{"id":5542,"date":"2026-11-11T06:19:40","date_gmt":"2026-11-10T22:19:40","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5542"},"modified":"2026-10-30T13:46:41","modified_gmt":"2026-10-30T05:46:41","slug":"magnetic-separator-capacity-calculation","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/es\/magnetic-separator-capacity-calculation\/","title":{"rendered":"C\u00f3mo calcular la capacidad de un separador magn\u00e9tico"},"content":{"rendered":"\n<style>\n.cap-article{--cap-ink:#20262e;--cap-line:#d9dee3;--cap-soft:#f6f7f9;color:var(--cap-ink);font-family:inherit;font-size:17px;line-height:1.75;overflow-wrap:anywhere;display:block}\n.cap-article .cap-intro,.cap-article .cap-section,.cap-article .cap-nav{display:block;padding:22px;border:1px solid var(--cap-line);border-radius:8px;margin:0 0 22px;background:#fff}\n.cap-article .cap-section:nth-of-type(even){background:var(--cap-soft)}\n.cap-article h2{font-size:28px;line-height:1.3;margin:0 0 20px;scroll-margin-top:100px;color:var(--cap-ink)}\n.cap-article h3{font-size:21px;line-height:1.4;margin:28px 0 12px;scroll-margin-top:100px}\n.cap-article p{margin:0 0 16px}.cap-article p:last-child{margin-bottom:0}\n.cap-article a{color:#174f47;text-decoration:underline;text-underline-offset:3px}.cap-article a:hover{color:#112f2b}\n.cap-article a:focus-visible,.cap-article summary:focus-visible{outline:3px solid #174f47;outline-offset:4px}\n.cap-article ul,.cap-article ol{padding-left:24px;margin:14px 0 20px}.cap-article li{margin:6px 0}\n.cap-article .cap-table-scroll{overflow-x:auto;margin:20px 0;border:1px solid var(--cap-line);border-radius:6px}\n.cap-article table{border-collapse:collapse;width:100%;font-size:16px;line-height:1.55}\n.cap-article th,.cap-article td{padding:13px;text-align:left;vertical-align:top;border-bottom:1px solid var(--cap-line);min-width:145px}\n.cap-article th{background:#e9edef;color:#20262e;font-weight:700}.cap-article tbody tr:last-child td{border-bottom:0}\n.cap-article .cap-media{display:block;clear:both;margin:0 0 22px}.cap-article .cap-media img{display:block;max-width:100%;height:auto;margin:0 auto}\n.cap-article .cap-nav summary,.cap-article .cap-faq-item summary{cursor:pointer;font-weight:700;list-style:none;padding-right:30px;position:relative}\n.cap-article summary::-webkit-details-marker{display:none}.cap-article summary::after{content:\"+\";position:absolute;right:0;top:0}\n.cap-article details[open]>summary::after{content:\"\u2212\"}.cap-article .cap-nav ol{margin-bottom:0}\n.cap-article .cap-faq-item{border-top:1px solid var(--cap-line);padding:18px 0}.cap-article .cap-faq-item p{margin-top:14px}\n@media(max-width:767px){.cap-article .cap-intro,.cap-article .cap-section,.cap-article .cap-nav{padding:18px;margin-bottom:18px}.cap-article h2{font-size:25px}.cap-article h3{font-size:20px}.cap-article th,.cap-article td{padding:11px}}\n<\/style>\n<div class=\"cap-article\">\n<div class=\"cap-intro\"><p><strong>Magnetic separator capacity calculation starts with the amount of material reaching the machine: convert it into volume flow, mass flow, or both. Then find the feed rate at which the separator still meets your iron-removal, recovery or product-quality target.<\/strong> The correct calculation changes with dry bulk material, conveyor tramp iron and mineral slurry.<\/p>\n<p>Start with the feed you actually have. A conveyor carrying 100 tonnes per hour, a wet drum treating 100 cubic meters of slurry per hour, and a drum recovering 100 tonnes of magnetic material per hour describe three different duties.<\/p><\/div>\n<details class=\"cap-nav\"><summary>On this page<\/summary><nav aria-label=\"Article sections\"><ol><li><a href=\"#capacity-values\">Which capacity value should you calculate?<\/a><\/li><li><a href=\"#measurements\">What measurements do you need before calculating?<\/a><\/li><li><a href=\"#dry-feed\">How do you calculate dry-feed capacity?<\/a><\/li><li><a href=\"#overband\">How do you size an overband magnet for a conveyor?<\/a><\/li><li><a href=\"#wet-drum\">How do you calculate wet drum loading?<\/a><\/li><li><a href=\"#peaks-and-circuits\">How do peaks, recirculation and multiple separators change capacity?<\/a><\/li><li><a href=\"#prove-throughput\">How do you prove the calculated throughput is usable?<\/a><\/li><li><a href=\"#improve-capacity\">What should you change when capacity is too low?<\/a><\/li><li><a href=\"#quick-summary\">Quick Summary and Next Step<\/a><\/li><li><a href=\"#capacity-faq\">Magnetic Separator Capacity FAQ<\/a><\/li><\/ol><\/nav><\/details>\n<section class=\"cap-section\" id=\"capacity-values\">\n<h2>Which capacity value should you calculate?<\/h2>\n<p><strong>Calculate the incoming material load first, then state the separation result that must be achieved at that load.<\/strong> Use the following quantities to keep the calculation clear.<\/p>\n<div aria-label=\"Which capacity value should you calculate? table\" class=\"cap-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Quantity<\/th>\n<th>Unit used here<\/th>\n<th>What it tells you<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Bulk volume flow<\/td>\n<td>m\u00b3\/h<\/td>\n<td>Space occupied by dry material passing through the feed system<\/td>\n<\/tr>\n<tr>\n<td>Bulk mass flow<\/td>\n<td>t\/h<\/td>\n<td>Mass of the dry or damp bulk feed; state which basis applies<\/td>\n<\/tr>\n<tr>\n<td>Slurry volume flow<\/td>\n<td>m\u00b3\/h<\/td>\n<td>Combined flow of liquid and suspended solids<\/td>\n<\/tr>\n<tr>\n<td>Dry solids flow<\/td>\n<td>t\/h<\/td>\n<td>Solid material in the slurry, excluding water<\/td>\n<\/tr>\n<tr>\n<td>Magnetic material flow<\/td>\n<td>t\/h<\/td>\n<td>Target magnetic fraction arriving at the separator<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>Here, <strong>t means a metric tonne, equal to 1,000 kg<\/strong>. Keep cubic meters and tonnes separate. To convert between them, use the density of the actual stream:<\/p>\n<p><strong>Mass flow = volume flow \u00d7 density.<\/strong><\/p>\n<p>For dry bulk feed, use bulk density, which includes the air spaces between particles. For slurry, use slurry density, which includes both liquid and solids. The density of a solid mineral grain is a different input.<\/p>\n<p>Suppose two dry feeds both run at 40 t\/h. At bulk densities of 0.80 and 1.60 t\/m\u00b3, their volume flows are <strong>50 and 25 m\u00b3\/h<\/strong>. The lighter feed needs twice the volume handling at the same tonnage. That changes the feeder, flow opening and material layer you need to examine.<\/p>\n<p><a href=\"https:\/\/www.nist.gov\/pml\/special-publication-811\/nist-guide-si-chapter-7-rules-and-style-conventions-expressing-values\" rel=\"nofollow noopener\" target=\"_blank\">NIST&#8217;s guide to expressing quantities<\/a> distinguishes quantities, units and mass fractions. That distinction is especially useful when a specification mixes t\/h, m\u00b3\/h and solids percentages.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"measurements\">\n<h2>What measurements do you need before calculating?<\/h2>\n<p><strong>Measure the normal and peak feed rates, the material condition and the result you need.<\/strong> A daily tonnage alone leaves out the short periods when the separator receives its heaviest load.<\/p>\n<h3 id=\"measurements-1\">Get the feed rate from a weighed quantity and elapsed time<\/h3>\n<p>Use a belt scale, weigh feeder or batch weighing record where one is available. For a measured batch:<\/p>\n<p><strong>Feed rate (t\/h) = batch mass (t) \u00f7 feeding time (h).<\/strong><\/p>\n<p>For example, suppose 320 t reaches the separator during 6.4 hours of actual feeding in an eight-hour shift. The running average is <strong>50 t\/h<\/strong>, while the shift average is 40 t\/h. If a separate one-minute interval delivers 1.1 t, that interval corresponds to <strong>66 t\/h<\/strong>. Size the feed system around the operating pattern, including how long those peaks last.<\/p>\n<p>If you use a stopped-belt sample, isolate and lock out the conveyor before collecting material. Weigh all material from a known belt length. Divide mass by length, multiply by the measured operating belt speed, and convert kg\/s to t\/h by multiplying by 3.6. Never collect a sample by reaching onto a moving belt.<\/p>\n<h3 id=\"measurements-2\">Measure the density in the condition being fed<\/h3>\n<p>For loose bulk density, weigh a known-volume container empty, fill it without deliberate compaction, and weigh it again. Divide the net material mass by the container volume. Repeat with representative portions. If the material settles, segregates or holds moisture differently in production, use a sampling method that captures that condition.<\/p>\n<p>For slurry density, take a representative, well-mixed sample and determine its mass per known volume. Do not substitute the mineral&#8217;s grain density. If the sample settles before measurement, the result can misrepresent the feed.<\/p>\n<h3 id=\"measurements-3\">Record the conditions that change the separation load<\/h3>\n<p>Keep particle-size distribution, moisture, magnetic fraction and feed distribution beside the flow record. For wet duty, also record the solids mass fraction and the water added before the separator. Record normal values and the combinations that occur during production; unrelated maximum values from different days do not automatically describe one real operating case.<\/p>\n<p>Write the required result in measurable terms: residual iron in the clean product, capture of specified iron pieces, target recovery, concentrate grade, or magnetic-medium loss. This is what turns a transport calculation into a separator capacity requirement.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"dry-feed\">\n<h2>How do you calculate dry-feed capacity?<\/h2>\n<p><strong>Calculate the volume carried by the actual material cross-section and travel speed, then multiply by bulk density.<\/strong> This gives the feed load. The drum&#8217;s usable separation rate also depends on the layer, magnetic response and required product result.<\/p>\n<h3 id=\"dry-feed-1\">Convert material flow into tonnes per hour<\/h3>\n<p>For steady material moving at a known speed:<\/p>\n<p><strong>Volume flow = cross-sectional area \u00d7 travel speed.<\/strong><\/p>\n<p>With area A in m\u00b2 and speed v in m\/s, the convenient hourly calculation is:<\/p>\n<p><strong>Qv (m\u00b3\/h) = 3,600 \u00d7 A \u00d7 v.<\/strong><br\/>\n<strong>Qm (t\/h) = Qv \u00d7 \u03c1b<\/strong>, using bulk density \u03c1b in t\/m\u00b3.<\/p>\n<p>If density is entered in kg\/m\u00b3 instead, use <strong>Qm (t\/h) = 3.6 \u00d7 A \u00d7 v \u00d7 \u03c1b<\/strong>. The two versions give the same answer after unit conversion.<\/p>\n<p>On a flat, nearly rectangular layer, approximate A as the <strong>occupied material width \u00d7 average layer depth<\/strong>. On a troughed belt, use the measured loaded cross-section or the conveyor&#8217;s loading geometry. Multiplying the full belt width by the height of the pile&#8217;s center overstates the area.<\/p>\n<p>Consider a dry-feed example with an occupied width of 0.90 m, average depth of 0.025 m, travel speed of 0.40 m\/s and bulk density of 1.20 t\/m\u00b3:<\/p>\n<ul>\n<li>Cross-section: 0.90 \u00d7 0.025 = <strong>0.0225 m\u00b2<\/strong>.<\/li>\n<li>Volume flow: 3,600 \u00d7 0.0225 \u00d7 0.40 = <strong>32.4 m\u00b3\/h<\/strong>.<\/li>\n<li>Mass flow: 32.4 \u00d7 1.20 = <strong>38.88 t\/h<\/strong>.<\/li>\n<\/ul>\n<p>Use the speed of the material at the measured cross-section. Do not substitute the drum&#8217;s shell speed for feeder speed. Material falling onto a drum, slipping across its surface or changing direction needs its own feed measurement.<\/p>\n<h3 id=\"dry-feed-2\">Translate the feed load into a useful drum width<\/h3>\n<p>Where a manufacturer or representative trial provides a capacity per meter of useful drum width, use:<\/p>\n<p><strong>Required useful width = design feed rate \u00f7 applicable capacity per meter.<\/strong><\/p>\n<p>For a sizing exercise, assume the applicable rate is 40 t\/h per meter and the design feed is 66 t\/h. The required useful width is <strong>66 \u00f7 40 = 1.65 m<\/strong>. A useful width of 1.20 m would correspond to 48 t\/h under those same assumed conditions. The 40 t\/h per meter input is an example, not a Corvelan rating.<\/p>\n<p>Match the rate to the same material, size range, moisture, magnetic fraction, drum setup and quality target. Useful magnetic width can differ from overall machine width. Wider equipment only helps when the feeder distributes material across that width.<\/p>\n<p>For our <a href=\"https:\/\/www.corvelanmag.com\/products\/dry-drum-magnetic-separator\/\">dry drum magnetic separators<\/a>, start with the feed load and presentation conditions before choosing the drum configuration. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/SB-345-Eriez-Drum-Separators.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s drum separator brochure<\/a>, especially its separation-variables section, also explains why feed rate, surface speed and particle size must be considered together.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"overband\">\n<h2>How do you size an overband magnet for a conveyor?<\/h2>\n<div class=\"cap-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-rcydc-cross-belt-installed-conveyor.webp\" alt=\"Suspended self-cleaning separator positioned above a conveyor belt\" width=\"752\" height=\"577\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/div>\n<p><strong>Calculate the conveyor load, then use its deepest iron position, belt speed and target iron to select the overband magnet.<\/strong> The full material stream passes beneath the magnet; only the captured iron leaves on the cleaning belt.<\/p>\n<h3 id=\"overband-1\">Use throughput to estimate the material layer<\/h3>\n<p>Suppose your conveyor carries 100 t\/h at a bulk density of 0.80 t\/m\u00b3 and a belt speed of 1.0 m\/s:<\/p>\n<p><strong>Volume flow = 100 \u00f7 0.80 = 125 m\u00b3\/h.<\/strong><br\/>\n<strong>Loaded cross-section = 125 \u00f7 (3,600 \u00d7 1.0) = 0.0347 m\u00b2.<\/strong><\/p>\n<p>If the feed forms a nearly rectangular layer across 0.80 m of occupied width, its average depth is <strong>0.0347 \u00f7 0.80 = 0.0434 m, or about 43 mm<\/strong>. At 150 t\/h with the other inputs unchanged, the average becomes about <strong>65 mm<\/strong>.<\/p>\n<p>That is an average layer estimate. Measure the actual deepest section and the iron position within it. A central pile, a surge or a large piece buried at the bottom can create a more demanding capture condition than the average suggests.<\/p>\n<h3 id=\"overband-2\">Examine speed and depth together<\/h3>\n<p>Increasing belt speed reduces the cross-section needed to carry a fixed tonnage. It also reduces the time that a piece spends beneath the magnetic zone. Slowing the belt gives more exposure time but deepens the layer if tonnage stays constant. Choose the speed and feed depth as a pair, then test the target iron at the demanding positions.<\/p>\n<p>The distance from the magnet face to the deepest target includes the clearance above the material and the depth of that target within the burden. Use our <a href=\"https:\/\/www.corvelanmag.com\/magnetic-separator-working-distance\/\">working-distance guide<\/a> when defining those measurement points.<\/p>\n<h3 id=\"overband-3\">Calculate the captured-metal load separately<\/h3>\n<p>For an illustrative iron mass fraction of 0.15 % in a 100 t\/h stream:<\/p>\n<p><strong>Incoming iron load = 100 \u00d7 0.0015 = 0.15 t\/h = 150 kg\/h.<\/strong><\/p>\n<p>Plan the cleaning belt, collection chute and bin for the expected captured-metal flow, including bursts. A low hourly average can still include a single large piece or a short cluster that is difficult to discharge. Record piece size and frequency alongside kg\/h.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/overband-magnetic-separator\/\">overband magnetic separators<\/a> are selected from conveyor conditions and iron-removal duty. Compare proposals using the same belt loading, target pieces, working distance and installation direction, rather than tonnage alone.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"wet-drum\">\n<h2>How do you calculate wet drum loading?<\/h2>\n<p><strong>Calculate slurry volume, dry solids and magnetic material separately. Then check both hydraulic loading and magnetic loading against the selected drum and tank configuration.<\/strong> These loads can change independently.<\/p>\n<h3 id=\"wet-drum-1\">Calculate the three feed quantities<\/h3>\n<p>Use slurry volume flow Qsl in m\u00b3\/h, measured slurry density \u03c1sl in t\/m\u00b3, solids mass fraction ws, and the magnetic mass fraction of the dry solids xm:<\/p>\n<p><strong>Total slurry mass flow = Qsl \u00d7 \u03c1sl.<\/strong><br\/>\n<strong>Dry solids flow Ms = Qsl \u00d7 \u03c1sl \u00d7 ws.<\/strong><br\/>\n<strong>Magnetic material flow Mm = Ms \u00d7 xm.<\/strong><\/p>\n<p>Enter 30 % as 0.30. A solids mass fraction describes solid mass divided by total slurry mass. A magnetic fraction here describes magnetic material divided by dry solid mass. Neither is a volume fraction, and total iron assay is not automatically the mass fraction of magnetite.<\/p>\n<p>For example, assume Qsl = 180 m\u00b3\/h, \u03c1sl = 1.30 t\/m\u00b3, ws = 0.30 and xm = 0.60:<\/p>\n<div aria-label=\"How do you calculate wet drum loading? table\" class=\"cap-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Calculated load<\/th>\n<th>Calculation<\/th>\n<th>Result<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Total slurry mass<\/td>\n<td>180 \u00d7 1.30<\/td>\n<td>234 t\/h<\/td>\n<\/tr>\n<tr>\n<td>Dry solids<\/td>\n<td>234 \u00d7 0.30<\/td>\n<td>70.2 t\/h<\/td>\n<\/tr>\n<tr>\n<td>Magnetic material<\/td>\n<td>70.2 \u00d7 0.60<\/td>\n<td>42.12 t\/h<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>The equipment request should therefore state <strong>180 m\u00b3\/h of slurry, 70.2 t\/h of dry solids and 42.12 t\/h of magnetic material<\/strong>, along with particle size and the required result. Giving only \u201c70 tonnes per hour\u201d leaves the water load undefined.<\/p>\n<h3 id=\"wet-drum-2\">Check the useful width against both loads<\/h3>\n<p>Hydraulic loading is slurry volume per hour per meter of useful width. Magnetic loading is magnetic mass per hour per meter of useful width. With applicable limits qH and qM:<\/p>\n<p><strong>Width required by slurry flow = Qsl \u00f7 qH.<\/strong><br\/>\n<strong>Width required by magnetics = Mm \u00f7 qM.<\/strong><br\/>\n<strong>Start from the larger width requirement.<\/strong><\/p>\n<p>To demonstrate the arithmetic, assume qH = 150 m\u00b3\/h per meter and qM = 30 t\/h per meter. The example needs 180 \u00f7 150 = <strong>1.20 m<\/strong> for slurry flow and 42.12 \u00f7 30 = <strong>1.404 m<\/strong> for magnetics. The magnetic load controls this calculation. Choose a configuration with sufficient useful width for both loads and the required product result. Those two assumed limits illustrate the method; obtain project values for the actual drum, tank and material.<\/p>\n<p><a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/MMPB-470-Eriez-Wet-Drum-Separator.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s wet drum brochure<\/a> separates hydraulic capacity, solids concentration and ferromagnetic content as operating variables. Our <a href=\"https:\/\/www.corvelanmag.com\/products\/wet-drum-magnetic-separator\/\">wet drum magnetic separator<\/a> page likewise explains the slurry and separation inputs used to choose a configuration.<\/p>\n<h3 id=\"wet-drum-3\">Recalculate after adding water<\/h3>\n<p>Dilution can ease a high-solids condition while raising the volume the tank must handle. In the example, keep dry solids at 70.2 t\/h and reduce the solids mass fraction from 0.30 to 0.20. Total slurry mass must rise from 234 to <strong>351 t\/h<\/strong>. This requires <strong>117 t\/h of added water<\/strong>.<\/p>\n<p>Taking water density as approximately 1 t\/m\u00b3 and assuming additive volumes with no entrained air, the incoming slurry increases from 180 to approximately <strong>297 m\u00b3\/h<\/strong>. Dry solids and magnetic mass are unchanged, but slurry volume rises by <strong>65 %<\/strong>. Recheck hydraulic loading after dilution instead of assuming the original flow still applies.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"peaks-and-circuits\">\n<h2>How do peaks, recirculation and multiple separators change capacity?<\/h2>\n<p><strong>Use the load at the separator&#8217;s own inlet, including returns, and calculate each active machine&#8217;s share.<\/strong> Fresh plant feed, circulating feed and final product output can all have different rates.<\/p>\n<h3 id=\"peaks-and-circuits-1\">Set a design rate from the operating pattern<\/h3>\n<p>Record both peak magnitude and duration. A brief feeder surge may be handled by upstream storage and controlled release. A peak that lasts through normal production needs operating capacity. Set growth allowance separately so it is not confused with today&#8217;s measured peak.<\/p>\n<p>There is no single percentage to add to every magnetic separator calculation. First identify whether the uncertainty is volume, layer depth, solids flow, magnetic load or operating time. Then state the chosen allowance against that quantity and its reason.<\/p>\n<h3 id=\"peaks-and-circuits-2\">Add recirculation on the correct basis<\/h3>\n<p>For a steady circuit where a fraction r of the <strong>total separator feed<\/strong> returns to the same inlet:<\/p>\n<p><strong>Gross separator feed = fresh feed \u00f7 (1 \u2212 r).<\/strong><\/p>\n<p>For 50 t\/h fresh feed and a return fraction of 0.20, gross feed is <strong>62.5 t\/h<\/strong>, including 12.5 t\/h of return. If the return is instead specified as 20 % of fresh feed, gross feed is <strong>60 t\/h<\/strong>. Define the denominator before using a recirculation percentage.<\/p>\n<p>Recalculate the returning stream&#8217;s moisture or slurry water where it differs from the fresh feed. The return can also contain a different magnetic fraction, changing magnetic loading even when total tonnes stay similar.<\/p>\n<h3 id=\"peaks-and-circuits-3\">Separate parallel capacity from stages in series<\/h3>\n<p>Two machines in parallel split the feed. For identical units, an initial count is <strong>design feed \u00f7 usable per-unit rate, rounded up<\/strong>. Then verify the split and each branch&#8217;s loading. Two units each handling 50 t\/h can share 100 t\/h only if the feeder can deliver a suitable share to each. A standby unit contributes when it is brought into operation.<\/p>\n<p>Two drums in series perform successive separation steps. Their nameplate capacities do not add. Calculate the second drum&#8217;s actual inlet: it may receive the first drum&#8217;s concentrate, tailings or full stream, plus any water or recycle added between stages. Choose series stages to achieve the separation result and parallel units to share a load.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"prove-throughput\">\n<h2>How do you prove the calculated throughput is usable?<\/h2>\n<p><strong>Run representative material at defined feed rates and measure the separation result at each rate.<\/strong> The usable rate is the one that meets the required result under the operating conditions you need to handle.<\/p>\n<h3 id=\"prove-throughput-1\">Keep the sample and operating record representative<\/h3>\n<p>Include the size range, moisture, magnetic content and flow behavior expected in production. A clean, hand-picked sample hides the fines, clumps and mixed particles that may control the result. Keep increments from different points in the production period and combine or split them without deliberately selecting the magnetic pieces.<\/p>\n<p>Record the actual feed rate, useful width, feed distribution, machine settings, cleaning condition and sampling duration. For a wet drum, add slurry flow, density, solids mass fraction and water addition. <a href=\"https:\/\/www.eriez.com\/Products\/Sample-Preparation\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s sample preparation range<\/a> includes splitting, sieve analysis and pulp-density equipment that illustrates the separate measurements involved.<\/p>\n<p>Compare stable operating points, then include the demanding normal conditions and expected surges. When moving from a small test to production equipment, preserve comparable loading per useful width and feed presentation as far as the design allows. Feed geometry, drum diameter, tank flow and discharge behavior also need to suit the full-size arrangement.<\/p>\n<h3 id=\"prove-throughput-2\">Calculate recovery and product quality separately<\/h3>\n<p>For mineral recovery, collect feed, magnetic concentrate and tailings over a matched sampling period. Weigh dry solids and analyze the same target constituent in each stream:<\/p>\n<p><strong>Target recovery = (concentrate dry mass \u00d7 concentrate target fraction) \u00f7 (feed dry mass \u00d7 feed target fraction).<\/strong><\/p>\n<p>Suppose a calculation example has 10 t of dry feed containing 20 % target material. It produces 2.2 t of dry concentrate containing 85 % of that same target:<\/p>\n<ul>\n<li>Target entering: 10 \u00d7 0.20 = <strong>2.00 t<\/strong>.<\/li>\n<li>Target in concentrate: 2.2 \u00d7 0.85 = <strong>1.87 t<\/strong>.<\/li>\n<li>Target recovery: 1.87 \u00f7 2.00 = <strong>93.5 %<\/strong>.<\/li>\n<li>Concentrate mass yield: 2.2 \u00f7 10 = <strong>22 %<\/strong>.<\/li>\n<\/ul>\n<p>Recovery and mass yield answer different questions. Compare the <strong>85 % concentrate grade and 93.5 % recovery<\/strong> with the project&#8217;s targets together. More concentrate mass can include more unwanted material rather than more useful recovery.<\/p>\n<p>Reconcile feed mass with both product masses and account for material held inside the machine during the test. If the balance does not reconcile within the agreed measurement uncertainty, investigate sampling, retained material or weighing before accepting the result.<\/p>\n<h3 id=\"prove-throughput-3\">Match the result to an iron-removal job<\/h3>\n<p>For tramp iron, compare captured and remaining targets by the agreed size, type and position. Count-based capture and mass-based removal can differ: catching one heavy bolt can dominate removed mass while small pieces still pass. For fine contamination, analyze representative clean-product samples rather than relying on what is visible in the collection bin.<\/p>\n<p>Also watch the discharge. If the drum separates well but its chute blocks, or the next process cannot accept the product, the line&#8217;s usable output remains below the separator&#8217;s apparent feed capacity.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"improve-capacity\">\n<h2>What should you change when capacity is too low?<\/h2>\n<p><strong>Correct feed presentation or the identified load limit first; add drum area or parallel equipment when the required rate still exceeds the usable range.<\/strong> A larger magnet is not the first answer to every throughput problem.<\/p>\n<div aria-label=\"What should you change when capacity is too low? table\" class=\"cap-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>What you observe<\/th>\n<th>Evidence to collect<\/th>\n<th>First adjustment to try<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Iron passes mainly during dry-feed surges<\/td>\n<td>Peak feed record and deepest layer at the same time<\/td>\n<td>Smooth the feeder output or spread the load across the useful width<\/td>\n<\/tr>\n<tr>\n<td>Material builds up on one side of a drum<\/td>\n<td>Feed distribution across the active face<\/td>\n<td>Correct the chute or feeder distribution before increasing width<\/td>\n<\/tr>\n<tr>\n<td>Wet losses rise after adding dilution water<\/td>\n<td>Slurry volume before and after the addition<\/td>\n<td>Reduce excess water or provide enough hydraulic capacity while retaining suitable solids concentration<\/td>\n<\/tr>\n<tr>\n<td>Wet losses rise with more magnetic material at similar slurry volume<\/td>\n<td>Dry solids flow and magnetic fraction for each operating period<\/td>\n<td>Reduce magnetic loading per unit or increase active drum area<\/td>\n<\/tr>\n<tr>\n<td>Throughput falls as captured metal accumulates<\/td>\n<td>Cleaning interval, discharge condition and removed-metal load<\/td>\n<td>Restore timely cleaning and clear discharge; match the cleaning system to the load<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>After an adjustment, repeat the same feed and product measurements used before it. If smoothing the feed restores the result at the required running rate, retain the equipment and improve feed control. If even distribution still leaves a persistent capacity deficit, compare a wider active zone or parallel units using the applicable loading rates.<\/p>\n<p>If a mineral remains locked inside non-magnetic material, more capacity or a stronger surface field may leave product quality unresolved. Examine liberation and particle-size preparation before treating the issue as a machine-size shortage.<\/p>\n<\/section>\n<section class=\"cap-section\" id=\"quick-summary\">\n<h2>Quick Summary and Next Step<\/h2>\n<p><strong>A useful magnetic separator capacity calculation connects feed quantity to a measured separation result.<\/strong> For dry feed, calculate volume from the material cross-section and speed, then convert it using bulk density. For overband magnets, relate conveyor flow to the deepest target position and metal discharge load. For wet drums, calculate slurry volume, dry solids and magnetic mass separately, then check the controlling load.<\/p>\n<p>Use normal and peak conditions, include return streams, and distinguish parallel machines from stages in series. Finish by measuring product quality, recovery or residual contamination at the proposed operating rate.<\/p>\n<p>To discuss a Corvelan configuration, send us the material, magnetic target, normal and peak throughput, and the result you need. Add bulk density and feed dimensions for dry duty, or slurry flow, density and solids concentration for wet duty. Use our <a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">separation requirement form<\/a> for the initial details, or email calculations and drawings to <a href=\"mailto:sales@corvelanmag.com\">sales@corvelanmag.com<\/a>.<\/p>\n<\/section>\n<section class=\"cap-section faq\" id=\"capacity-faq\">\n<h2>Magnetic Separator Capacity FAQ<\/h2>\n<details class=\"cap-faq-item\"><summary>Does \u201ctph\u201d always mean metric tonnes per hour?<\/summary><p><strong>No. Ask whether the figure uses metric tonnes, US short tons or another ton unit.<\/strong> Keep the original unit beside the source value and convert before comparing proposals. In this article, t\/h always means metric tonnes per hour. A capacity per foot of drum width must also be converted before comparing it with capacity per meter.<\/p><\/details>\n<details class=\"cap-faq-item\"><summary>How do I convert damp feed into dry solids?<\/summary><p><strong>Multiply damp feed mass by one minus the wet-basis moisture fraction.<\/strong> For example, 50 t\/h of damp feed at 8 % wet-basis moisture contains 50 \u00d7 0.92 = <strong>46 t\/h of dry solids<\/strong>. Wet-basis moisture is water mass divided by total damp mass. If the report uses dry-basis moisture, divide damp mass by one plus that moisture fraction instead. State the basis before calculating.<\/p><\/details>\n<details class=\"cap-faq-item\"><summary>Is a ten-minute run enough to accept a capacity figure?<\/summary><p><strong>Only if it represents the operating behavior you need to assess; a short stable run can miss surges, buildup and cleaning cycles.<\/strong> Keep the trial running long enough to include the relevant cycle and collect matched samples. If the material changes across shifts or batches, include those conditions in the test program rather than extending one unchanging sample and assuming it covers them.<\/p><\/details>\n<details class=\"cap-faq-item\"><summary>Can I calculate separator capacity from motor power or Gauss?<\/summary><p><strong>No direct conversion gives usable t\/h from motor kW or a Gauss reading.<\/strong> Power describes the drive or electromagnetic circuit under its stated conditions. Gauss describes magnetic flux density at a measurement point. To determine usable capacity, combine feed loading with the target material, geometry and measured separation result.<\/p><\/details>\n<details class=\"cap-faq-item\"><summary>What if I know slurry density but not the solids mass fraction?<\/summary><p><strong>Measure the solids mass fraction or obtain it from a method suited to the known solids and liquid.<\/strong> For a suitable water-based mineral slurry, weigh a representative sample, dry it using an appropriate laboratory method, and divide dry residue mass by original slurry sample mass. Salts, volatile components and entrained air can affect interpretation; use the process laboratory&#8217;s method for such streams. Slurry density alone cannot identify solids content when the solid and liquid densities are unknown.<\/p><\/details>\n<\/section>\n<\/div>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Does \u201ctph\u201d always mean metric tonnes per hour?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Ask whether the figure uses metric tonnes, US short tons or another ton unit. Keep the original unit beside the source value and convert before comparing proposals. In this article, t\/h always means metric tonnes per hour. A capacity per foot of drum width must also be converted before comparing it with capacity per meter.\"}}, {\"@type\": \"Question\", \"name\": \"How do I convert damp feed into dry solids?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Multiply damp feed mass by one minus the wet-basis moisture fraction. For example, 50 t\/h of damp feed at 8 % wet-basis moisture contains 50 \u00d7 0.92 = 46 t\/h of dry solids . Wet-basis moisture is water mass divided by total damp mass. If the report uses dry-basis moisture, divide damp mass by one plus that moisture fraction instead. State the basis before calculating.\"}}, {\"@type\": \"Question\", \"name\": \"Is a ten-minute run enough to accept a capacity figure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only if it represents the operating behavior you need to assess; a short stable run can miss surges, buildup and cleaning cycles. Keep the trial running long enough to include the relevant cycle and collect matched samples. If the material changes across shifts or batches, include those conditions in the test program rather than extending one unchanging sample and assuming it covers them.\"}}, {\"@type\": \"Question\", \"name\": \"Can I calculate separator capacity from motor power or Gauss?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No direct conversion gives usable t\/h from motor kW or a Gauss reading. Power describes the drive or electromagnetic circuit under its stated conditions. Gauss describes magnetic flux density at a measurement point. To determine usable capacity, combine feed loading with the target material, geometry and measured separation result.\"}}, {\"@type\": \"Question\", \"name\": \"What if I know slurry density but not the solids mass fraction?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Measure the solids mass fraction or obtain it from a method suited to the known solids and liquid. For a suitable water-based mineral slurry, weigh a representative sample, dry it using an appropriate laboratory method, and divide dry residue mass by original slurry sample mass. Salts, volatile components and entrained air can affect interpretation; use the process laboratory's method for such streams. Slurry density alone cannot identify solids content when the solid and liquid densities are unknown.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Magnetic separator capacity calculation starts with the amount of material reaching the machine: convert it into volume flow, mass flow, or both. Then find the feed rate at which the separator still meets your iron-removal, recovery or product-quality target. The correct calculation changes with dry bulk material, conveyor tramp iron and mineral slurry. Start with [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4320,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5542","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/comments?post=5542"}],"version-history":[{"count":1,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5542\/revisions"}],"predecessor-version":[{"id":5630,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5542\/revisions\/5630"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media\/4320"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media?parent=5542"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/categories?post=5542"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/tags?post=5542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}