{"id":5560,"date":"2026-11-15T17:48:48","date_gmt":"2026-11-15T09:48:48","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5560"},"modified":"2026-10-30T13:04:28","modified_gmt":"2026-10-30T05:04:28","slug":"custom-magnetic-separator-specification-changes","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/es\/custom-magnetic-separator-specification-changes\/","title":{"rendered":"\u00bfQu\u00e9 cambios en las especificaciones pueden afectar a un pedido de un separador magn\u00e9tico a medida?"},"content":{"rendered":"\n<style>\n\n.cv-spec-change {color:#152536;font-family:inherit;font-size:17px;line-height:1.75;overflow-wrap:break-word;display:block;}\n.cv-spec-change *, .cv-spec-change *::before, .cv-spec-change *::after {box-sizing:border-box;}\n.cv-spec-change .cv-intro,.cv-spec-change .cv-section,.cv-spec-change .cv-toc {display:block;float:none;clear:both;padding:22px;margin:0 0 24px;border:1px solid #dfe7ee;border-top:4px solid #0b4f8a;border-radius:16px;background:#fff;box-shadow:0 3px 12px rgba(6,43,74,.035);}\n.cv-spec-change .cv-intro,.cv-spec-change .cv-toc {background:#f4f8fb;}\n.cv-spec-change h2 {font-size:30px;line-height:1.3;color:#062b4a;margin:0 0 20px;scroll-margin-top:110px;}\n.cv-spec-change h3 {font-size:24px;line-height:1.35;color:#062b4a;margin:28px 0 12px;scroll-margin-top:110px;}\n.cv-spec-change p {margin:0 0 16px;}\n.cv-spec-change p:last-child {margin-bottom:0;}\n.cv-spec-change ul,.cv-spec-change ol {padding-left:1.4em;margin:0 0 18px;}\n.cv-spec-change li {margin:0 0 10px;}\n.cv-spec-change strong {font-weight:700;}\n.cv-spec-change a {color:#0b4f8a;text-decoration:underline;text-underline-offset:3px;}\n.cv-spec-change a:hover {color:#07385f;}\n.cv-spec-change a:focus-visible,.cv-spec-change summary:focus-visible,.cv-spec-change .cv-table-scroll:focus-visible {outline:3px solid #0b4f8a;outline-offset:4px;}\n.cv-spec-change .cv-media {display:block;float:none;clear:both;margin:0 0 20px;}\n.cv-spec-change .cv-media img {display:block;float:none;max-width:100%;height:auto;margin-inline:auto;border-radius:10px;}\n.cv-spec-change .cv-table-scroll {display:block;overflow-x:auto;margin:18px 0 22px;border:1px solid #dfe7ee;border-radius:10px;}\n.cv-spec-change table {border-collapse:collapse;font:inherit;min-width:600px;}\n.cv-spec-change th,.cv-spec-change td {text-align:left;vertical-align:top;padding:12px 14px;border-bottom:1px solid #dfe7ee;}\n.cv-spec-change th {background:#eaf2f8;color:#062b4a;font-weight:700;}\n.cv-spec-change tbody tr:nth-child(even) {background:#f4f8fb;}\n.cv-spec-change tbody tr:last-child td {border-bottom:0;}\n.cv-spec-change .cv-faq details {padding:15px 0;border-bottom:1px solid #dfe7ee;}\n.cv-spec-change .cv-faq details:last-child {border-bottom:0;}\n.cv-spec-change summary {cursor:pointer;font-weight:700;color:#062b4a;line-height:1.5;}\n.cv-spec-change .cv-faq summary {list-style:none;padding-right:30px;position:relative;}\n.cv-spec-change .cv-faq summary::-webkit-details-marker {display:none;}\n.cv-spec-change .cv-faq summary::after {content:'+';position:absolute;right:0;top:0;font-size:22px;line-height:1.3;}\n.cv-spec-change .cv-faq details[open] summary::after {content:'\u2212';}\n.cv-spec-change .cv-faq details p {margin:14px 0 0;}\n.cv-spec-change .cv-toc ol {margin:14px 0 0;}\n.cv-spec-change .cv-change-button {display:inline-block;background:#0b4f8a;color:#fff;padding:12px 18px;border-radius:8px;text-decoration:none;font-weight:700;white-space:normal;}\n.cv-spec-change .cv-change-button:hover {background:#07385f;color:#fff;}\n@media (max-width:768px) {\n .cv-spec-change {font-size:16px;}\n .cv-spec-change .cv-intro,.cv-spec-change .cv-section,.cv-spec-change .cv-toc {padding:18px;margin-bottom:18px;border-radius:12px;border-top-width:3px;}\n .cv-spec-change h2 {font-size:24px;}\n .cv-spec-change h3 {font-size:20px;}\n .cv-spec-change th,.cv-spec-change td {padding:10px 12px;}\n}\n\n<\/style>\n<div class=\"cv-spec-change\">\n<div class=\"cv-intro\"><p><strong>Custom magnetic separator specification changes can affect the order whenever they change what the machine must separate, how material reaches it, how it fits the line, or how its performance will be accepted.<\/strong> Belt width, maximum material depth, working distance, metal target, cleaning method, power supply, and control interfaces are all worth reporting before the affected work proceeds.<\/p>\n<p>A change request does not always mean a larger magnet or a new machine. It may need a drawing revision, a different component, a new material trial, or no hardware change at all. The useful question is: <strong>which part of the accepted design is affected, and what must be updated before that part is built or tested?<\/strong><\/p><\/div>\n<nav class=\"cv-toc\" aria-label=\"Article sections\"><details><summary>On this page<\/summary><ol><li><a href=\"#changes-to-review\">Which Specification Changes Need a Technical Review?<\/a><\/li><li><a href=\"#conveyor-and-material\">How Do Conveyor and Material Changes Affect Selection?<\/a><\/li><li><a href=\"#installation-cleaning-electrical\">Which Installation, Cleaning, and Electrical Changes Matter?<\/a><\/li><li><a href=\"#detector-changes\">What Changes If a Conveyor Metal Detector Is Included?<\/a><\/li><li><a href=\"#order-stage\">How Does the Order Stage Affect a Specification Change?<\/a><\/li><li><a href=\"#change-request\">What Should You Send With a Specification Change Request?<\/a><\/li><li><a href=\"#revised-acceptance\">How Should the Revised Separator Be Accepted?<\/a><\/li><li><a href=\"#before-approval\">Before You Approve the Revised Order<\/a><\/li><li><a href=\"#specification-change-faqs\">Specification Change FAQs<\/a><\/li><\/ol><\/details><\/nav>\n<section class=\"cv-section\"><h2 id=\"changes-to-review\">Which Specification Changes Need a Technical Review?<\/h2>\n\n\n<p><strong>Report changes to the application, installation, machine configuration, utilities, or acceptance requirements.<\/strong> Compare them with the values in the accepted quotation, specification, and drawing. An unchanged model name does not mean the original selection still covers the new job.<\/p>\n<div aria-label=\"Which Specification Changes Need a Technical Review? table\" class=\"cv-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead><tr><th>What changed?<\/th><th>What it can affect<\/th><th>What needs another look<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Belt width, speed, trough shape, or maximum material depth<\/td><td>Working coverage, target distance, and time available to capture iron<\/td><td>Conveyor section, selected magnet, and removal test conditions<\/td><\/tr>\n<tr><td>Material, bulk density, moisture, particle size, or temperature<\/td><td>Volume flow, flow behavior, magnetic response, wear, and component suitability<\/td><td>Application data, representative sample, feed arrangement, and material ratings<\/td><\/tr>\n<tr><td>Metal type, size, shape, or required separation result<\/td><td>Whether the proposed magnetic system can do the job<\/td><td>Target definition, equipment type, and acceptance method<\/td><\/tr>\n<tr><td>Working height, mounting points, inlet, outlet, or discharge side<\/td><td>Fit, support, material path, and space for removed iron<\/td><td>Layout drawing, interfaces, support loads, and service access<\/td><\/tr>\n<tr><td>Manual cleaning changed to automatic cleaning<\/td><td>Frame, drive, belt, guards, controls, and discharge space<\/td><td>Machine configuration and the items included in the order<\/td><\/tr>\n<tr><td>Voltage, phase, frequency, cooling, or control signals<\/td><td>Electrical components, operating speed, and connection to the line<\/td><td>Electrical schedule, wiring information, and functional checks<\/td><\/tr>\n<tr><td>Environment, coating, inspection, test, or document requirements<\/td><td>Materials, component selection, production sequence, and inspection work<\/td><td>Exact requirement, applicable documents, and revised acceptance scope<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>Separate a simple administrative correction from a technical change. Updating a contact name usually affects documents. Changing the destination can also change the required electrical supply or project documentation. Describe the actual change before deciding that it has no engineering effect.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/faq\/\">magnetic separator FAQ<\/a> explains the starting information for a custom order. Once an order has an accepted specification, keep the old and new values together so the review starts from the same agreed machine.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"conveyor-and-material\">How Do Conveyor and Material Changes Affect Selection?<\/h2>\n\n<p><strong>Revisit selection when a change affects the path, depth, speed, or magnetic response of the material.<\/strong> A machine can still fit the conveyor while facing a different separation task.<\/p>\n<h3 id=\"working-distance-distinguish-belt-height-from-top-clearance\">Working distance: distinguish belt height from top clearance<\/h3>\n<p>For a suspended magnet, record the distance from the agreed magnetic face to the belt and the maximum material depth. The empty space above the material is only part of the distance to a buried iron piece. Put the measurement reference on the section drawing; the outer guard or cleaning belt may not be the magnetic-face reference used for selection.<\/p>\n<p>Suppose a flat-belt section has a magnet-face-to-belt distance of <strong>500 mm<\/strong> and material depth of <strong>200 mm<\/strong>. The clearance above the material is 500 \u2212 200 = <strong>300 mm<\/strong>.<\/p>\n<ul>\n<li><strong>If depth increases to 300 mm and the magnet stays in place:<\/strong> top clearance falls to 200 mm. An iron piece resting at belt level is still 500 mm from the face, but it must move through more material.<\/li>\n<li><strong>If the magnet is raised to preserve 300 mm top clearance:<\/strong> the face-to-belt distance becomes 600 mm. The deepest target is now 100 mm farther away as well.<\/li>\n<\/ul>\n<p>These two changes need different reviews. First compare whether the feed can be spread or limited to the accepted maximum depth. If the new depth is required, review the magnet and installation at that condition. Do not raise it just to clear larger lumps and carry the old removal result forward.<\/p>\n<p>A wider belt needs useful magnetic coverage across the revised material path, including its edges. A faster belt gives moving iron less time in the capture area. Send both changes together with the new feed profile; matching the mounting holes alone does not settle either issue.<\/p>\n<p>For our <a href=\"https:\/\/www.corvelanmag.com\/products\/overband-magnetic-separator\/\">overband magnetic separators<\/a>, send the revised conveyor section with belt width, trough shape, speed, maximum depth, and iron target. The <a href=\"https:\/\/dingsmagnets.com\/wp-content\/uploads\/2025\/01\/Overhead-Magnet-Selection-Guide-and-General-OH-RFQ-1_25.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Dings overhead magnet RFQ form<\/a> also treats these as separate selection inputs.<\/p>\n<h3 id=\"throughput-the-same-tonnes-per-hour-can-mean-more-material-volume\">Throughput: the same tonnes per hour can mean more material volume<\/h3>\n<p><strong>Compare both mass flow and volume flow when the material changes.<\/strong> Bulk density is the mass of material in a given loose volume. Using matching units:<\/p>\n<p><strong>Volume flow (m\u00b3\/h) = mass flow (t\/h) \u00f7 bulk density (t\/m\u00b3).<\/strong><\/p>\n<p>For example, 60 t\/h at 1.5 t\/m\u00b3 is <strong>40 m\u00b3\/h<\/strong>. At 0.75 t\/m\u00b3, the same 60 t\/h is <strong>80 m\u00b3\/h<\/strong>. The line now has twice the volume to handle. It needs another look at feed depth and distribution even though the order still says \u201c60 t\/h.\u201d<\/p>\n<p>Use the bulk density for the new feed condition and record normal flow and short surges separately. If the average rate is unchanged but surges are larger, review the feeder or surge control before assuming a larger separator is the best fix.<\/p>\n<h3 id=\"dry-drums-and-metal-targets-keep-the-separation-result-in-view\">Dry drums and metal targets: keep the separation result in view<\/h3>\n<p><strong>A new feed chute, particle range, moisture level, or metal target can change the result without changing the magnet itself.<\/strong> On a <a href=\"https:\/\/www.corvelanmag.com\/products\/dry-drum-magnetic-separator\/\">dry drum magnetic separator<\/a>, material should reach the useful drum width evenly, and the separated streams need a clear path out.<\/p>\n<p>A relocated inlet may concentrate feed at one end. A changed outlet may restrict the divider between the magnetic and nonmagnetic streams, called the splitter. Correct the feed or discharge arrangement and compare both iron removal and useful product carried into the reject stream. Increasing magnetic strength alone does not address uneven feeding.<\/p>\n<p>The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-340-Eriez-Permanent-Magnetic-Dry-Drum-Separator-IOM1.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez dry drum installation manual, pages 4\u20136<\/a>, links controlled feeding and splitter position to separation. It provides a useful reason to review these interfaces together.<\/p>\n<p>If the new target is smaller, weakly magnetic, or embedded in another particle, send representative pieces and material. If the new requirement includes aluminum or copper, review a suitable detection or nonferrous separation method. A stronger conventional iron-removal magnet does not make those metals ferromagnetic.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"installation-cleaning-electrical\">Which Installation, Cleaning, and Electrical Changes Matter?<\/h2>\n<figure class=\"cv-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-magnetic-pulley-drive-assembly.webp\" alt=\"Magnetic pulley assembly with bearing supports, gearbox and motor\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/figure>\n\n<p><strong>Review any change that moves the machine, changes access or iron discharge, adds moving parts, or alters the electrical or environmental conditions.<\/strong> These changes often involve more than one drawing or component.<\/p>\n<h3 id=\"mounting-direction-and-discharge\">Mounting, direction, and discharge<\/h3>\n<p>Changing from crossbelt to inline installation changes how material passes the magnet and where captured iron leaves. Moving the discharge from one side to the other also affects the drive, guards, collection chute, and access. Mark left and right while looking in a stated direction, such as the main conveyor travel direction.<\/p>\n<p>For mounting changes, send hole centers, available height, nearby steelwork, support details, and the space needed to remove service parts. A support beam added close to the active magnetic area can affect the magnetic arrangement. Review its location before approving the revised layout.<\/p>\n<p>Record who supplies the support frame, collection chute, guards, and site cabling. A revised machine outline should not leave the plant contractor building supports from the previous revision.<\/p>\n<h3 id=\"cleaning-method-and-captured-iron-load\">Cleaning method and captured iron load<\/h3>\n<p><strong>Changing from manual to self-cleaning is a machine configuration change.<\/strong> It can add a cleaning belt, drive, support structure, guarding, and a discharge path. The extra assembly can also change the space between the magnetic circuit and the material.<\/p>\n<p>State why the change is needed: more frequent iron, heavier pieces, fewer permitted cleaning stops, or restricted operator access. Then compare the complete arrangement. If a manual unit still suits the iron load but the cleaning position is inaccessible, a revised access arrangement may solve the problem. If iron arrives often enough to interrupt production, automatic discharge deserves review.<\/p>\n<h3 id=\"power-controls-temperature-and-surroundings\">Power, controls, temperature, and surroundings<\/h3>\n<p><strong>Give voltage, phase, and frequency together, plus the required control signals.<\/strong> A permanent magnet needs no power to create its field, but its drum or self-cleaning belt may still need a motor. An electromagnet can also involve a coil supply, rectifier, and cooling equipment.<\/p>\n<p>A supply change can affect motors, drives, protection, control transformers, and cooling auxiliaries. Ask for the selected components and wiring information to match the revised supply. Electrical changes should be designed and carried out by qualified personnel, rather than treated as a terminal-label change.<\/p>\n<p>For controls, describe what the line must do: permit conveyor start, report belt motion, signal a fault, or stop equipment. State signal type, contact requirements, reset behavior, and which party connects the plant control system.<\/p>\n<p>Report higher material or ambient temperature, washdown, corrosion, outdoor exposure, or a changed hazardous-area requirement. These can affect magnets, insulation, belts, seals, enclosures, and protective finishes. Name the actual requirement and required records so the revised component selection can be checked against it.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"detector-changes\">What Changes If a Conveyor Metal Detector Is Included?<\/h2>\n\n<p><strong>Review the detector and its stop, mark, or reject action whenever the belt, material, target, surrounding structure, or line controls change.<\/strong> A magnetic separator removes magnetically responsive material. A detector identifies metal and sends a signal; the rest of the system must complete the required action.<\/p>\n<p>For <a href=\"https:\/\/www.corvelanmag.com\/product-category\/conveyor-metal-detector\/\">conveyor metal detectors<\/a>, include these items in the same change request:<\/p>\n<ul>\n<li><strong>Belt and opening:<\/strong> revised belt width, material depth, frame clearance, belt construction, and metal clips or splices.<\/li>\n<li><strong>Target and background:<\/strong> required metal type, size, shape, position in the load, and any changed moisture or mineral content.<\/li>\n<li><strong>Surroundings:<\/strong> new steelwork, moving metal, motors, cables, or variable-speed drives near the sensor.<\/li>\n<li><strong>Action after detection:<\/strong> revised belt speed, available distance to the protected machine, control signal, reset method, and responsibility for the conveyor stop circuit.<\/li>\n<\/ul>\n<p>A faster conveyor may still produce an alarm while carrying the metal too far before it stops. Record detection, signal response, and actual stopping travel during the agreed functional test. If stopping travel exceeds the available distance, revisit location, speed, or the stopping arrangement before accepting the system.<\/p>\n<p>The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Metal-Detection\/MM-247-Eriez-MA3500-QM2-Metal-Detector-IOM.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez Metalarm 3500 QM2 manual<\/a> addresses sensor installation, electrical interference, and connection to the conveyor starter separately. That is why an alarm test and a complete line-action test answer different questions.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"order-stage\">How Does the Order Stage Affect a Specification Change?<\/h2>\n\n<p><strong>The same change can be simple before design approval and much more involved after parts have been purchased or built.<\/strong> Ask what has actually been released, ordered, fabricated, assembled, and tested. The order date alone does not show the remaining options.<\/p>\n<div aria-label=\"How Does the Order Stage Affect a Specification Change? table\" class=\"cv-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead><tr><th>Order stage<\/th><th>Practical effect<\/th><th>Useful next action<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Inquiry or quotation<\/td><td>The proposed size, configuration, scope, or price basis may change.<\/td><td>Update the application data and compare the revised quotation before placing the order.<\/td><\/tr>\n<tr><td>Drawing approved or components released<\/td><td>Purchased motors, magnets, belts, or fabricated parts may no longer match.<\/td><td>Identify affected purchase and production items before releasing the revision.<\/td><\/tr>\n<tr><td>Fabrication or assembly underway<\/td><td>A change may require rework, replacement parts, or a different layout.<\/td><td>Compare modifying the current build with keeping the accepted design and changing the site arrangement.<\/td><\/tr>\n<tr><td>Inspection or testing completed<\/td><td>Existing records may cover the old configuration or operating conditions.<\/td><td>Define which checks remain valid and which need repeating after the modification.<\/td><\/tr>\n<tr><td>Shipped or installed<\/td><td>The work may involve site access, lifting, new parts, or return transport.<\/td><td>Use the serial number and as-built records to compare retrofit, return, or replacement options.<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p><strong>Cost and delivery effects need the actual change scope.<\/strong> Relevant items include engineering work, purchased components, recoverable parts, rework, coating, assembly, repeat inspection, packing, and transport. Some can run together; others must wait for an approved drawing or a replacement part. Adding every estimated task duration can overstate the delay, while ignoring a long-lead component can understate it.<\/p>\n<p>Ask for a revised delivery basis that identifies the affected work, component availability, required approval, and any new test or inspection date. Agree the price and schedule effect in writing. No universal surcharge or fixed number of extra days fits every specification change.<\/p>\n<p>If the deadline is tight, compare two concrete options: revise the machine to suit the new conditions, or keep the accepted machine and bring the conveyor or feed back within its accepted conditions. Compare the resulting separation duty, installation work, operating limits, and completion date. Keeping the old machine only helps if the line can actually run that way.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"change-request\">What Should You Send With a Specification Change Request?<\/h2>\n\n<p><strong>Send one clear comparison of the accepted requirement and the new requirement, tied to the order and drawing revision.<\/strong> Include connected changes in the same request so a new belt width is not reviewed against an outdated material depth or support drawing.<\/p>\n<ol>\n<li><strong>Identify the equipment.<\/strong> Give the quotation or order number, machine reference, current specification, and accepted drawing number and revision. For an existing machine, add its serial number.<\/li>\n<li><strong>List old and new values.<\/strong> Include units, measurement references, normal and maximum conditions, and why the change is needed. State which values remain unchanged.<\/li>\n<li><strong>Provide the supporting records.<\/strong> Use a marked-up layout, revised conveyor section, measured interface dimensions, or the new material and metal sample details. Mark unknown values as unknown.<\/li>\n<li><strong>State the timing.<\/strong> Give the required site date and ask which affected parts or activities are already committed. Agree whether those activities should wait for the revision decision.<\/li>\n<li><strong>Close the change in writing.<\/strong> Agree the selected configuration, revised drawings, changed supply items, price and delivery effects, and acceptance checks. Record who approves the revision and when the affected work can resume.<\/li>\n<\/ol>\n<h3 id=\"an-example-of-a-useful-before-and-after-record\">An example of a useful before-and-after record<\/h3>\n<p>Suppose an overband installation is being revised. A short comparison can show the whole geometry change:<\/p>\n<div aria-label=\"What Should You Send With a Specification Change Request? table\" class=\"cv-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead><tr><th>Item<\/th><th>Accepted basis<\/th><th>Requested basis<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Main belt width<\/td><td>1,000 mm<\/td><td>1,200 mm<\/td><\/tr>\n<tr><td>Maximum material depth on a flat belt<\/td><td>200 mm<\/td><td>300 mm<\/td><\/tr>\n<tr><td>Magnetic face to belt surface<\/td><td>500 mm<\/td><td>600 mm proposed to keep 300 mm top clearance<\/td><\/tr>\n<tr><td>Other selection inputs<\/td><td>Accepted belt speed, iron target, and material condition<\/td><td>Unchanged in this example<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>This request affects coverage and target distance together. The response should address both before the new support or magnet is released. If the proposed 600 mm distance cannot meet the target, the next choice is to review another magnetic arrangement or reduce the required depth and height. A drawing that only widens the mounting frame leaves the main question unanswered.<\/p>\n<p>Use a dated revision with changes marked. Keep earlier drawings as history and remove them from active production and installation use. When the purchase order, drawing, and email contain conflicting values, record the resolved requirement in the revised order documents.<\/p>\n<p>Take close measurements only with the conveyor stopped and isolated. Keep loose steel tools away from the magnetic area; switching off a permanent separator&#8217;s drive does not switch off its magnetic field.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"revised-acceptance\">How Should the Revised Separator Be Accepted?<\/h2>\n\n<p><strong>Accept the revised machine against the revised requirement, and repeat the checks affected by the change.<\/strong> Keep valid records for unchanged items. Identify the machine and drawing revision on each new inspection or test record.<\/p>\n<ul>\n<li><strong>Changed dimensions or interfaces:<\/strong> measure the affected mounting points, openings, shaft connections, working-height references, and discharge position against the accepted drawing. Include space for guards and service work.<\/li>\n<li><strong>Changed material or metal target:<\/strong> use representative feed and target pieces. Record material condition, feed rate, maximum depth, speed, target position, and the agreed result.<\/li>\n<li><strong>Changed magnetic requirement:<\/strong> define the measurement point, distance, instrument, and method if a field measurement is included. Match any removal trial to the new target and operating conditions.<\/li>\n<li><strong>Changed cleaning or control system:<\/strong> test the agreed motion, discharge, signal, fault, stop, and reset functions that the revision affects.<\/li>\n<li><strong>Changed documents or protective components:<\/strong> match the supplied records, component identification, and specified finish to the revised order scope.<\/li>\n<\/ul>\n<p>Before a Factory Acceptance Test (FAT), agree the sample or test pieces, operating conditions, number of trials where relevant, pass criteria, and who will witness or record the work. If the factory cannot reproduce a necessary site condition, state which part will be tested at the factory and which will be completed after installation.<\/p>\n<p>Judge the result that matters to the process. For iron removal, record the number or mass of agreed targets introduced and recovered under the defined trial. Use a controlled test arrangement that also accounts for unrecovered targets. For a separation duty, compare the required product quality or recovery and useful material lost into the other stream. A repeat surface Gauss reading alone does not answer a changed product-quality requirement.<\/p>\n<p><strong>If the machine passes at low flow but fails at the revised maximum feed, resolve that difference before accepting the higher-duty claim.<\/strong> Compare feed distribution, depth, target position, and discharge mixing with the test record. If spreading the feed restores the result, correct the feeder or chute. If the required target remains beyond the useful working range, review the magnetic arrangement. Adjustments near moving equipment require a stopped, isolated machine; restore guarding before trial runs.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/quality-control\/\">quality control page<\/a> explains the roles of dimensional checks, magnetic measurements, and material or functional tests. Put the checks needed for the revision into the accepted order scope.<\/p>\n\n<\/section>\n<section class=\"cv-section\"><h2 id=\"before-approval\">Before You Approve the Revised Order<\/h2>\n\n<p><strong>Handle custom magnetic separator specification changes by keeping the application, machine, drawings, and acceptance requirements aligned with the same agreed configuration.<\/strong> Identify the changed inputs, resolve their effect on the selected equipment, and agree the price, delivery, and checks before releasing the affected work.<\/p>\n<p>Send us your order or quotation reference, the accepted drawing revision, and a short old-versus-new comparison. Include the revised material conditions, conveyor data, and installation dimensions that explain the change. We can review the application, equipment configuration, interfaces, and inspection requirements with you.<\/p>\n<p><a class=\"cv-change-button\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Discuss Your Specification Change<\/a><\/p>\n\n<\/section>\n<section class=\"cv-section cv-faq faq\"><h2 id=\"specification-change-faqs\">Specification Change FAQs<\/h2>\n\n<details><summary>We supplied an incorrect site dimension. Can we just correct the drawing?<\/summary><p><strong>Review the corrected dimension against the selected machine before releasing a replacement drawing.<\/strong> Mark the previous value as superseded and provide the measured value with its reference points. A correction to the site data can still affect coverage, working distance, mounting, or parts already in production.<\/p><\/details>\n<details><summary>Can a lower capacity requirement let us use a smaller separator?<\/summary><p><strong>Sometimes, but lower throughput alone does not justify reducing the machine size.<\/strong> Required working distance, belt coverage, target size, lump clearance, and installation still matter. Compare the lower-flow case with those unchanged requirements before resizing.<\/p><\/details>\n<details><summary>Does changing the paint color affect a custom order?<\/summary><p><strong>A color change may only affect finishing, but a changed coating system needs a wider review.<\/strong> State the color and whether corrosion resistance, coating thickness, surface preparation, or required markings also change. Timing matters if the original finish has already been applied.<\/p><\/details>\n<details><summary>Can an equivalent motor, belt, or magnetic component be substituted?<\/summary><p><strong>Review the proposed substitute against the requirements it must meet before accepting it.<\/strong> The same motor power can hide different speed, torque, mounting, or enclosure details. A belt substitute needs suitable dimensions, construction, and temperature resistance. For magnetic components, compare the required working result and agreed measurement conditions, rather than surface Gauss alone. Record any accepted substitution in the order documents.<\/p><\/details>\n<details><summary>What if we do not know the maximum material depth yet?<\/summary><p><strong>Use a clearly stated provisional basis for an early quotation, then obtain the peak operating depth before freezing the final selection.<\/strong> Use existing operating records or a safely obtained conveyor profile that includes normal surges. Record where and how the depth was taken. If the peak exceeds the proposed basis, revise the feed control or separator selection before release.<\/p><\/details>\n<details><summary>Can we change the specification after the separator has shipped?<\/summary><p><strong>A change may still be possible, but start with the serial number, as-built drawings, and exact new requirement.<\/strong> Compare a site retrofit, return modification, or replacement with the available access and shutdown time. Agree the changed parts, responsible installer, tests, costs, and delivery arrangements before modifying the machine.<\/p><\/details>\n\n<\/section>\n<\/div>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"We supplied an incorrect site dimension. Can we just correct the drawing?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Review the corrected dimension against the selected machine before releasing a replacement drawing. Mark the previous value as superseded and provide the measured value with its reference points. A correction to the site data can still affect coverage, working distance, mounting, or parts already in production.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a lower capacity requirement let us use a smaller separator?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Sometimes, but lower throughput alone does not justify reducing the machine size. Required working distance, belt coverage, target size, lump clearance, and installation still matter. Compare the lower-flow case with those unchanged requirements before resizing.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does changing the paint color affect a custom order?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A color change may only affect finishing, but a changed coating system needs a wider review. State the color and whether corrosion resistance, coating thickness, surface preparation, or required markings also change. Timing matters if the original finish has already been applied.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can an equivalent motor, belt, or magnetic component be substituted?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Review the proposed substitute against the requirements it must meet before accepting it. The same motor power can hide different speed, torque, mounting, or enclosure details. A belt substitute needs suitable dimensions, construction, and temperature resistance. For magnetic components, compare the required working result and agreed measurement conditions, rather than surface Gauss alone. Record any accepted substitution in the order documents.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What if we do not know the maximum material depth yet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use a clearly stated provisional basis for an early quotation, then obtain the peak operating depth before freezing the final selection. Use existing operating records or a safely obtained conveyor profile that includes normal surges. Record where and how the depth was taken. If the peak exceeds the proposed basis, revise the feed control or separator selection before release.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can we change the specification after the separator has shipped?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A change may still be possible, but start with the serial number, as-built drawings, and exact new requirement. Compare a site retrofit, return modification, or replacement with the available access and shutdown time. Agree the changed parts, responsible installer, tests, costs, and delivery arrangements before modifying the machine.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Custom magnetic separator specification changes can affect the order whenever they change what the machine must separate, how material reaches it, how it fits the line, or how its performance will be accepted. Belt width, maximum material depth, working distance, metal target, cleaning method, power supply, and control interfaces are all worth reporting before the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4252,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5560","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/comments?post=5560"}],"version-history":[{"count":1,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5560\/revisions"}],"predecessor-version":[{"id":5616,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5560\/revisions\/5616"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media\/4252"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media?parent=5560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/categories?post=5560"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/tags?post=5560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}