{"id":4554,"date":"2026-06-25T09:06:35","date_gmt":"2026-06-25T01:06:35","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?post_type=product&#038;p=4554"},"modified":"2026-09-27T18:24:42","modified_gmt":"2026-09-27T10:24:42","slug":"air-cooled-electromagnetic-separator","status":"publish","type":"product","link":"https:\/\/www.corvelanmag.com\/es\/products\/air-cooled-electromagnetic-separator\/","title":{"rendered":"Separador electromagn\u00e9tico refrigerado por aire"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4554\" class=\"elementor elementor-4554\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-582c2aa e-con e-atomic-element e-div-block-base e-default-div e-582c2aa-a856798 \" data-id=\"582c2aa\" data-element_type=\"e-div-block\" data-e-type=\"e-div-block\" data-interaction-id=\"582c2aa\" data-e-type=\"e-div-block\" data-id=\"582c2aa\">\n    \t\t<div class=\"elementor-element elementor-element-bf8b2a8 elementor-widget elementor-widget-html\" data-id=\"bf8b2a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<style>\r\n.coverlan-pdp{--cl-navy:#0b2f4d;--cl-blue:#165c8d;--cl-blue2:#eaf3f8;--cl-ink:#172736;--cl-muted:#5d6c78;--cl-line:#d8e2e9;--cl-soft:#f4f7f9;--cl-warn:#fff7e8;--cl-white:#fff;font-family:Arial,Helvetica,sans-serif;color:var(--cl-ink);line-height:1.64;width:100%;overflow-x:clip;background:#fff}\r\n.coverlan-pdp *{box-sizing:border-box}.coverlan-pdp .cl-section{width:100%;margin:0;background:#fff}.coverlan-pdp .cl-soft{background:var(--cl-soft)}.coverlan-pdp .cl-dark{background:var(--cl-navy);color:#fff}.coverlan-pdp .cl-inner{width:100%;max-width:1400px;margin:0 auto;padding:72px 0;box-sizing:border-box}.coverlan-pdp .cl-hero .cl-inner{padding-top:56px;padding-bottom:56px}.coverlan-pdp .cl-hero-grid{display:grid;grid-template-columns:minmax(0,1.04fr) minmax(380px,.96fr);gap:52px;align-items:center}.coverlan-pdp h1,.coverlan-pdp h2,.coverlan-pdp h3{line-height:1.18;margin:0 0 17px;color:var(--cl-navy)}.coverlan-pdp h1{font-size:36px;letter-spacing:-.02em}.coverlan-pdp h2{font-size:28px;letter-spacing:-.012em}.coverlan-pdp h3{font-size:20px}.coverlan-pdp .cl-dark h2,.coverlan-pdp .cl-dark h3{color:#fff}.coverlan-pdp p{margin:0 0 16px}.coverlan-pdp ul{margin:0;padding-left:21px}.coverlan-pdp li{margin:7px 0}.coverlan-pdp .cl-eyebrow{font-size:13px;font-weight:700;text-transform:uppercase;letter-spacing:.09em;color:var(--cl-blue);margin-bottom:10px}.coverlan-pdp .cl-lead{font-size:19px;color:#344a5c;max-width:850px}.coverlan-pdp .cl-dark .cl-lead{color:#dfeaf2}.coverlan-pdp .cl-actions{display:flex;gap:12px;flex-wrap:wrap;margin-top:25px}.coverlan-pdp .cl-btn{display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:11px 19px;border-radius:6px;text-decoration:none;font-weight:700;border:1px solid var(--cl-blue)}.coverlan-pdp .cl-btn-primary{background:var(--cl-blue);color:#fff}.coverlan-pdp .cl-btn-secondary{background:#fff;color:var(--cl-blue)}.coverlan-pdp .cl-dark .cl-btn-primary{background:#fff;color:var(--cl-navy);border-color:#fff}.coverlan-pdp .cl-media{background:#fff;border:1px solid var(--cl-line);border-radius:10px;padding:10px}.coverlan-pdp .cl-media img{display:block;width:100%;height:auto;border-radius:6px}.coverlan-pdp .cl-caption{font-size:12px;color:var(--cl-muted);margin:8px 0 0}.coverlan-pdp .cl-grid-2{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:28px}.coverlan-pdp .cl-grid-3{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:20px}.coverlan-pdp .cl-grid-4{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:18px}.coverlan-pdp .cl-snapshot{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px;margin:25px 0 0}.coverlan-pdp .cl-snap{border-left:3px solid var(--cl-blue);background:#fff;padding:11px 13px}.coverlan-pdp .cl-snap strong{display:block;font-size:12px;text-transform:uppercase;letter-spacing:.05em;color:var(--cl-muted);margin-bottom:3px}.coverlan-pdp .cl-card{border:1px solid var(--cl-line);background:#fff;border-radius:8px;padding:22px}.coverlan-pdp .cl-card h3{margin-top:0}.coverlan-pdp .cl-note{border-left:4px solid var(--cl-blue);background:var(--cl-blue2);padding:18px 20px;margin:24px 0}.coverlan-pdp .cl-warn{border-left-color:#d08b27;background:var(--cl-warn)}.coverlan-pdp .cl-table-wrap{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;border:1px solid var(--cl-line);border-radius:8px;background:#fff}.coverlan-pdp table{border-collapse:collapse;width:100%;min-width:780px}.coverlan-pdp th,.coverlan-pdp td{padding:13px 14px;text-align:left;vertical-align:top;border-bottom:1px solid var(--cl-line)}.coverlan-pdp th{background:#edf4f8;color:var(--cl-navy);font-size:14px}.coverlan-pdp .cl-pill{display:inline-block;padding:4px 8px;border-radius:999px;background:var(--cl-blue2);color:var(--cl-blue);font-size:12px;font-weight:700}.coverlan-pdp .cl-faq{border-top:1px solid var(--cl-line);padding:15px 0}.coverlan-pdp .cl-faq:last-child{border-bottom:1px solid var(--cl-line)}.coverlan-pdp .cl-faq summary{cursor:pointer;font-weight:700;color:var(--cl-navy)}.coverlan-pdp .cl-faq p{margin:10px 0 0}.coverlan-pdp .cl-rfq{display:grid;grid-template-columns:1fr 1fr;gap:28px}.coverlan-pdp .cl-list-clean{list-style:none;padding:0}.coverlan-pdp .cl-list-clean li{padding:9px 0;border-bottom:1px solid var(--cl-line)}.coverlan-pdp .cl-steps{counter-reset:clstep;display:grid;grid-template-columns:repeat(5,minmax(0,1fr));gap:14px}.coverlan-pdp .cl-step{border:1px solid var(--cl-line);border-radius:8px;padding:18px;background:#fff}.coverlan-pdp .cl-step:before{counter-increment:clstep;content:counter(clstep);display:inline-flex;width:30px;height:30px;align-items:center;justify-content:center;border-radius:50%;background:var(--cl-navy);color:#fff;font-weight:700;margin-bottom:12px}.coverlan-pdp a:focus{outline:3px solid #8dc8ee;outline-offset:3px}.coverlan-pdp .cl-anchor{scroll-margin-top:20px}\r\n@media(max-width:1024px){.coverlan-pdp .cl-inner{padding-left:24px;padding-right:24px}.coverlan-pdp .cl-hero-grid{grid-template-columns:1fr;gap:30px}.coverlan-pdp .cl-grid-4,.coverlan-pdp .cl-steps{grid-template-columns:repeat(2,minmax(0,1fr))}.coverlan-pdp .cl-grid-3{grid-template-columns:repeat(2,minmax(0,1fr))}}\r\n@media(max-width:767px){.coverlan-pdp .cl-inner{padding:54px 16px}.coverlan-pdp .cl-hero .cl-inner{padding-top:42px;padding-bottom:46px}.coverlan-pdp h1{font-size:30px}.coverlan-pdp h2{font-size:24px}.coverlan-pdp .cl-lead{font-size:17px}.coverlan-pdp .cl-grid-2,.coverlan-pdp .cl-grid-3,.coverlan-pdp .cl-grid-4,.coverlan-pdp .cl-snapshot,.coverlan-pdp .cl-rfq,.coverlan-pdp .cl-steps{grid-template-columns:1fr}.coverlan-pdp .cl-btn{width:100%}.coverlan-pdp .cl-media{padding:7px}}\r\n\r\n.coverlan-pdp .cl-note a{color:var(--cl-blue);font-weight:700;text-decoration:none}.coverlan-pdp .cl-note a:hover{text-decoration:underline}.coverlan-pdp .cl-dark .cl-note a{color:#fff}\r\n\r\n\r\n.coverlan-pdp .cl-evidence-grid{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:18px;margin-top:22px}\r\n.coverlan-pdp .cl-evidence-card{border:1px solid var(--cl-line);background:#fff;border-radius:8px;padding:20px}\r\n.coverlan-pdp .cl-evidence-card h3{margin-top:0}\r\n.coverlan-pdp .cl-evidence-card p:last-child{margin-bottom:0}\r\n.coverlan-pdp .cl-kicker{font-size:12px;font-weight:700;text-transform:uppercase;letter-spacing:.05em;color:var(--cl-blue);margin-bottom:7px}\r\n@media(max-width:1024px){.coverlan-pdp .cl-evidence-grid{grid-template-columns:repeat(2,minmax(0,1fr))}}\r\n@media(max-width:767px){.coverlan-pdp .cl-evidence-grid{grid-template-columns:1fr}}\r\n<\/style>\r\n<div class=\"coverlan-pdp\">\r\n<section class=\"cl-section cl-hero\"><div class=\"cl-inner\"><div class=\"cl-hero-grid\"><div>\r\n<h1>Air-Cooled Suspended Electromagnetic Separator<\/h1>\r\n<div class=\"cl-eyebrow\">Conveyor Tramp-Iron Removal<\/div>\r\n<p class=\"cl-lead\">Corvelan air-cooled electromagnetic separators remove unwanted iron and steel from material moving on a conveyor. The electromagnet uses forced air to carry heat away while it runs. We choose the setup from your belt width, working distance, material depth, belt speed and target tramp iron.<\/p>\r\n<div class=\"cl-snapshot\"><div class=\"cl-snap\"><strong>Best For<\/strong>Conveyor-fed bulk material with unwanted ferrous tramp metal.<\/div><div class=\"cl-snap\"><strong>Target<\/strong>Iron and steel pieces that respond to the magnetic field.<\/div><div class=\"cl-snap\"><strong>Typical Installation<\/strong>Suspended above a belt conveyor or transfer point after layout review.<\/div><div class=\"cl-snap\"><strong>Start With<\/strong>Belt width, working distance, burden depth, belt speed and target tramp iron.<\/div><\/div>\r\n<div class=\"cl-actions\"><a class=\"cl-btn cl-btn-primary\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Ask Corvelan to Size It<\/a><a class=\"cl-btn cl-btn-secondary\" href=\"#selection\">See How We Size It<\/a><\/div>\r\n<\/div><div class=\"cl-media\"><img decoding=\"async\" alt=\"Representative air-cooled suspended electromagnetic separator with forced-air cooling fan\" loading=\"eager\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-hero-202609202301-a7f3c2.webp\"><\/div><\/div>\r\n<div class=\"cl-note\"><strong>Built Around Your Conveyor System:<\/strong> We do not choose this equipment from one surface-Gauss number or one catalog size. We check where the iron sits in the material, how the conveyor runs, how the iron will be removed and the site conditions. We then confirm the final setup in the quotation and general arrangement (GA) drawing.<\/div>\r\n<\/div><\/section>\r\n<section class=\"cl-section cl-soft\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Is It a Good Fit?<\/div><h2>Is an air-cooled electromagnetic separator a good fit for your process?<\/h2><p>This separator is a good option for dry or reasonably free-moving material on a conveyor. It removes unwanted iron and steel tramp metal. We also check how far the iron is from the magnet and how often cleaning is needed. The conveyor layout and site power conditions also matter.<\/p><div class=\"cl-grid-2\"><div class=\"cl-card\"><h3>Good fit when<\/h3><ul><li>Iron or steel tramp metal is the main contamination problem.<\/li><li>The material moves on a conveyor or through a transfer point.<\/li><li>There is space to suspend and support the separator.<\/li><li>Belt width, belt speed and burden depth can be defined.<\/li><li>The captured iron has a practical discharge or cleaning method.<\/li><\/ul><\/div><div class=\"cl-card\"><h3>Use another method when<\/h3><ul><li>The main target is aluminum or copper.<\/li><li>The process is a wet slurry or pressure pipeline.<\/li><li>The main job is separating fine, weakly magnetic minerals rather than removing tramp iron.<\/li><li>The required working distance or conveyor layout is not practical for a suspended separator.<\/li><li>The site has special hazardous-area or compliance needs that have not yet been defined.<\/li><\/ul><\/div><\/div><\/div><\/section>\r\n<section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Material &amp; Tramp Iron<\/div><h2>What material and tramp iron can this separator handle?<\/h2><p>Corvelan uses this equipment to remove unwanted iron and steel from conveyor-fed bulk materials. Common tramp metal includes bolts, nuts, tools, chain pieces and scrap steel. The result depends on the size, shape, weight and position of the metal, plus the distance from the magnet.<\/p><p>We can review aggregate, ore, coal, clinker-related material, recycling feed, wood, biomass and other bulk solids. Send us the actual material and target metal so we can check the application.<\/p><p>Aluminum and copper need a non-ferrous separation method. Stainless steel can respond differently by grade and condition. If stainless steel is part of the target, send the grade or a sample requirement.<\/p><\/div><\/section>\r\n<section class=\"cl-section cl-soft\"><div class=\"cl-inner\"><div class=\"cl-grid-2\"><div><div class=\"cl-eyebrow\">Working Principle<\/div><h2>How does an air-cooled electromagnetic separator work?<\/h2><p>When the coil is energized, it creates a magnetic field. Iron and steel pieces are pulled toward the magnet when they enter this field. The farther the iron is from the magnetic face, the harder it is to capture. Material depth, belt speed, and the size and shape of the iron also matter.<\/p><p>The coil creates heat while the magnet is energized. Fans move air around the electromagnetic assembly to carry this heat away. We choose the cooling setup from the required running time, site temperature and magnetic load. The final fan layout is confirmed with the selected separator.<\/p><p>The captured iron still has to be removed. Periodic cleaning can work when tramp loading is low and planned stops are acceptable. Choose a self-cleaning electromagnetic separator when the line needs automatic, continuous iron discharge.<\/p><\/div><div class=\"cl-media\"><img decoding=\"async\" alt=\"Engineering diagram showing an air-cooled electromagnet lifting ferrous pieces from conveyor-fed material\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-working-principle.webp\"><\/div><\/div><\/div><\/section>\r\n<section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-grid-2\"><div class=\"cl-media\"><img decoding=\"async\" alt=\"Top-view representative air-cooled electromagnetic separator showing enclosure, fan position and lifting points\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-cooling-202609202301-b4d8e1.webp\"><\/div><div><div class=\"cl-eyebrow\">Air-Cooled Construction<\/div><h2>What should the air-cooled design provide?<\/h2><p>The fan, coil enclosure, lifting points and service space must work together. We check the required running time, site temperature and available space before we choose the cooling setup.<\/p><ul><li><strong>Cooling access:<\/strong> keep the air path clear and leave enough room to reach the fan.<\/li><li><strong>Lifting and support:<\/strong> use the selected general arrangement (GA) drawing to confirm weight, lifting points and support loads.<\/li><li><strong>Electrical package:<\/strong> match the magnet, fan and controls to the quoted design and site power supply.<\/li><li><strong>Maintenance space:<\/strong> leave room for inspection, cleaning and service without blocking the conveyor or iron discharge area.<\/li><\/ul><\/div><\/div><\/div><\/section>\r\n<section class=\"cl-section cl-soft cl-anchor\" id=\"selection\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">What Affects Capture<\/div><h2>What affects tramp-iron capture?<\/h2><div class=\"cl-grid-3\"><div class=\"cl-card\"><h3>Real working distance<\/h3><p>Measure from the magnetic face to the iron at the hardest place inside the material bed. This is the real working distance. It matters more than the empty gap above the conveyor.<\/p><\/div><div class=\"cl-card\"><h3>Burden depth<\/h3><p>Burden depth means how deep the material bed is on the conveyor. A deeper or uneven bed makes the magnet work through more material and can hold buried iron in place.<\/p><\/div><div class=\"cl-card\"><h3>Belt speed<\/h3><p>Belt speed changes how long the iron stays in the magnetic field. It also changes the material path at transfer points.<\/p><\/div><div class=\"cl-card\"><h3>Target tramp iron<\/h3><p>The size, shape, weight, position and amount of tramp iron all affect how hard it is to capture.<\/p><\/div><div class=\"cl-card\"><h3>Nearby steelwork<\/h3><p>Steel beams, idlers and chutes near the magnet can affect the magnetic field and the space available for installation.<\/p><\/div><div class=\"cl-card\"><h3>Running time &amp; site temperature<\/h3><p>We check how long the magnet needs to run, how much heat the coil makes and the site temperature.<\/p><\/div><\/div><div class=\"cl-note\"><strong>We do not select by Gauss alone.<\/strong> Gauss is magnetic flux density at a defined point. It is not the same as pull force, working-distance capability, removal efficiency or throughput. The useful question is whether the selected field can act on your target at the real operating distance.<\/div><\/div><\/section>\r\n<section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Choose the Right Magnetic Separator Configuration<\/div><h2>Which setup fits your conveyor?<\/h2><p>We evaluate the magnetic solution, cleaning method and installation position separately. We check each one against your conveyor and target tramp iron.<\/p><div class=\"cl-note\"><strong>Compare Magnetic Separation Options First.<\/strong> Air-cooled, oil-cooled and permanent suspended magnets solve similar conveyor problems in different ways. We check the target tramp iron, real working distance, running time and site conditions before recommending the suitable solution.<\/div><h3>Air-cooled vs oil-cooled vs permanent suspended magnet<\/h3><div class=\"cl-table-wrap\"><table><thead><tr><th>Magnetic Solution<\/th><th>What it means<\/th><th>When we review it<\/th><\/tr><\/thead><tbody>\r\n<tr><td><strong>Air-cooled electromagnetic separator<\/strong><\/td><td>An energized coil creates the magnetic field. Forced air carries heat away from the electromagnetic assembly.<\/td><td>Review it when an electromagnetic solution fits the target and working distance, and the site can provide the required electrical supply and airflow.<\/td><\/tr>\r\n<tr><td><strong>Oil-cooled electromagnetic separator<\/strong><\/td><td>An energized coil creates the magnetic field. An oil cooling circuit carries heat away from the electromagnetic assembly.<\/td><td>Compare it when the running condition, site environment or service needs point to an oil-cooled design.<\/td><\/tr>\r\n<tr><td><strong>Permanent suspended magnet<\/strong><\/td><td>A permanent magnetic circuit creates the field. Electrical power is not used to create the magnetic field.<\/td><td>Compare it when a permanent field can meet the target and working distance, and the process does not need an energized coil.<\/td><\/tr>\r\n<\/tbody><\/table><\/div><h3 style=\"margin-top:28px\">Then choose the cleaning and mounting route<\/h3><div class=\"cl-table-wrap\"><table><thead><tr><th>Your situation<\/th><th>Option to consider<\/th><th>What we check<\/th><\/tr><\/thead><tbody>\r\n<tr><td>Iron appears only occasionally, and planned cleaning stops are acceptable<\/td><td><strong>Air-cooled separator with periodic cleaning<\/strong><\/td><td>We check safe access, how much iron can collect and how often the line can stop.<\/td><\/tr>\r\n<tr><td>Frequent tramp iron or automatic discharge is required<\/td><td><strong>Self-cleaning electromagnetic separator<\/strong><\/td><td>We check the discharge belt, drive, guarding, iron path and service space.<\/td><\/tr>\r\n<tr><td>There is room to discharge iron to the side<\/td><td><strong>Crossbelt layout<\/strong><\/td><td>We check orientation, discharge side, support and clearance.<\/td><\/tr>\r\n<tr><td>The separator is near a head pulley or transfer point<\/td><td><strong>Inline layout<\/strong><\/td><td>We check the material path, working distance, head-pulley layout and iron discharge path.<\/td><\/tr>\r\n<tr><td>You prefer an air-cooled design without an oil cooling circuit<\/td><td><strong>Air-cooled electromagnetic separator<\/strong><\/td><td>We check running time, site temperature, airflow and the electrical package.<\/td><\/tr>\r\n<tr><td>Long running hours, hot conditions or a difficult working distance<\/td><td><strong>Compare electromagnetic cooling options<\/strong><\/td><td>We check magnetic reach and heat load first, then choose the cooling method.<\/td><\/tr>\r\n<\/tbody><\/table><\/div><div class=\"cl-actions\"><a class=\"cl-btn cl-btn-primary\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Send Your Conveyor Layout<\/a><\/div><\/div><\/section>\r\n<section class=\"cl-section cl-soft\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Data We Need<\/div><h2>What information do we need to size it?<\/h2><p>One separator size does not fit every conveyor. Send us your conveyor and material details. We use them to choose the equipment and confirm the final values in the quotation and general arrangement (GA) drawing.<\/p><div class=\"cl-table-wrap\"><table><thead><tr><th>What we need<\/th><th>Why it matters<\/th><th>What we confirm<\/th><\/tr><\/thead><tbody>\r\n<tr><td>Conveyor belt width<\/td><td>Sets the magnetic coverage and the equipment width needed above the conveyor.<\/td><td>Selected equipment width and layout.<\/td><\/tr>\r\n<tr><td>Burden depth \/ real working distance<\/td><td>Shows how far the magnetic field must reach to the hardest target position.<\/td><td>Selected setup checked against the stated distance.<\/td><\/tr>\r\n<tr><td>Belt speed<\/td><td>Changes how long the iron stays in the magnetic field and how the material moves.<\/td><td>Selected setup checked against the belt speed.<\/td><\/tr>\r\n<tr><td>Target tramp iron<\/td><td>Piece size, shape, weight and amount affect how hard the iron is to capture.<\/td><td>Target Tramp Iron listed in the sizing notes.<\/td><\/tr>\r\n<tr><td>Cleaning requirement<\/td><td>Shows whether periodic cleaning or automatic discharge is the better choice.<\/td><td>Cleaning and discharge method in the proposal.<\/td><\/tr>\r\n<tr><td>Electrical supply<\/td><td>The magnet, fan and controls must match the site power supply.<\/td><td>Electrical scope for the selected equipment.<\/td><\/tr>\r\n<tr><td>Ambient \/ dust condition<\/td><td>Dust and site temperature affect cooling and equipment protection.<\/td><td>Equipment checked against the stated site conditions.<\/td><\/tr>\r\n<tr><td>Installation position<\/td><td>Crossbelt and inline layouts need different space and iron discharge paths.<\/td><td>GA drawing for the selected installation.<\/td><\/tr>\r\n<tr><td>Dimensions &amp; weight<\/td><td>Needed for support steel, lifting and service space.<\/td><td>Final values in the quotation and GA drawing.<\/td><\/tr>\r\n<tr><td>Acceptance requirement<\/td><td>If you need a measured result, the target and test method must be defined.<\/td><td>Agreed test or inspection plan when needed.<\/td><\/tr>\r\n<\/tbody><\/table><\/div><\/div><\/section>\r\n<section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Where It Works<\/div><h2>Where can we install air-cooled electromagnetic separators?<\/h2><div class=\"cl-grid-4\"><div class=\"cl-card\"><h3>Before crushers<\/h3><p>Remove iron and steel tramp metal before it reaches the crusher. We check the target metal and working distance first.<\/p><\/div><div class=\"cl-card\"><h3>Before mills<\/h3><p>Remove iron and steel pieces before they reach downstream grinding equipment.<\/p><\/div><div class=\"cl-card\"><h3>At transfer points<\/h3><p>A transfer point can be a good location. It can reduce the working distance and give captured iron a clear discharge path.<\/p><\/div><div class=\"cl-card\"><h3>On bulk conveyors<\/h3><p>We can configure the separator for mining, aggregate, coal, recycling, biomass and other conveyor-fed bulk materials that may contain tramp iron.<\/p><\/div><\/div><div class=\"cl-note\"><strong>Related Applications:<\/strong> <a href=\"https:\/\/www.corvelanmag.com\/applications\/conveyor-magnet\/\">Conveyor Magnet Selection<\/a> \u00b7 <a href=\"https:\/\/www.corvelanmag.com\/applications\/coal-magnetic-separator\/\">Coal Conveyor Iron Removal<\/a> \u00b7 <a href=\"https:\/\/www.corvelanmag.com\/applications\/scrap-metal-separation\/\">Scrap Metal Magnetic Separation<\/a>.<\/div><\/div><\/section>\r\n<section class=\"cl-section cl-soft\"><div class=\"cl-inner\"><div class=\"cl-grid-2\"><div><div class=\"cl-eyebrow\">Installation<\/div><h2>How should the separator be installed above the conveyor?<\/h2><p>Keep the magnetic face as close as practical to the tramp iron. You still need enough space for safe material flow, iron discharge and maintenance. We also check nearby steelwork because it can affect the magnetic field.<\/p><ul><li>Measure from the magnetic face to the hardest target position inside the material.<\/li><li>Record the normal and maximum material depth, not only the empty-belt gap.<\/li><li>Check whether crossbelt or inline installation gives enough room to discharge the captured iron.<\/li><li>Keep unnecessary steel away from the active magnetic area where practical.<\/li><li>Use the selected GA drawing for final support loads, lifting points and service space.<\/li><\/ul><\/div><div class=\"cl-media\"><img decoding=\"async\" alt=\"Diagram showing working distance, burden depth, conveyor motion and service clearance for suspended electromagnet selection\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-installation-variables.webp\"><\/div><\/div><div class=\"cl-grid-2\" style=\"margin-top:28px\"><div class=\"cl-media\"><img decoding=\"async\" alt=\"Representative suspended electromagnetic separator enclosure with alternative mounting bracket arrangement\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-mounting-202609202301-d2e7b5.webp\"><\/div><div class=\"cl-card\"><h3>Send a layout before you build the support frame<\/h3><p>Send us a conveyor side view, belt width, material depth and available headroom. We can then check the magnet position, iron discharge direction and service space before the support frame is built.<\/p><div class=\"cl-actions\"><a class=\"cl-btn cl-btn-primary\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Ask Corvelan to Size the Separator<\/a><\/div><\/div><\/div><\/div><\/section>\r\n<section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-grid-2\"><div class=\"cl-media\"><img decoding=\"async\" alt=\"Representative air-cooled electromagnetic separator showing external cooling fan and equipment enclosure\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-fan-access-202609202301-c6a9f4.webp\"><\/div><div><div class=\"cl-eyebrow\">Cleaning &amp; Maintenance<\/div><h2>How do you clean and maintain it?<\/h2><p>Plan fan access and iron removal when you plan the installation. The separator also needs enough room for safe cleaning, inspection and service.<\/p><ul><li>Keep the cooling-air path and fan service area clear.<\/li><li>Use periodic cleaning only when tramp loading is low enough and planned stops are practical.<\/li><li>Use a self-cleaning separator when the line needs automatic, continuous iron discharge.<\/li><li>Provide a clear discharge area so removed iron cannot fall back into the material.<\/li><li>Follow site lockout\/tagout requirements and the supplied operating instructions before inspection or service.<\/li><\/ul><\/div><\/div><div class=\"cl-media\" style=\"margin-top:28px\"><img decoding=\"async\" alt=\"Diagram comparing periodic-cleaning and self-cleaning electromagnetic separator routes as project alternatives\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-cleaning-routes.webp\"><\/div><\/div><\/section>\r\n<section class=\"cl-section cl-soft\">\r\n<div class=\"cl-inner\">\r\n<div class=\"cl-eyebrow\">Before You Order<\/div>\r\n<h2>What should be checked before you approve the separator?<\/h2>\r\n<p>We keep the conveyor data, drawing and any agreed test condition tied to the same setup. This helps prevent a mismatch between the quoted separator and the real installation.<\/p>\r\n<div class=\"cl-grid-4\">\r\n<div class=\"cl-card\">\r\n<h3>Application record<\/h3>\r\n<p>Record belt width, belt speed, material depth, real working distance and the target tramp iron.<\/p>\r\n<\/div>\r\n<div class=\"cl-card\">\r\n<h3>GA and interface check<\/h3>\r\n<p>Check overall size, support points, lifting points, service space and electrical interfaces on the selected general arrangement drawing.<\/p>\r\n<\/div>\r\n<div class=\"cl-card\">\r\n<h3>Inspection points<\/h3>\r\n<p>Define which dimensions, cooling parts, wiring items and identification details need to be checked before shipment.<\/p>\r\n<\/div>\r\n<div class=\"cl-card\">\r\n<h3>Agreed test condition<\/h3>\r\n<p>If a magnetic or capture test is needed, define the target piece, distance, position and pass condition before the order.<\/p>\r\n<\/div>\r\n<\/div>\r\n<div class=\"cl-note\"><strong>Keep the test condition with the result:<\/strong> A Gauss reading or capture result needs a clear test condition. Record the measurement position, working distance and test target.<\/div>\r\n<\/div>\r\n<\/section>\r\n<section class=\"cl-section\">\r\n<div class=\"cl-inner\">\r\n<div class=\"cl-eyebrow\">Drawings and Inspection Records<\/div>\r\n<h2>What evidence can support the selected setup?<\/h2>\r\n<p>Tell us which drawings, inspection records or performance tests your purchase requires. We will confirm what is included in the quotation. We only publish measured results with the test condition stated.<\/p>\r\n<div class=\"cl-evidence-grid\">\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Drawing<\/div>\r\n<h3>General arrangement drawing<\/h3>\r\n<p>Use the GA drawing to confirm the final size, lifting points, support position, service space and quoted interfaces.<\/p>\r\n<\/div>\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Product<\/div>\r\n<h3>Real equipment photos<\/h3>\r\n<p>Use real product views to check the enclosure, cooling-fan arrangement, suspension points and service access.<\/p>\r\n<\/div>\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Inspection<\/div>\r\n<h3>Dimension and interface checks<\/h3>\r\n<p>Where required, the inspection scope can identify the dimensions and interfaces that must match the approved drawing.<\/p>\r\n<\/div>\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Electrical &amp; Cooling<\/div>\r\n<h3>Electrical and cooling checks<\/h3>\r\n<p>Project checks can cover the quoted electrical package, fan arrangement and the items agreed before shipment.<\/p>\r\n<\/div>\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Magnetic<\/div>\r\n<h3>Magnetic field measurement<\/h3>\r\n<p>If a field reading is required, the record should state the measurement point and distance. Surface Gauss alone does not show conveyor performance.<\/p>\r\n<\/div>\r\n<div class=\"cl-evidence-card\">\r\n<div class=\"cl-kicker\">Capture<\/div>\r\n<h3>Defined capture test<\/h3>\r\n<p>If capture testing is part of the project, define the test before the order. State the test piece, weight, working distance, orientation and running condition.<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/section><section class=\"cl-section cl-soft\">\r\n<div class=\"cl-inner\">\r\n<div class=\"cl-eyebrow\">Installation Examples<\/div>\r\n<h2>How should you compare a real separator application?<\/h2>\r\n<p>Do not compare projects by industry name alone. A useful case should show the conveyor conditions, target tramp iron, selected setup and the way the result was checked.<\/p>\r\n<div class=\"cl-table-wrap\">\r\n<table>\r\n<thead>\r\n<tr><th>Case information<\/th><th>Why it matters<\/th><th>What should be recorded<\/th><\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr><td>Material and Installation Location<\/td><td>Shows what the separator is protecting or cleaning.<\/td><td>Material type and whether the unit is before a crusher, mill, transfer point or other conveyor position.<\/td><\/tr>\r\n<tr><td>Belt width and belt speed<\/td><td>Defines conveyor coverage and exposure time.<\/td><td>Actual operating width and speed.<\/td><\/tr>\r\n<tr><td>Burden depth and real working distance<\/td><td>Shows how far the magnetic field must reach.<\/td><td>Normal and maximum material depth plus the distance to the hardest target position.<\/td><\/tr>\r\n<tr><td>Target tramp iron<\/td><td>Different pieces are not equally easy to capture.<\/td><td>Material, size, shape, weight and expected frequency.<\/td><\/tr>\r\n<tr><td>Installation and cleaning method<\/td><td>Changes discharge space and service needs.<\/td><td>Inline or crossbelt position and periodic or self-cleaning method.<\/td><\/tr>\r\n<tr><td>Result evidence<\/td><td>Shows what was actually checked.<\/td><td>Measured test result, inspection record, captured-iron photo or other stated evidence.<\/td><\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div>\r\n<div class=\"cl-note\"><strong>A photo is not enough by itself:<\/strong> A project example is most useful when the working distance, target tramp iron and operating condition are known. If the result is measured, the test method should be stated with it.<\/div>\r\n<\/div>\r\n<\/section><section class=\"cl-section\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Why Corvelan<\/div><h2>How does Corvelan select the right separator?<\/h2><p>You do not need to choose a separator from Gauss alone. Send us the conveyor and tramp-iron details. We use them to choose the magnetic setup, cooling method and cleaning method. The quoted equipment is then tied to the drawing and agreed checks.<\/p><div class=\"cl-steps\"><div class=\"cl-step\"><h3>Review the conveyor<\/h3><p>Belt width, speed, burden, headroom and installation position.<\/p><\/div><div class=\"cl-step\"><h3>Define the tramp iron<\/h3><p>Target material, piece size, weight and expected loading frequency.<\/p><\/div><div class=\"cl-step\"><h3>Choose the setup<\/h3><p>Air-cooled electromagnetic setup, cleaning method and installation direction.<\/p><\/div><div class=\"cl-step\"><h3>Check integration<\/h3><p>Support, clearance, discharge, electrical interface and service access.<\/p><\/div><div class=\"cl-step\"><h3>Confirm the equipment and checks<\/h3><p>The quotation and GA drawing define the selected equipment. Agreed inspection or test items are listed with the project scope.<\/p><\/div><\/div><div class=\"cl-note\"><strong>What matters most:<\/strong> We size the separator for the real working distance and target tramp iron, not from one surface-Gauss number alone.<\/div><\/div><\/section>\r\n<section class=\"cl-section cl-soft\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Common Questions<\/div><h2>Air-cooled electromagnetic separator questions<\/h2>\r\n<details class=\"cl-faq\"><summary>What is an air-cooled electromagnetic separator?<\/summary><p>It uses electrical power to create a magnetic field that pulls iron and steel from conveyor-fed material. Fans carry heat away from the electromagnetic assembly while it runs.<\/p><\/details><details class=\"cl-faq\"><summary>What is the difference between air-cooled and oil-cooled electromagnetic separators?<\/summary><p>Both use an energized coil to create the magnetic field. Air-cooled designs use forced air to carry heat away. Oil-cooled designs use an oil cooling circuit. We compare the cooling method with the running time, site temperature, working distance and service needs.<\/p><\/details><details class=\"cl-faq\"><summary>Is air-cooled the same as self-cleaning?<\/summary><p>No. Air cooling tells you how the electromagnet removes heat. Self-cleaning tells you how captured iron is discharged. We check these two needs separately.<\/p><\/details><details class=\"cl-faq\"><summary>How high should the separator be above the conveyor?<\/summary><p>There is no single height for every conveyor. We use the real working distance: the distance from the magnetic face to the hardest target position inside the material. We also check safe clearance and the conveyor layout.<\/p><\/details><details class=\"cl-faq\"><summary>Does higher Gauss mean better tramp-iron removal?<\/summary><p>Not always. Gauss tells you the magnetic field strength at one measured point. It does not tell you by itself whether the separator can lift iron through your material bed. Working distance, iron size and shape, material depth and belt speed also matter.<\/p><\/details><details class=\"cl-faq\"><summary>What tramp iron can the separator remove?<\/summary><p>The main targets are iron and steel pieces such as bolts, tools, chain pieces and scrap. Send the expected size, shape, weight and amount so we can check the application.<\/p><\/details><details class=\"cl-faq\"><summary>When should I choose a self-cleaning electromagnetic separator?<\/summary><p>Choose a self-cleaning separator when tramp iron is frequent, the line needs automatic discharge or repeated cleaning stops are not practical. We then check the discharge belt, drive, guarding and discharge space.<\/p><\/details><details class=\"cl-faq\"><summary>What data should I send Corvelan to size the separator?<\/summary><p>Start with the material, target tramp iron, belt width, belt speed, material depth or working distance, and one installation photo or drawing. Add throughput, lump size, moisture, bulk density, site conditions, power supply and test requirements when available.<\/p><\/details>\r\n<details class=\"cl-faq\">\r\n<summary>Can Corvelan provide a magnetic or capture test for my project?<\/summary>\r\n<p>If your project needs a defined test, tell us before quotation. Give us the target piece, working distance and test condition. We can then confirm whether the selected equipment can include that test.<\/p>\r\n<\/details><\/div><\/section>\r\n<section class=\"cl-section cl-dark\"><div class=\"cl-inner\"><div class=\"cl-eyebrow\">Get a Recommendation<\/div><h2>Send us your conveyor data<\/h2><p class=\"cl-lead\">You do not need a finished specification. Send the belt width, belt speed, material depth or working distance, target tramp iron and one installation photo. That is enough for us to start.<\/p><div class=\"cl-rfq\"><div><h3>Send first<\/h3><ul class=\"cl-list-clean\"><li>Material and physical form<\/li><li>Target Tramp Iron \/ steel contamination<\/li><li>Conveyor belt width<\/li><li>Belt speed<\/li><li>Material depth or real working distance<\/li><li>Installation photo or drawing<\/li><\/ul><\/div><div><h3>Add when available<\/h3><ul class=\"cl-list-clean\"><li>Normal and peak throughput<\/li><li>Particle or lump size<\/li><li>Moisture and bulk density<\/li><li>Target size \/ weight \/ loading frequency<\/li><li>Ambient and dust conditions<\/li><li>Power supply, cleaning preference and acceptance requirement<\/li><li>Existing site photos, previous captured-iron photos or test requirements<\/li><\/ul><\/div><\/div><p>We use this information to check magnetic reach, cooling needs, installation direction and the iron-cleaning method before we confirm the equipment.<\/p><div class=\"cl-actions\"><a class=\"cl-btn cl-btn-primary\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Send Your Conveyor Data<\/a><\/div><\/div><\/section>\r\n<\/div>\r\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Product\",\"name\":\"Air-Cooled Electromagnetic Separator\",\"brand\":{\"@type\":\"Brand\",\"name\":\"Coverlan\"},\"description\":\"Coverlan air-cooled electromagnetic separator for removing iron and steel tramp metal from conveyor-fed bulk materials. We choose the setup from belt width, real working distance, material depth, belt speed, target tramp iron and cleaning needs.\",\"category\":\"Magnetic Separation Equipment\",\"image\":[\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-hero-202609202301-a7f3c2.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-cooling-202609202301-b4d8e1.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-fan-access-202609202301-c6a9f4.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-mounting-202609202301-d2e7b5.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-working-principle.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-installation-variables.webp\",\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/air-cooled-electromagnetic-separator-cleaning-routes.webp\"],\"additionalProperty\":[{\"@type\":\"PropertyValue\",\"name\":\"Magnetic source\",\"value\":\"Electromagnetic\"},{\"@type\":\"PropertyValue\",\"name\":\"Cooling route\",\"value\":\"Air-cooled\"},{\"@type\":\"PropertyValue\",\"name\":\"Primary target\",\"value\":\"Iron and steel tramp metal\"},{\"@type\":\"PropertyValue\",\"name\":\"Cleaning route\",\"value\":\"Cleaning method selected separately from cooling method\"}]}<\/script>\r\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is an air-cooled electromagnetic separator?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It uses electrical power to create a magnetic field that pulls iron and steel from conveyor-fed material. Fans carry heat away from the electromagnetic assembly while it runs.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between air-cooled and oil-cooled electromagnetic separators?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Both use an energized coil to create the magnetic field. Air-cooled designs use forced air to carry heat away. Oil-cooled designs use an oil cooling circuit. We compare the cooling method with the running time, site temperature, working distance and service needs.\"}},{\"@type\":\"Question\",\"name\":\"Is air-cooled the same as self-cleaning?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Air cooling tells you how the electromagnet removes heat. Self-cleaning tells you how captured iron is discharged. We check these two needs separately.\"}},{\"@type\":\"Question\",\"name\":\"How high should the separator be above the conveyor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"There is no single height for every conveyor. We use the real working distance: the distance from the magnetic face to the hardest target position inside the material. We also check safe clearance and the conveyor layout.\"}},{\"@type\":\"Question\",\"name\":\"Does higher Gauss mean better tramp-iron removal?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Not always. Gauss tells you the magnetic field strength at one measured point. It does not tell you by itself whether the separator can lift iron through your material bed. Working distance, iron size and shape, material depth and belt speed also matter.\"}},{\"@type\":\"Question\",\"name\":\"What tramp iron can the separator remove?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The main targets are iron and steel pieces such as bolts, tools, chain pieces and scrap. Send the expected size, shape, weight and amount so we can check the application.\"}},{\"@type\":\"Question\",\"name\":\"When should I choose a self-cleaning electromagnetic separator?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose a self-cleaning separator when tramp iron is frequent, the line needs automatic discharge or repeated cleaning stops are not practical. We then check the discharge belt, drive, guarding and discharge space.\"}},{\"@type\":\"Question\",\"name\":\"What data should I send Coverlan to size the separator?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Start with the material, target tramp iron, belt width, belt speed, material depth or working distance, and one installation photo or drawing. Add throughput, lump size, moisture, bulk density, site conditions, power supply and test requirements when available.\"}},{\"@type\":\"Question\",\"name\":\"Can Coverlan provide a magnetic or capture test for my project?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"If your project needs a defined test, tell us before quotation. Give us the target piece, working distance and test condition. We can then confirm whether the selected equipment can include that test.\"}}]}<\/script>\n\n\t\t\t\t<\/div>\n\t\t\n<\/div>\n\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Air-Cooled Suspended Electromagnetic Separator Conveyor Tramp-Iron Removal Corvelan air-cooled electromagnetic separators remove unwanted iron and steel from material moving on a conveyor. The electromagnet uses forced air to carry heat away while it runs. We choose the setup from your belt width, working distance, material depth, belt speed and target tramp iron. Best ForConveyor-fed bulk [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4341,"parent":0,"menu_order":32,"comment_status":"open","ping_status":"open","template":"elementor_header_footer","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"product-category":[41],"class_list":["post-4554","product","type-product","status-publish","format-standard","has-post-thumbnail","hentry","product-category-magnetic-separation-equipment"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/product\/4554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/comments?post=4554"}],"version-history":[{"count":5,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/product\/4554\/revisions"}],"predecessor-version":[{"id":5275,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/product\/4554\/revisions\/5275"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media\/4341"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/media?parent=4554"}],"wp:term":[{"taxonomy":"product-category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/es\/wp-json\/wp\/v2\/product-category?post=4554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}