fact b{display:block;font-size:13px;text-transform:uppercase;letter-spacing:.04em;margin-bottom:3px}.coverlan-pdp .cl-grid-3{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:18px}.coverlan-pdp .cl-grid-2{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:22px}.coverlan-pdp .cl-card{border:1px solid var(--line);padding:24px;background:#fff}.coverlan-pdp .cl-card p:last-child,.coverlan-pdp .cl-card ul:last-child{margin-bottom:0}.coverlan-pdp .cl-answer{font-size:18px;font-weight:700;color:#20394f}.coverlan-pdp .cl-kicker{font-size:14px;font-weight:700;color:var(--accent)}.coverlan-pdp .cl-callout{border-left:4px solid var(--accent);padding:20px 22px;background:var(--soft2);margin-top:24px}.coverlan-pdp .cl-table-wrap{width:100%;overflow-x:auto;border:1px solid var(--line);background:#fff}.coverlan-pdp table{border-collapse:collapse;width:100%;min-width:960px;font-size:14px}.coverlan-pdp th,.coverlan-pdp td{padding:12px 11px;border-bottom:1px solid var(--line);text-align:left;white-space:nowrap}.coverlan-pdp th{background:#eaf0f5;font-weight:700;color:#1e3448}.coverlan-pdp tr:last-child td{border-bottom:0}.coverlan-pdp .cl-badges{display:flex;flex-wrap:wrap;gap:8px;margin-top:18px}.coverlan-pdp .cl-badge{border:1px solid #b7c6d3;background:#fff;padding:5px 9px;font-size:13px}.coverlan-pdp .cl-checks{list-style:none;padding-left:0}.coverlan-pdp .cl-checks li{padding-left:27px;position:relative}.coverlan-pdp .cl-checks li:before{content:\"\u2713\";position:absolute;left:0;top:0;font-weight:700;color:var(--accent)}.coverlan-pdp .cl-caution li:before{content:\"\u2022\"}.coverlan-pdp .cl-midcta{background:var(--accent2);color:#fff}.coverlan-pdp .cl-midcta h2,.coverlan-pdp .cl-midcta p{color:#fff}.coverlan-pdp .cl-midcta .cl-btn{background:#fff;color:var(--accent2);border-color:#fff}.coverlan-pdp details{border-top:1px solid var(--line);padding:16px 0}.coverlan-pdp details:last-child{border-bottom:1px solid var(--line)}.coverlan-pdp summary{cursor:pointer;font-weight:700;font-size:17px;list-style:none}.coverlan-pdp summary::-webkit-details-marker{display:none}.coverlan-pdp summary:after{content:\"+\";float:right;color:var(--accent)}.coverlan-pdp details[open] summary:after{content:\"\u2013\"}.coverlan-pdp details p{margin:12px 0 0;color:#394a59}.coverlan-pdp .cl-final{background:#edf3f7}.coverlan-pdp .cl-rfq{display:grid;grid-template-columns:minmax(0,1.05fr) minmax(320px,.95fr);gap:36px;align-items:start}.coverlan-pdp .cl-step{display:grid;grid-template-columns:42px 1fr;gap:14px;align-items:start}.coverlan-pdp .cl-num{width:42px;height:42px;background:var(--accent);color:#fff;display:flex;align-items:center;justify-content:center;font-weight:700}.coverlan-pdp .cl-small{font-size:13px;color:var(--muted)}\r\n@media(max-width:1024px){.coverlan-pdp .cl-inner{padding:60px 24px}.coverlan-pdp .cl-hero-grid{grid-template-columns:1fr;gap:30px}.coverlan-pdp .cl-hero-grid .cl-media{max-width:760px}.coverlan-pdp .cl-grid-3{grid-template-columns:1fr 1fr}.coverlan-pdp .cl-rfq{grid-template-columns:1fr}}\r\n@media(max-width:767px){.coverlan-pdp .cl-inner{padding:48px 16px}.coverlan-pdp .cl-hero .cl-inner{padding-top:36px;padding-bottom:44px}.coverlan-pdp h1{font-size:30px}.coverlan-pdp h2{font-size:24px}.coverlan-pdp .cl-lead{font-size:17px}.coverlan-pdp .cl-facts,.coverlan-pdp .cl-grid-3,.coverlan-pdp .cl-grid-2{grid-template-columns:1fr}.coverlan-pdp .cl-btn{width:100%}.coverlan-pdp .cl-card{padding:20px}.coverlan-pdp .cl-media img{aspect-ratio:4\/3}.coverlan-pdp table{font-size:13px}}\r\n@media(prefers-reduced-motion:reduce){.coverlan-pdp *{scroll-behavior:auto!important;transition:none!important}}\r\n\r\n.coverlan-pdp .cl-quick-table table{min-width:0;width:100%}.coverlan-pdp .cl-quick-table th,.coverlan-pdp .cl-quick-table td{font-size:15px}.coverlan-pdp .cl-spec-layout>*{min-width:0}.coverlan-pdp .cl-spec-layout{display:grid;grid-template-columns:minmax(360px,.82fr) minmax(0,1.18fr);gap:28px;align-items:start}.coverlan-pdp .cl-spec-layout .cl-media{position:sticky;top:20px}.coverlan-pdp .cl-choice{border-top:4px solid var(--accent)}.coverlan-pdp .cl-inline-note{padding:16px 18px;background:var(--soft2);border-left:3px solid var(--accent);margin-top:18px}.coverlan-pdp .cl-list-title{font-weight:700;margin-bottom:6px;color:#20394f}\r\n@media(max-width:1024px){.coverlan-pdp .cl-spec-layout{grid-template-columns:1fr}.coverlan-pdp .cl-spec-layout .cl-media{position:static;max-width:760px}}\r\n\r\n.coverlan-pdp .cl-fact-table{margin-top:24px;overflow-x:visible}.coverlan-pdp .cl-fact-table table{min-width:0;width:100%;table-layout:fixed}.coverlan-pdp .cl-fact-table th{width:190px;background:#eaf0f5}.coverlan-pdp .cl-fact-table th,.coverlan-pdp .cl-fact-table td{white-space:normal;vertical-align:top}.coverlan-pdp .cl-seo-facts td{font-size:15px}.coverlan-pdp .cl-listed-apps{margin-top:18px}\r\n@media(max-width:767px){.coverlan-pdp .cl-fact-table th{width:38%}.coverlan-pdp .cl-fact-table th,.coverlan-pdp .cl-fact-table td{padding:10px 9px;font-size:13px}}\r\n<\/style>\r\n<section class=\"cl-hero\" id=\"top\"><div class=\"cl-inner\"><div class=\"cl-hero-grid\">\r\n<div><div class=\"cl-eyebrow\">Belt Conveyor Tramp <a href=\"https:\/\/www.corvelanmag.com\/product-category\/metal-detection-equipment\/\">Metal Detection<\/a><\/div><h1>LJT-B Tramp Metal Detector for Belt Conveyors<\/h1>\r\n<p class=\"cl-lead\">Corvelan supplies the LJT-B for bulk-material belt conveyors. It detects unwanted metal, often called tramp metal, before it reaches crushers or other equipment. The split frame can be installed around an existing conveyor without cutting the belt.<\/p>\r\n<div class=\"cl-facts\">\r\n<div class=\"cl-fact\"><b>Application<\/b>Belt-conveyor tramp metal detection before vulnerable downstream machinery.<\/div>\r\n<div class=\"cl-fact\"><b>Model belt widths<\/b>500 to 2000 mm across the LJT-B model range.<\/div>\r\n<div class=\"cl-fact\"><b>How it detects metal<\/b>It checks how the sensor signal changes when metal passes through. The formal method uses phase-shift and correlation detection. Sensitivity is adjustable.<\/div>\r\n<div class=\"cl-fact\"><b>What we need from you<\/b>Belt width, material depth, target metal, belt construction, line layout and required control action.<\/div>\r\n<\/div>\r\n<div class=\"cl-cta-row\"><a class=\"cl-btn cl-btn-primary\" data-cta=\"hero\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Ask Corvelan to Check My LJT-B Setup<\/a><a class=\"cl-btn cl-btn-secondary\" href=\"#models\">Compare LJT-B Models<\/a><\/div>\r\n<\/div>\r\n<div class=\"cl-media\"><img fetchpriority=\"high\" decoding=\"async\" alt=\"LJT-B tramp metal detector frame and control enclosure offered by Coverlan\" fetchpriority=\"high\" height=\"900\" loading=\"eager\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-ljt-b-tramp-metal-detector-hero.webp\" width=\"1200\"><\/div>\r\n<\/div><\/div><\/section><section id=\"what-is\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Quick Answer<\/div><h2>What is the LJT-B tramp metal detector?<\/h2>\r\n<p class=\"cl-answer\">The LJT-B is an industrial <a href=\"\/product-category\/conveyor-metal-detector\/\">belt conveyor metal detector<\/a>. It finds unwanted metal moving with bulk material before that metal reaches equipment that could be damaged.<\/p><div aria-label=\"LJT-B quick facts\" class=\"cl-table-wrap cl-fact-table cl-seo-facts\"><table><tbody><tr><th scope=\"row\">Purpose<\/th><td>Detect tramp metal on belt conveyors before it reaches crushers or other vulnerable downstream equipment.<\/td><\/tr><tr><th scope=\"row\">Equipment role<\/th><td>Industrial conveyor metal detector. It sends a control signal; it does not remove metal by itself.<\/td><\/tr><tr><th scope=\"row\">Listed belt widths<\/th><td>500\u20132000 mm across the LJT-B model range.<\/td><\/tr><tr><th scope=\"row\">Detection setup<\/th><td>Adjustable sensitivity with phase-shift and correlation detection.<\/td><\/tr><tr><th scope=\"row\">Belt splice option<\/th><td>Optional splice detector.<\/td><\/tr><tr><th scope=\"row\">Control response<\/th><td>Electrical output with a 1\u201310 second delayed-release setting.<\/td><\/tr><tr><th scope=\"row\">Installation<\/th><td>Split-frame installation around an existing belt without cutting the belt.<\/td><\/tr><tr><th scope=\"row\">Next step<\/th><td>Send the material, target metal, belt width, material depth, belt construction, line layout and required action.<\/td><\/tr><\/tbody><\/table><\/div>\r\n<p>The detector sends a signal when it sees a metal event. Your line can use that signal to sound an alarm, stop the belt or trigger another action. The LJT-B does not remove metal by itself, so removal needs a separate manual, reject or magnetic-separation method.<\/p>\r\n<\/div><\/section>\r\n<section class=\"cl-soft\" id=\"quick-fit\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Where It Fits<\/div><h2>Where does the LJT-B fit on a conveyor?<\/h2><p class=\"cl-answer cl-fit-lead\">Use the LJT-B when unwanted metal may travel with bulk material on a belt conveyor and could damage crushers or other equipment farther down the line.<\/p>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><h3>Find unwanted metal on the belt<\/h3><p>Use the LJT-B when metal may travel with bulk material on a belt conveyor. The detector can then send a signal for the line to respond.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Protect equipment farther down the line<\/h3><p>Place the detector before crushers or other equipment that metal could damage. This gives the line time to alarm, stop or take another linked action.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Connect detection to the action you need<\/h3><p>Tell us what should happen after detection: alarm, conveyor stop, marker, bypass or another automatic action. Engineers often call this linked control an interlock.<\/p><\/div>\r\n<\/div><p class=\"cl-note cl-listed-apps\">Listed application industries include thermal power, cement, papermaking, mining, forestry, environmental protection and building materials. The setup still needs to match the real conveyor and target metal.<\/p><\/div><\/section>\r\n<section class=\"cl-soft\" id=\"principle\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">How It Works<\/div><h2>How does the LJT-B detect unwanted metal?<\/h2>\r\n<p class=\"cl-answer\">The detector watches the sensor signal while material passes through the sensing area. Metal changes that signal. The controller checks the change with phase-shift and correlation detection, and the sensitivity can be adjusted. It also uses anti-interference processing to reduce unwanted signal effects from nearby sources.<\/p>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">01 \u2014 Sense<\/div><h3>Let the material pass through the sensing area<\/h3><p>The detector frame sits around the belt. Material passes through the area where the detector watches for a metal-related change.<\/p><\/div>\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">02 \u2014 Identify<\/div><h3>Check whether the signal matches a metal event<\/h3><p>The controller compares the signal pattern with a metal event. We then set the working threshold to match your conveyor, material depth and target metal.<\/p><\/div>\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">03 \u2014 Act<\/div><h3>Send the signal to your line control<\/h3><p>When the detector triggers, the controller sends an electrical output to your line. It also has a 1\u201310 second delayed-release setting before the output resets.<\/p><\/div>\r\n<\/div><\/div><\/section>\r\n<section id=\"performance\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">What Affects Detection<\/div><h2>What can change detection sensitivity on your conveyor?<\/h2>\r\n<p class=\"cl-answer\">Belt width tells you which frame size to start with. Actual detection depends on the target metal, material depth, belt construction, conveyed material and nearby equipment.<\/p>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><h3>Target metal<\/h3><p>Tell us what metal object must be detected and the smallest test size you want to use. Its size, shape, material and position can change the signal.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Material depth on the belt<\/h3><p>Tell us the normal and maximum depth of material on the belt. Engineers call this burden depth. A deeper load can make the target harder to detect because the metal sits farther from the sensing area.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Belt construction<\/h3><p>Splices, clips, steel cords and other metal parts in the belt can affect the signal. An optional splice detector is available, so send us the exact belt construction.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Nearby equipment<\/h3><p>Steelwork, motors, cables and magnetic equipment can disturb the signal. Send us the layout so we can check more than just the detector frame size.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Material condition<\/h3><p>Wet material, material that carries electrical current, high mineral content and changing product conditions can affect the signal. If the material is difficult, define the test condition first. Then set the pass\/fail target.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Required action<\/h3><p>Tell us what the line should do after detection. This may be an alarm, stop, marker, bypass or another linked automatic action.<\/p><\/div>\r\n<\/div><\/div><\/section>\r\n<section class=\"cl-soft\" id=\"models\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">LJT-B Model Range<\/div><h2>Start with belt width, then check the space around your conveyor<\/h2>\r\n<p class=\"cl-answer\">The listed LJT-B models cover conveyor belt widths from 500 to 2000 mm. Start with belt width, then use the drawing to check the available mounting space.<\/p>\r\n<div class=\"cl-spec-layout\">\r\n<div><div class=\"cl-table-wrap cl-quick-table\"><table><thead><tr><th>Model<\/th><th>Conveyor belt width<\/th><\/tr><\/thead><tbody><tr><td>LJT-B-5<\/td><td>500 mm<\/td><\/tr><tr><td>LJT-B-6.5<\/td><td>650 mm<\/td><\/tr><tr><td>LJT-B-8<\/td><td>800 mm<\/td><\/tr><tr><td>LJT-B-10<\/td><td>1000 mm<\/td><\/tr><tr><td>LJT-B-12<\/td><td>1200 mm<\/td><\/tr><tr><td>LJT-B-14<\/td><td>1400 mm<\/td><\/tr><tr><td>LJT-B-16<\/td><td>1600 mm<\/td><\/tr><tr><td>LJT-B-18<\/td><td>1800 mm<\/td><\/tr><tr><td>LJT-B-20<\/td><td>2000 mm<\/td><\/tr><\/tbody><\/table><\/div>\r\n<div class=\"cl-inline-note\"><strong>Important:<\/strong> belt width only gives you the starting model. Also check material depth, frame clearance, nearby equipment and the action required after detection.<\/div><\/div>\r\n<div class=\"cl-media\"><img loading=\"lazy\" decoding=\"async\" alt=\"LJT-B conveyor metal detector dimensional drawing for model and installation checks\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-ljt-b-installation-dimension-drawing.webp\" width=\"1200\"><\/div>\r\n<\/div>\r\n<h3 style=\"margin-top:34px\">Detailed dimensions for installation<\/h3>\r\n<p>All values below are in millimetres. Dimensions C and D have Standard and Non-standard values. Corvelan checks which arrangement matches your conveyor before we quote the final setup.<\/p>\r\n<div class=\"cl-table-wrap\"><table><thead><tr><th>Model<\/th><th>Belt width<\/th><th>A<\/th><th>B<\/th><th>C Std.<\/th><th>C Non-std.<\/th><th>D Std.<\/th><th>D Non-std.<\/th><th>E<\/th><th>L1<\/th><th>L<\/th><\/tr><\/thead><tbody><tr><td>LJT-B-5<\/td><td>500<\/td><td>850<\/td><td>690<\/td><td>310<\/td><td>310<\/td><td>480<\/td><td>480<\/td><td>250<\/td><td>320<\/td><td>740<\/td><\/tr><tr><td>LJT-B-6.5<\/td><td>650<\/td><td>1000<\/td><td>840<\/td><td>330<\/td><td>330<\/td><td>500<\/td><td>500<\/td><td>250<\/td><td>320<\/td><td>890<\/td><\/tr><tr><td>LJT-B-8<\/td><td>800<\/td><td>1200<\/td><td>1040<\/td><td>350<\/td><td>350<\/td><td>520<\/td><td>520<\/td><td>250<\/td><td>320<\/td><td>1090<\/td><\/tr><tr><td>LJT-B-10<\/td><td>1000<\/td><td>1400<\/td><td>1220<\/td><td>420<\/td><td>520<\/td><td>610<\/td><td>710<\/td><td>300<\/td><td>370<\/td><td>1290<\/td><\/tr><tr><td>LJT-B-12<\/td><td>1200<\/td><td>1600<\/td><td>1420<\/td><td>470<\/td><td>570<\/td><td>660<\/td><td>760<\/td><td>300<\/td><td>370<\/td><td>1490<\/td><\/tr><tr><td>LJT-B-14<\/td><td>1400<\/td><td>1840<\/td><td>1640<\/td><td>520<\/td><td>620<\/td><td>730<\/td><td>830<\/td><td>300<\/td><td>370<\/td><td>1730<\/td><\/tr><tr><td>LJT-B-16<\/td><td>1600<\/td><td>2040<\/td><td>1840<\/td><td>570<\/td><td>670<\/td><td>780<\/td><td>880<\/td><td>350<\/td><td>420<\/td><td>1930<\/td><\/tr><tr><td>LJT-B-18<\/td><td>1800<\/td><td>2300<\/td><td>2100<\/td><td>630<\/td><td>730<\/td><td>840<\/td><td>940<\/td><td>350<\/td><td>420<\/td><td>2190<\/td><\/tr><tr><td>LJT-B-20<\/td><td>2000<\/td><td>2500<\/td><td>2300<\/td><td>680<\/td><td>780<\/td><td>890<\/td><td>990<\/td><td>350<\/td><td>420<\/td><td>2390<\/td><\/tr><\/tbody><\/table><\/div>\r\n<\/div><\/section>\r\n<section id=\"configuration\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Options &amp; Setup<\/div><h2>What do you need to send for an LJT-B quotation?<\/h2>\r\n<div class=\"cl-grid-2\">\r\n<div class=\"cl-card\"><h3>LJT-B functions already listed for the detector<\/h3><ul class=\"cl-checks\"><li>Adjustable sensitivity<\/li><li>Optional splice detector<\/li><li>Output control function<\/li><li>1\u201310 second delayed-release setting after the electrical output is triggered<\/li><li>Installation around an existing conveyor without cutting the belt (retrofit)<\/li><\/ul><\/div>\r\n<div class=\"cl-card\"><h3>What Corvelan matches to your conveyor<\/h3><ul><li>Target metal and test condition<\/li><li>Normal and maximum material depth<\/li><li>Belt construction, splices and clips<\/li><li>Conveyor speed and material condition<\/li><li>Nearby motors, steelwork and magnetic separators<\/li><li>Alarm, stop, reject or marker action<\/li><li>Power supply, control wiring, enclosure needs and any required standards<\/li><\/ul><\/div>\r\n<\/div>\r\n<div class=\"cl-cta-row\"><a class=\"cl-btn cl-btn-primary\" data-cta=\"mid\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Check My Conveyor Layout<\/a><\/div>\r\n<\/div><\/section>\r\n<section class=\"cl-soft\" id=\"suitability\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Where It Fits<\/div><h2>When does the LJT-B fit, and when should you use another approach?<\/h2>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><h3>The LJT-B is a good starting point when<\/h3><ul class=\"cl-checks\"><li>Bulk material on an existing belt conveyor<\/li><li>Tramp-metal detection before vulnerable downstream equipment<\/li><li>Existing conveyor installation where you do not want to cut the belt<\/li><li>Need for adjustable sensitivity and control output<\/li><\/ul><\/div>\r\n<div class=\"cl-card\"><h3>Send us more detail when<\/h3><ul><li>Very small target metal<\/li><li>Deep or highly variable material depth<\/li><li>Wet, electrically conductive or highly mineralized material<\/li><li>Steel-cord belt or metallic splice\/clip system<\/li><li>Strong nearby magnetic field or dense steel structure<\/li><li>Automatic rejection or a special linked control sequence<\/li><\/ul><\/div>\r\n<div class=\"cl-card\"><h3>Use another method, or combine methods, when<\/h3><ul><li>The detector itself must physically remove metal<\/li><li>The process is not a belt conveyor<\/li><li>A guaranteed detection size is requested without defined test conditions<\/li><li>Required environmental or compliance ratings have not been established for the project<\/li><\/ul><\/div>\r\n<\/div><\/div><\/section><section id=\"detector-vs-separator\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Detector vs. Magnetic Separator<\/div><h2>Do you need a metal detector, a magnetic separator, or both?<\/h2>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card cl-choice\"><h3>Use a metal detector when<\/h3><p>You need to find an unusual metal event and trigger an alarm, conveyor stop, marker or other action before equipment is damaged.<\/p><\/div>\r\n<div class=\"cl-card cl-choice\"><h3>Use magnetic separation when<\/h3><p>You need to keep removing iron or steel pieces that a magnet can capture. Engineers call this ferromagnetic tramp iron. A magnetic separator removes the metal instead of only sending a signal.<\/p><\/div>\r\n<div class=\"cl-card cl-choice\"><h3>Use both when<\/h3><p>You need continuous removal of iron and steel plus another layer of protection for unusual metal events. This can also help with targets the magnetic stage may not remove.<\/p><\/div>\r\n<\/div>\r\n<div class=\"cl-callout\"><strong>Not sure which route fits?<\/strong> Send us the target metal and conveyor layout. We will separate the detection job from the metal-removal job before we quote the equipment.<\/div>\r\n<\/div><\/section>\r\n<section class=\"cl-soft\" id=\"installation\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Installation<\/div><h2>Plan the detector around your conveyor, not as a stand-alone frame<\/h2>\r\n<p class=\"cl-answer\">We check the detector opening, nearby sources of interference and the distance needed for the next action. This helps the detector fit the real conveyor layout.<\/p>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">01 \u2014 Fit<\/div><h3>Match the belt and opening<\/h3><p>Start with belt width, the height and shape of the loaded material, and the space around the conveyor.<\/p><\/div>\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">02 \u2014 Clear<\/div><h3>Check what sits near the detector<\/h3><p>Mark nearby steelwork, motors, cables, splices and magnets on the layout. We use this to check that there is enough space and to look for possible signal interference.<\/p><\/div>\r\n<div class=\"cl-card\"><div class=\"cl-kicker\">03 \u2014 Act<\/div><h3>Leave enough distance for the next action<\/h3><p>The detector must sit far enough before the protected equipment. Engineers call this upstream. The extra distance gives the line time to stop, mark, bypass or reject the metal after detection.<\/p><\/div>\r\n<\/div>\r\n<\/div><\/section>\r\n<section id=\"maintenance\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">After Installation &amp; Safety<\/div><h2>How do you check the detector after installation?<\/h2>\r\n<div class=\"cl-grid-3\">\r\n<div class=\"cl-card\"><h3>Keep the sensing area stable<\/h3><p>Check the mounting, cables and enclosure. Also check whether conveyor changes have added new metalwork, cables or other equipment near the detector.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Test with the metal target you agreed on<\/h3><p>Use the agreed metal target, test position, material depth and expected line response. This makes the final check match the protection job you actually need.<\/p><\/div>\r\n<div class=\"cl-card\"><h3>Remove metal safely<\/h3><p>If the belt stops for manual metal removal, shut down and isolate the conveyor first. Then follow your site lockout procedure before anyone approaches the conveyor or material.<\/p><\/div>\r\n<\/div>\r\n<p class=\"cl-note\" style=\"margin-top:18px\">Need a dust or water protection rating, hazardous-area approval, certification, or a specific electrical standard? Add it to your quotation request. Corvelan will only state requirements that are confirmed for your project.<\/p>\r\n<\/div><\/section>\r\n<section class=\"cl-midcta\"><div class=\"cl-inner\"><h2>Send the conveyor layout before you lock the detector position<\/h2><p>We can check the LJT-B model width, mounting space, nearby interference sources and the required control action together.<\/p><div class=\"cl-cta-row\"><a class=\"cl-btn\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Check My Conveyor Layout<\/a><\/div><\/div><\/section>\r\n<section id=\"support\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Corvelan Engineering Support<\/div><h2>How Corvelan checks your LJT-B setup before quotation<\/h2><p class=\"cl-answer\">We start with the detection job, then match the detector to the conveyor, define the check conditions and confirm the quotation scope.<\/p><div class=\"cl-grid-2\"><div class=\"cl-card\"><div class=\"cl-step\"><div class=\"cl-num\">01<\/div><div><h3>Define the detection job<\/h3><p>Tell us the material, the target metal or test object, and what the line should do after detection.<\/p><\/div><\/div><\/div><div class=\"cl-card\"><div class=\"cl-step\"><div class=\"cl-num\">02<\/div><div><h3>Match the detector to the conveyor<\/h3><p>We check belt width, material depth, belt construction, conveyor speed, nearby equipment and available mounting space.<\/p><\/div><\/div><\/div><div class=\"cl-card\"><div class=\"cl-step\"><div class=\"cl-num\">03<\/div><div><h3>Define the check conditions<\/h3><p>We align the target object, test position, material depth and expected line response so the final check matches the protection job.<\/p><\/div><\/div><\/div><div class=\"cl-card\"><div class=\"cl-step\"><div class=\"cl-num\">04<\/div><div><h3>Confirm the quotation scope<\/h3><p>We confirm the LJT-B model, required options, control needs and any project-specific electrical, environmental or compliance requirement that has been verified.<\/p><\/div><\/div><\/div><\/div><div class=\"cl-grid-2\" style=\"margin-top:22px\"><div class=\"cl-card\"><h3>Send these first<\/h3><ul class=\"cl-checks\"><li>Material and target metal<\/li><li>Belt width and material depth<\/li><li>Conveyor speed<\/li><li>Belt construction and splice type<\/li><li>Required line action<\/li><\/ul><\/div><div class=\"cl-card\"><h3>Add these if available<\/h3><ul class=\"cl-checks\"><li>Conveyor drawing or installation photos<\/li><li>Nearby magnetic or electrical equipment<\/li><li>Space limits and site conditions<\/li><li>Required test method<\/li><li>Required protection rating, certification or electrical standard<\/li><\/ul><\/div><\/div><div class=\"cl-callout\"><p>Corvelan can support OEM project requirements and installation or startup support within the agreed scope. We only state detection limits, ratings, certifications and other project requirements after they are confirmed for the job.<\/p><\/div><\/div><\/section>\r\n<section class=\"cl-soft\" id=\"faq\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">FAQ<\/div><h2>LJT-B Tramp Metal Detector FAQ<\/h2>\r\n<details><summary>What does the LJT-B tramp metal detector detect?<\/summary><p>The LJT-B detects unwanted metal carried on a belt conveyor. Tell us the target metal and smallest test size you need. We do not publish one universal minimum detection size because the result depends on the material, belt and test condition.<\/p><\/details>\r\n<details><summary>Does the LJT-B remove the detected metal?<\/summary><p>No. The LJT-B is a detector and control device. After detection, the line can alarm, stop or trigger another linked action. Physical removal requires a separate manual, reject or magnetic-separation method.<\/p><\/details>\r\n<details><summary>Can the LJT-B be installed on an existing conveyor without cutting the belt?<\/summary><p>Yes. The LJT-B can be installed around an existing belt conveyor without cutting the belt. This type of upgrade is often called a retrofit.<\/p><\/details>\r\n<details><summary>Which conveyor belt widths are covered by the LJT-B model range?<\/summary><p>The listed models cover 500, 650, 800, 1000, 1200, 1400, 1600, 1800 and 2000 mm belt widths. We also check the available mounting space around your conveyor before finalizing the setup.<\/p><\/details>\r\n<details><summary>How do belt splices affect detection?<\/summary><p>Metal splices or clips can affect the detector signal. An optional splice detector is available. Send us the splice or clip type and belt construction so we can include it in the setup.<\/p><\/details>\r\n<details><summary>Can the LJT-B be installed near a magnetic separator?<\/summary><p>Yes, it can be considered on a line that also uses magnetic separation. The spacing, nearby steelwork and magnetic field still need to be checked. Send us the line drawing and equipment spacing with your quotation request.<\/p><\/details>\r\n<details><summary>What should I send for an LJT-B quotation?<\/summary><p>Send the material, target metal, belt width, material depth, conveyor speed, belt construction and splice type. Also include nearby magnetic or electrical equipment, the action you want after detection, available space, drawings or photos, and any environmental or test requirement.<\/p><\/details>\r\n<\/div><\/section>\r\n<section class=\"cl-final\" id=\"rfq\"><div class=\"cl-inner\"><div class=\"cl-rfq\"><div><div class=\"cl-eyebrow\">Quotation Details<\/div><h2>Send Us Your Conveyor and Tramp Metal Details<\/h2><p class=\"cl-lead\">You do not need a finished specification. Send the main conveyor details and the metal you need to detect, and we can start from there.<\/p><div class=\"cl-cta-row\"><a class=\"cl-btn cl-btn-primary\" data-cta=\"final\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Send My Conveyor Details<\/a><\/div><\/div>\r\n<div class=\"cl-card\"><h3>Start with these details<\/h3><ul><li><strong>Material:<\/strong> what is carried on the belt?<\/li><li><strong>Target metal:<\/strong> what object or smallest test size must trigger detection?<\/li><li><strong>Belt width:<\/strong> what is the conveyor belt width?<\/li><li><strong>Material depth:<\/strong> how deep is the material on the belt?<\/li><li><strong>Line condition:<\/strong> speed, belt construction, splice type and nearby equipment.<\/li><li><strong>Required action:<\/strong> alarm, stop, marker, bypass or another output.<\/li><\/ul><p class=\"cl-small\">If available, also send a conveyor drawing or clear installation photos. Add any space limits, site conditions and the test method you want to use.<\/p><\/div>\r\n<\/div><\/div><\/section>\r\n<\/div>\r\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Product\",\"name\":\"LJT-B Tramp Metal Detector\",\"category\":\"Industrial belt conveyor tramp metal detector\",\"description\":\"LJT-B tramp metal detector for belt conveyors with adjustable sensitivity, phase-shift and correlation detection, optional splice detection, output control, 1\u201310 second delayed release and listed models for 500 to 2000 mm belt widths.\"},{\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does the LJT-B tramp metal detector detect?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The LJT-B detects unwanted metal carried on a belt conveyor. Tell us the target metal and smallest test size you need. We do not publish one universal minimum detection size because the result depends on the material, belt and test condition.\"}},{\"@type\":\"Question\",\"name\":\"Does the LJT-B remove the detected metal?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The LJT-B is a detector and control device. After detection, the line can alarm, stop or trigger another linked action. Physical removal requires a separate manual, reject or magnetic-separation method.\"}},{\"@type\":\"Question\",\"name\":\"Can the LJT-B be installed on an existing conveyor without cutting the belt?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The LJT-B can be installed around an existing belt conveyor without cutting the belt. This type of upgrade is often called a retrofit.\"}},{\"@type\":\"Question\",\"name\":\"Which conveyor belt widths are covered by the LJT-B model range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The listed models cover 500, 650, 800, 1000, 1200, 1400, 1600, 1800 and 2000 mm belt widths. We also check the available mounting space around your conveyor before finalizing the setup.\"}},{\"@type\":\"Question\",\"name\":\"How do belt splices affect detection?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Metal splices or clips can affect the detector signal. An optional splice detector is available. Send us the splice or clip type and belt construction so we can include it in the setup.\"}},{\"@type\":\"Question\",\"name\":\"Can the LJT-B be installed near a magnetic separator?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, it can be considered on a line that also uses magnetic separation. The spacing, nearby steelwork and magnetic field still need to be checked. Send us the line drawing and equipment spacing with your quotation request.\"}},{\"@type\":\"Question\",\"name\":\"What should I send for an LJT-B quotation?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Send the material, target metal, belt width, material depth, conveyor speed, belt construction and splice type. Also include nearby magnetic or electrical equipment, the action you want after detection, available space, drawings or photos, and any environmental or test requirement.\"}}]}]}<\/script>\n\n\t\t\t\t<\/div>\n\t\t\n<\/div>\n\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>LJT-B Split-Frame Tramp Metal Detector | Corvelan Belt Conveyor Tramp Metal Detection LJT-B Tramp Metal Detector for Belt Conveyors Corvelan supplies the LJT-B for bulk-material belt conveyors. It detects unwanted metal, often called tramp metal, before it reaches crushers or other equipment. The split frame can be installed around an existing conveyor without cutting the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4179,"parent":0,"menu_order":19,"comment_status":"open","ping_status":"open","template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product-category":[40,42],"class_list":["post-4606","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product-category-conveyor-metal-detector","product-category-metal-detection-equipment"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/product\/4606","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/comments?post=4606"}],"version-history":[{"count":5,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/product\/4606\/revisions"}],"predecessor-version":[{"id":5262,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/product\/4606\/revisions\/5262"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media\/4179"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/media?parent=4606"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/de\/wp-json\/wp\/v2\/product-category?post=4606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}