{"id":5584,"date":"2026-11-21T17:30:01","date_gmt":"2026-11-21T09:30:01","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5584"},"modified":"2026-10-30T13:06:06","modified_gmt":"2026-10-30T05:06:06","slug":"mixed-magnetite-hematite-ore-beneficiation","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/es\/mixed-magnetite-hematite-ore-beneficiation\/","title":{"rendered":"Mineral mixto de magnetita y hematita: recuperaci\u00f3n del hierro que un circuito de magnetita deja atr\u00e1s"},"content":{"rendered":"\n<style>\n\n.corvelan-ore-article { --ore-accent:#344054; --ore-text:#1d2939; --ore-soft:#f5f6f7; --ore-border:#d0d5dd; color:var(--ore-text); font:inherit; font-size:17px; line-height:1.75; overflow-wrap:anywhere; display:block; float:none; clear:both; columns:auto; }\n.corvelan-ore-article .ore-section, .corvelan-ore-article .ore-intro, .corvelan-ore-article .ore-toc { display:block; float:none; clear:both; box-sizing:border-box; margin:0 0 24px; padding:22px; border:1px solid var(--ore-border); border-radius:16px; background:#fff; }\n.corvelan-ore-article .ore-section { border-top:4px solid var(--ore-accent); box-shadow:0 2px 8px #10182808; scroll-margin-top:110px; }\n.corvelan-ore-article .ore-intro, .corvelan-ore-article .ore-toc { background:var(--ore-soft); }\n.corvelan-ore-article h2 { margin:0 0 18px; font:inherit; font-size:30px; font-weight:700; line-height:1.3; color:var(--ore-text); }\n.corvelan-ore-article h3 { margin:26px 0 12px; font:inherit; font-size:24px; font-weight:700; line-height:1.3; }\n.corvelan-ore-article p { margin:0 0 16px; }\n.corvelan-ore-article p:last-child { margin-bottom:0; }\n.corvelan-ore-article strong { font-weight:700; }\n.corvelan-ore-article ul { margin:0 0 18px; padding-left:24px; }\n.corvelan-ore-article li { margin:0 0 9px; }\n.corvelan-ore-article a { color:var(--ore-accent); text-decoration:underline; text-underline-offset:3px; }\n.corvelan-ore-article a:focus-visible, .corvelan-ore-article .ore-table-scroll:focus-visible { outline:3px solid var(--ore-accent); outline-offset:4px; }\n.corvelan-ore-article .ore-summary-label { font-weight:700; margin:0 0 10px; }\n.corvelan-ore-article .ore-toc ul { margin:0; }\n.corvelan-ore-article .ore-media { display:block; float:none; clear:both; margin:20px 0; }\n.corvelan-ore-article .ore-media img { display:block; float:none; max-width:100%; height:auto; margin-inline:auto; }\n.corvelan-ore-article .ore-table-scroll { display:block; overflow-x:auto; margin:18px 0; }\n.corvelan-ore-article table { border-collapse:collapse; width:100%; min-width:540px; font-size:inherit; line-height:1.65; }\n.corvelan-ore-article th, .corvelan-ore-article td { padding:12px 14px; border:1px solid var(--ore-border); text-align:left; vertical-align:top; }\n.corvelan-ore-article th { background:var(--ore-soft); font-weight:700; }\n.corvelan-ore-article tbody tr:nth-child(even) { background:#fafafa; }\n@media (max-width:768px) {\n .corvelan-ore-article { font-size:16px; }\n .corvelan-ore-article .ore-section, .corvelan-ore-article .ore-intro, .corvelan-ore-article .ore-toc { padding:18px; margin-bottom:18px; border-radius:12px; }\n .corvelan-ore-article .ore-section { border-top-width:3px; }\n .corvelan-ore-article h2 { font-size:24px; }\n .corvelan-ore-article h3 { font-size:20px; }\n}\n<\/style>\n<article class=\"corvelan-ore-article\" lang=\"en\"><div class=\"ore-intro\"><p class=\"ore-summary-label\">Quick Summary<\/p><p><strong>Mixed magnetite hematite ore beneficiation starts by finding which iron minerals remain after magnetite recovery.<\/strong> Keep low-intensity magnetic separation for liberated magnetite. Test a separate recovery step for liberated hematite, and use targeted regrinding when valuable iron is still locked with waste minerals. Choose the added step by the iron that reaches an acceptable final product, its impurities and the cost of handling it.<\/p>\n<p>A magnetite circuit can perform well at its intended job while leaving valuable hematite in its tailings. The first decision is whether that stream contains missed magnetite, recoverable hematite or particles that need more liberation. Those three findings lead to different changes.<\/p>\n<\/div><nav aria-label=\"Article sections\" class=\"ore-toc\"><ul><li><a href=\"#magnetite-and-total-iron\">Why can a magnetite circuit leave so much iron behind?<\/a><\/li><li><a href=\"#measure-tailings\">What should you measure in the magnetite tailings?<\/a><\/li><li><a href=\"#compare-recovery-paths\">Which recovery paths should you compare?<\/a><\/li><li><a href=\"#mixed-ore-study\">What does the published mixed-ore study actually show?<\/a><\/li><li><a href=\"#calculate-final-iron\">How much extra iron reaches a usable final product?<\/a><\/li><li><a href=\"#assess-added-circuit\">When is an added hematite circuit worth taking further?<\/a><\/li><li><a href=\"#equipment-selection\">What should you send us for equipment selection?<\/a><\/li><li><a href=\"#mixed-ore-faq\">Mixed magnetite\u2013hematite ore FAQ<\/a><\/li><\/ul><\/nav><section class=\"ore-section\" id=\"magnetite-and-total-iron\"><h2>Why can a magnetite circuit leave so much iron behind?<\/h2>\n<div class=\"ore-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-wet-drum-magnetic-separator-real-product-20260923.webp\" alt=\"Wet drum separator units with separate drives in a workshop\" width=\"800\" height=\"600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/div>\n<p><strong>A low-intensity circuit mainly recovers strongly magnetic magnetite; its magnetite recovery does not describe the recovery of all iron in a mixed ore.<\/strong> Hematite responds much less strongly. Iron in other minerals or locked particles adds another part of the loss.<\/p>\n<p>Low-intensity magnetic separation, or LIMS, uses that strong magnetic response to pull magnetite from the slurry. The material leaving the magnetic product outlet is called concentrate. The other stream is often called non-magnetic tailings, even though it can still contain weakly magnetic iron minerals.<\/p>\n<p>Suppose magnetite carries 60% of the iron in your feed, and the circuit recovers 95% of that magnetite-hosted iron. If no iron from other minerals enters the product, total iron recovery is <strong>60% \u00d7 95% = 57%<\/strong>. The drum has recovered most of its intended target, but 43% of the feed iron remains outside the concentrate.<\/p>\n<p>The distinction matters when an ore blend becomes more oxidized. A lower share of iron in magnetite can reduce total iron recovery without a mechanical failure in the drum. Increasing the field on the existing unit is then a different proposal from adding a process suited to hematite.<\/p>\n<p>Start with <strong>the share of feed iron carried by each mineral<\/strong>, rather than the mineral percentages alone. A mineral&#8217;s share of the ore mass and its share of the contained iron are different quantities. A mineralogical report should make the basis clear.<\/p>\n<\/section><section class=\"ore-section\" id=\"measure-tailings\"><h2>What should you measure in the magnetite tailings?<\/h2>\n<p><strong>Measure how much iron leaves, which minerals carry it and whether those minerals are free from gangue.<\/strong> Gangue means the unwanted minerals, such as quartz. Total Fe alone tells you the amount of iron, but not which separation step can recover it.<\/p>\n<h3>Collect matching stream samples<\/h3>\n<p>For a running plant, collect feed, magnetic concentrate and tailings over the same stable operating period. Allow for the travel time between sampling points. Take increments across the stream and over time, then combine them for each stream; a scoop from the settled surface can favor a particular size or density.<\/p>\n<p>Record dry-solids mass or flow, slurry flow, solids concentration, particle-size distribution, ore blend and the separator settings. State whether solids concentration is measured by mass or volume. Weigh wet samples and determine moisture so that the balance uses <strong>dry tonnes throughout<\/strong>.<\/p>\n<p>Assay total Fe and the impurities relevant to your product, including silica, alumina, phosphorus or sulfur where applicable. Separate useful size fractions and weigh and assay each one. This shows whether a high-grade fine fraction contains enough iron mass to matter, or whether most of the loss sits elsewhere.<\/p>\n<h3>Find the iron mineral and its liberation<\/h3>\n<p>Ask for mineral identification and images of the iron-bearing particles in the important loss fractions. X-ray diffraction identifies mineral phases. Polished-section microscopy and automated mineral mapping, such as MLA or QEMSCAN, show which minerals occur together and how much iron remains locked in composite particles. Chemical phase analysis or M\u00f6ssbauer spectroscopy can help resolve the iron phases when the initial mineral identification is unclear.<\/p>\n<p><strong>Particle size is not the same as mineral grain size.<\/strong> A small particle can still contain a very fine hematite\u2013quartz intergrowth. Grinding the whole feed finer helps only if it creates enough useful liberation to justify the extra grinding and fine-particle treatment.<\/p>\n<div aria-label=\"Tailings findings and next investigations\" class=\"ore-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th scope=\"col\">What the tailings show<\/th>\n<th scope=\"col\">What to investigate next<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Liberated magnetite remains in a size fraction the drum should handle<\/td>\n<td>Compare feed distribution, slurry flow, solids load and magnetic loading with the stable baseline. Repeat a controlled LIMS test before adding a hematite circuit.<\/td>\n<\/tr>\n<tr>\n<td>Liberated hematite carries an important share of the remaining iron<\/td>\n<td>Compare wet high-intensity or high-gradient magnetic separation with a gravity test where the particle size and density contrast suit it.<\/td>\n<\/tr>\n<tr>\n<td>Hematite or magnetite remains locked with quartz<\/td>\n<td>Regrind a selected composite-rich stream, then repeat separation and measure whether grade and iron recovery improve together.<\/td>\n<\/tr>\n<tr>\n<td>Much of the iron is in very fine particles<\/td>\n<td>Measure the fine fraction&#8217;s mass, Fe and liberation; compare ways of treating it before choosing a desliming cut.<\/td>\n<\/tr>\n<tr>\n<td>Iron occurs in silicates, carbonates or other phases<\/td>\n<td>Recalculate the recoverable target by mineral. A hematite recovery step may address only part of that iron.<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>Keep the original sample IDs, weights, size fractions and assay sheets together. An independent laboratory can then repeat the assays or examine the same mineral fractions, rather than trying to explain a result from a final Fe number alone.<\/p>\n<\/section><section class=\"ore-section\" id=\"compare-recovery-paths\"><h2>Which recovery paths should you compare?<\/h2>\n<p><strong>Use the existing magnetite stage as the baseline, then test the remaining iron in a separate branch.<\/strong> Choose the branch from the mineral and liberation results. Keep its product separate until you know whether it can meet the required quality by itself or after cleaning.<\/p>\n<h3>Recover magnetite before the weakly magnetic fraction<\/h3>\n<p>A useful first comparison for ground mixed ore is LIMS for magnetite, followed by high-intensity treatment of the LIMS tailings. Wet high-intensity magnetic separation, or WHIMS, applies a stronger magnetic field. High-gradient magnetic separation, or HGMS, also uses a steep change in field strength near the capture surfaces. Some machines combine both features.<\/p>\n<p>The stronger field and gradient help attract weakly magnetic hematite. Capture also depends on the particle&#8217;s size and magnetic response, and on the slurry forces trying to carry it away. That is why two machines with a similar nominal field can give different results.<\/p>\n<p>For the comparison, divide a well-mixed tailings sample into representative test portions. Establish a baseline at the current size, then vary the magnetic setting, feed solids and flow within the test machine&#8217;s operating range. For a matrix-type machine, record the matrix and its cleaning conditions; for a plate-type machine, record the plate arrangement, feed spread and belt settings. Use the settings that actually exist on that design.<\/p>\n<p>Collect and weigh every concentrate, reject and cleaning stream. A setting that pulls more solids is useful only if the additional material contains enough recoverable iron and can be upgraded to the required product.<\/p>\n<h3>Compare regrinding, gravity and flotation only where they help<\/h3>\n<p>If the magnetic product contains iron-rich particles still attached to quartz, compare <strong>selective regrinding of that product<\/strong> with further grinding of the full feed. Rejecting waste before regrinding can reduce the mass entering the mill. But the circuit must still account for iron lost in that early reject.<\/p>\n<p>Where hematite is already liberated and the size range suits density separation, compare gravity concentration on the same feed. A gravity result from coarse, free hematite does not establish what will happen to a fine intergrown fraction. Measure each test&#8217;s dry yield, Fe, impurities and iron recovery on the same basis.<\/p>\n<p>When magnetic concentration recovers iron but leaves too much quartz, flotation can be the next upgrading test. In reverse flotation, the aim is to float the unwanted gangue while retaining the iron-rich product. Use mineral and water analysis to develop the reagent tests; a published reagent recipe belongs to the ore and water used in that study.<\/p>\n<h3>Keep fine-particle losses in the balance<\/h3>\n<p>Desliming removes a selected fine fraction before the next process. It can improve feed handling or selectivity, but it also removes any iron in that fraction. <strong>Compare the complete feed with a classified-feed option before discarding iron-rich fines.<\/strong> Include both the removed fines and the downstream rejects when calculating total iron recovery.<\/p>\n<p>A <a href=\"https:\/\/scielo.org.za\/scielo.php?pid=S2225-62532014000700013&amp;script=sci_arttext\" rel=\"nofollow noopener\" target=\"_blank\">published fine-hematite WHIMS investigation<\/a> found that treating its full size distribution improved fine-particle recovery compared with treating the fine fraction alone. It also examined how magnetic capture competes with slurry drag. Use those findings to plan a comparison; the best split size still comes from your material and the intended separator.<\/p>\n<\/section><section class=\"ore-section\" id=\"mixed-ore-study\"><h2>What does the published mixed-ore study actually show?<\/h2>\n<p><strong>The study shows that magnetic recovery and final upgrading must be judged together: higher final Fe grade came with lower iron recovery to that final concentrate.<\/strong> Nikolaeva and co-authors studied difficult magnetite\u2013hematite ore from Russia&#8217;s Mikhailovskoye deposit, using mineralogical analysis and laboratory magnetic and flotation tests.<\/p>\n<p>The <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC8028150\/#tbl7\" rel=\"nofollow noopener\" target=\"_blank\">open-access paper&#8217;s Tables 7\u20139<\/a> report these results:<\/p>\n<div aria-label=\"Published mixed-ore concentrate results\" class=\"ore-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th scope=\"col\">Reported concentrate<\/th>\n<th scope=\"col\">Fe grade<\/th>\n<th scope=\"col\">SiO\u2082 grade<\/th>\n<th scope=\"col\">Total Fe recovery<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Initial magnetic beneficiation<\/td>\n<td>52.9%<\/td>\n<td>23.8%<\/td>\n<td>85.5%<\/td>\n<\/tr>\n<tr>\n<td>Two-stage magnetic beneficiation with regrinding<\/td>\n<td>58.50%<\/td>\n<td>15.70%<\/td>\n<td>75.02%<\/td>\n<\/tr>\n<tr>\n<td>Final magnetic\u2013flotation concentrate<\/td>\n<td>69.20%<\/td>\n<td>1.98%<\/td>\n<td>53.35%<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>Table 9 also reports a middlings stream carrying 10.94% of the feed iron. Middlings are an intermediate product requiring further treatment. Counting them as final concentrate would overstate the iron recovered to the finished product.<\/p>\n<p>The laboratory equipment included an SLON-100 high-gradient separator. Its operating conditions belong to that test system. A plate-type wet separator has a different capture and discharge arrangement, so equipment selection needs a material test on the proposed design.<\/p>\n<p>For your plant, compare the same outputs at every step: <strong>final product quality, dry product tonnes and iron recovered from the original feed<\/strong>. A high recovery into a rough concentrate is a useful first result; its value depends on what remains after cleaning, impurity removal and dewatering.<\/p>\n<\/section><section class=\"ore-section\" id=\"calculate-final-iron\"><h2>How much extra iron reaches a usable final product?<\/h2>\n<p><strong>Calculate the iron mass in each final product, then divide by the iron mass in the original feed.<\/strong> Separately calculate the added stage&#8217;s recovery from its own feed. Keep those two denominators visible.<\/p>\n<p>Use these relationships, with assays expressed as mass fractions:<\/p>\n<ul>\n<li>Iron in a stream = dry stream mass \u00d7 Fe fraction.<\/li>\n<li>Overall Fe recovery = iron in accepted final products \u00f7 iron in original feed \u00d7 100%.<\/li>\n<li>Blended Fe grade = total iron in the blended products \u00f7 their total dry mass \u00d7 100%.<\/li>\n<\/ul>\n<p>Consider a worked example with <strong>100 dry tonnes of ore at 35% Fe<\/strong>, containing 35 tonnes of iron. The magnetite circuit produces 35 dry tonnes of concentrate at 65% Fe. Its concentrate contains 22.75 tonnes of iron, giving <strong>65% overall Fe recovery<\/strong>. The remaining 65 tonnes contain 12.25 tonnes of iron.<\/p>\n<p>Suppose an added hematite recovery test produces these three outlet streams before any extra concentrate cleaning:<\/p>\n<div aria-label=\"Worked example dry mass and iron balance\" class=\"ore-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th scope=\"col\">Stream<\/th>\n<th scope=\"col\">Dry mass<\/th>\n<th scope=\"col\">Fe grade<\/th>\n<th scope=\"col\">Contained iron<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Existing magnetite concentrate<\/td>\n<td>35 t<\/td>\n<td>65.00%<\/td>\n<td>22.75 t<\/td>\n<\/tr>\n<tr>\n<td>Added branch concentrate<\/td>\n<td>10 t<\/td>\n<td>50.00%<\/td>\n<td>5.00 t<\/td>\n<\/tr>\n<tr>\n<td>Remaining tailings<\/td>\n<td>55 t<\/td>\n<td>13.18% rounded<\/td>\n<td>7.25 t<\/td>\n<\/tr>\n<tr>\n<td>Total<\/td>\n<td>100 t<\/td>\n<td>\u2014<\/td>\n<td>35.00 t<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>The added stage recovers <strong>5 \u00f7 12.25 \u00d7 100 = 40.82%<\/strong> of the iron entering that branch. Combined iron recovery becomes <strong>(22.75 + 5) \u00f7 35 \u00d7 100 = 79.29%<\/strong>, an increase of 14.29 percentage points from the original ore.<\/p>\n<p>But mixing both concentrates gives <strong>27.75 \u00f7 45 \u00d7 100 = 61.67% Fe<\/strong>. If the example buyer requires at least 63% Fe, that blend fails the Fe requirement even though iron recovery has risen. Keep the branch concentrate separate and test cleaning or a different product outlet.<\/p>\n<p>Now suppose cleaning turns the 10-tonne branch concentrate into <strong>7 tonnes at 62% Fe<\/strong>. It retains 4.34 tonnes of iron and loses 0.66 tonnes to the cleaning reject. The new blend contains 35 + 7 = 42 tonnes of solids and 22.75 + 4.34 = 27.09 tonnes of iron:<\/p>\n<ul>\n<li>Blended grade = 27.09 \u00f7 42 \u00d7 100 = <strong>64.50% Fe<\/strong>.<\/li>\n<li>Overall recovery = 27.09 \u00f7 35 \u00d7 100 = <strong>77.40%<\/strong>.<\/li>\n<li>Recovery gain over the original circuit = 77.40 \u2212 65.00 = <strong>12.40 percentage points<\/strong>.<\/li>\n<\/ul>\n<p>This cleaned blend meets the example&#8217;s Fe minimum, while the uncleaned blend does not. Silica, alumina, phosphorus, sulfur, moisture and size requirements still need their own product results. The 63% minimum here is an assumed buyer requirement, not a universal iron concentrate specification.<\/p>\n<p>For a real trial, total every final outlet on the same dry basis, including slime discard, cleaner rejects and any unrecovered middlings. Compare both solids and contained-iron totals with the feed. If the balance does not close within the trial&#8217;s agreed sampling and analytical uncertainty, resolve the weights, moisture or assays before using the result to size the added circuit.<\/p>\n<\/section><section class=\"ore-section\" id=\"assess-added-circuit\"><h2>When is an added hematite circuit worth taking further?<\/h2>\n<p><strong>Take it further when repeatable tests recover additional iron into an acceptable final product at a useful throughput and a workable total cost.<\/strong> Keep the present circuit when the remaining iron is too difficult to liberate, the added product cannot be upgraded economically or the extra treatment reduces the value of the existing concentrate.<\/p>\n<p>Start with repeat bench tests on the ore blends that change the result, rather than only the highest-grade sample. Compare iron recovery and impurity rejection at the same feed basis. If a blend has more hematite, finer intergrowths or more clay, include it in the test set instead of averaging away the difficult condition.<\/p>\n<p>Before ordering a full-scale branch, use continuous or pilot testing to examine the conditions a small batch test leaves out: variable feed, solids and slurry loading, capture-surface cleaning, wear, recycled water and circulating middlings. Include the full cleaning sequence. A recirculating middlings stream can build up a load that a single pass never shows.<\/p>\n<p>Size the branch for <strong>dry solids and slurry flow<\/strong>. Its feed is the selected residual stream, which can be a large share of the original ore mass. Diluting the slurry may improve a separation test while increasing pump, thickener and water-handling requirements. Record the water addition with the result so the plant design includes that load.<\/p>\n<p>Compare the value of additional accepted product with the added grinding, pumping, magnetic separation, flotation if needed, wear parts, labor, water treatment and dewatering. Include installation, tie-ins and the cost of interrupting the existing line. Use current project quotations and your actual product terms to calculate the return; a recovery percentage alone does not give a payback period.<\/p>\n<p>For a retrofit, preserve a way to run the original magnetite circuit while the new branch is isolated. Keep the two concentrates separately sampled and routed until blending trials satisfy the required Fe and impurity limits. This protects the existing product while the added branch is being commissioned.<\/p>\n<p>The most useful outcome of mixed magnetite\u2013hematite ore beneficiation is <strong>more iron in a product you can use or sell<\/strong>. Recover magnetite efficiently, identify what remains, and add hematite treatment only where the final-product balance supports it.<\/p>\n<\/section><section class=\"ore-section\" id=\"equipment-selection\"><h2>What should you send us for equipment selection?<\/h2>\n<p><strong>Send the residual stream&#8217;s mineralogy, size distribution, dry-solids rate, slurry flow and required product result, together with the existing flowsheet.<\/strong> These inputs let us discuss the separator that fits the actual stream instead of selecting from total Fe or a nominal field number.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/wet-drum-magnetic-separator\/\">CTS(N.B.) wet drum magnetic separators<\/a> are intended for strongly magnetic material in slurry, including magnetite recovery and cleaning. If the residual iron is still liberated magnetite, start by reviewing that duty and its loading.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/wet-high-intensity-magnetic-separator\/\">plate-type wet high-intensity magnetic separator<\/a> addresses weakly magnetic targets in wet feed that can spread evenly across the plate. For a hematite branch, compare its feed presentation and test results with the required recovery and grade. A vertical-ring matrix separator is a different design; specify the tested capture arrangement when discussing the equipment.<\/p>\n<p>For an existing plant, add matching feed, concentrate and tailings assays, the current settings and the size fractions carrying most of the lost iron. For a new project, send the available ore characterization and the intended product specification. Include silica, phosphorus or other limits that could determine whether the recovered product can be blended.<\/p>\n<p>Use our <a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">contact form<\/a> to describe the stream and the change you are considering. Send assay reports and flowsheet files by email to <a href=\"mailto:sales@corvelanmag.com\">sales@corvelanmag.com<\/a>. Keep the sample IDs and test conditions with the results so the equipment discussion uses the same material basis.<\/p>\n<\/section><section class=\"ore-section ore-faq faq\" id=\"mixed-ore-faq\"><h2>Mixed magnetite\u2013hematite ore FAQ<\/h2>\n<h3>Our magnetite concentrate meets the specification. Should we still recover hematite from the tailings?<\/h3>\n<p><strong>Only if the residual iron can produce additional acceptable product at a worthwhile cost.<\/strong> A high tailings Fe assay is a reason to investigate, rather than a reason by itself to add equipment. Establish the iron-bearing minerals and the mass of iron available, then compare the finished branch product and its treatment cost. Keeping an existing stable circuit can be the better choice when the remaining iron is finely locked or costly to upgrade.<\/p>\n<h3>A hand magnet attracts both dark and red particles. Does that prove LIMS can recover hematite?<\/h3>\n<p><strong>No. A magnetic fraction can contain hematite attached to magnetite or physically carried with other particles.<\/strong> Color and hand-magnet attraction do not establish the recovery of liberated hematite. Examine the particle associations and assay the magnetic and non-magnetic products of a controlled separation test. That distinguishes a mixed captured particle from a separately liberated weakly magnetic mineral.<\/p>\n<h3>Can we use a fresh-ore test to select equipment for old magnetite tailings?<\/h3>\n<p><strong>Use representative samples from the tailings you intend to reclaim.<\/strong> Their ore history, size distribution and mineral condition may differ from the present plant feed. Keep samples from different storage zones or depths separate until you know how they differ. Plan any tailings-storage sampling with the site&#8217;s responsible team, then test a reclaim blend based on the actual mining or reclaim plan. The resulting slurry condition must also suit the proposed feed system.<\/p>\n<h3>If the added stage recovers 60% of its feed iron, does plant recovery rise by 60 percentage points?<\/h3>\n<p><strong>No. Multiply that recovery by the share of original feed iron entering the added stage.<\/strong> If 20% of the original iron reaches the branch, and the branch recovers 60% of it into accepted final product, the gain is 20% \u00d7 60% = 12 percentage points. If 60% describes a rough concentrate before cleaning, first account for iron lost in the later cleaning steps.<\/p>\n<h3>What can we do first if there is no budget for another separator?<\/h3>\n<p><strong>Locate the main iron loss before reserving capital for a new circuit.<\/strong> Use the current stream samples, size-by-assay results and mineral examination to separate magnetite losses from the hematite opportunity. Correct an identified feed-distribution or loading problem in the existing circuit, then measure the result again. If hematite recovery remains promising, use a small representative test program to define the branch and reserve sampling points, routing space and a bypass in the future layout.<\/p><\/section><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Our magnetite concentrate meets the specification. Should we still recover hematite from the tailings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only if the residual iron can produce additional acceptable product at a worthwhile cost. A high tailings Fe assay is a reason to investigate, rather than a reason by itself to add equipment. Establish the iron-bearing minerals and the mass of iron available, then compare the finished branch product and its treatment cost. Keeping an existing stable circuit can be the better choice when the remaining iron is finely locked or costly to upgrade.\"}}, {\"@type\": \"Question\", \"name\": \"A hand magnet attracts both dark and red particles. Does that prove LIMS can recover hematite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. A magnetic fraction can contain hematite attached to magnetite or physically carried with other particles. Color and hand-magnet attraction do not establish the recovery of liberated hematite. Examine the particle associations and assay the magnetic and non-magnetic products of a controlled separation test. That distinguishes a mixed captured particle from a separately liberated weakly magnetic mineral.\"}}, {\"@type\": \"Question\", \"name\": \"Can we use a fresh-ore test to select equipment for old magnetite tailings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Use representative samples from the tailings you intend to reclaim. Their ore history, size distribution and mineral condition may differ from the present plant feed. Keep samples from different storage zones or depths separate until you know how they differ. Plan any tailings-storage sampling with the site's responsible team, then test a reclaim blend based on the actual mining or reclaim plan. The resulting slurry condition must also suit the proposed feed system.\"}}, {\"@type\": \"Question\", \"name\": \"If the added stage recovers 60% of its feed iron, does plant recovery rise by 60 percentage points?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Multiply that recovery by the share of original feed iron entering the added stage. If 20% of the original iron reaches the branch, and the branch recovers 60% of it into accepted final product, the gain is 20% \u00d7 60% = 12 percentage points. If 60% describes a rough concentrate before cleaning, first account for iron lost in the later cleaning steps.\"}}, {\"@type\": \"Question\", \"name\": \"What can we do first if there is no budget for another separator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Locate the main iron loss before reserving capital for a new circuit. Use the current stream samples, size-by-assay results and mineral examination to separate magnetite losses from the hematite opportunity. Correct an identified feed-distribution or loading problem in the existing circuit, then measure the result again. If hematite recovery remains promising, use a small representative test program to define the branch and reserve sampling points, routing space and a bypass in the future layout.\"}}]}<\/script><\/article>\n","protected":false},"excerpt":{"rendered":"<p>Quick Summary Mixed magnetite hematite ore beneficiation starts by finding which iron minerals remain after magnetite recovery. Keep low-intensity magnetic separation for liberated magnetite. Test a separate recovery step for liberated hematite, and use targeted regrinding when valuable iron is still locked with waste minerals. Choose the added step by the iron that reaches an [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5584","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5584","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/comments?post=5584"}],"version-history":[{"count":1,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5584\/revisions"}],"predecessor-version":[{"id":5621,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/posts\/5584\/revisions\/5621"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media\/4477"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media?parent=5584"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/categories?post=5584"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/tags?post=5584"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}