{"id":5203,"date":"2026-09-23T09:01:34","date_gmt":"2026-09-23T01:01:34","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5203"},"modified":"2026-11-16T17:13:09","modified_gmt":"2026-11-16T09:13:09","slug":"gauss-vs-pull-force","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/fr\/gauss-vs-pull-force\/","title":{"rendered":"La mesure du courant d\u2019un \u00e9lectroaimant permet-elle de confirmer ses performances de captation des ferrailles ind\u00e9sirables ?"},"content":{"rendered":"\n<style>\n.cv-pickup {\n  --cv-blue: #0b4f8a;\n  --cv-navy: #10233f;\n  --cv-text: #263548;\n  --cv-soft: #f3f7fb;\n  --cv-border: #d9e3ed;\n  color: var(--cv-text);\n  font: inherit;\n  font-size: 17px;\n  line-height: 1.75;\n  overflow-wrap: anywhere;\n}\n.cv-pickup > section, .cv-pickup > .cv-pickup-intro, .cv-pickup > nav {\n  display: block;\n  margin: 0 0 24px;\n  padding: 22px;\n  background: #fff;\n  border: 1px solid var(--cv-border);\n  border-top: 4px solid var(--cv-blue);\n  border-radius: 16px;\n  box-shadow: 0 3px 12px #10233f0d;\n}\n.cv-pickup > .cv-pickup-intro, .cv-pickup > nav { background: var(--cv-soft); }\n.cv-pickup h2, .cv-pickup h3 {\n  color: var(--cv-navy);\n  line-height: 1.3;\n}\n.cv-pickup h2 { font-size: 30px; margin: 0 0 12px; }\n.cv-pickup h3 { font-size: 24px; margin: 22px 0 8px; }\n.cv-pickup p { margin: 0 0 13px; }\n.cv-pickup section > p:last-child, .cv-pickup .cv-pickup-intro > p:last-child { margin-bottom: 0; }\n.cv-pickup section[id], .cv-pickup h3[id] { scroll-margin-top: 100px; }\n.cv-pickup a { color: var(--cv-blue); text-decoration: underline; text-underline-offset: 0.15em; }\n.cv-pickup a:focus-visible, .cv-pickup summary:focus-visible, .cv-pickup .cv-pickup-table:focus-visible {\n  outline: 2px solid var(--cv-blue);\n  outline-offset: 3px;\n}\n.cv-pickup summary { color: var(--cv-navy); font-weight: 700; cursor: pointer; }\n.cv-pickup nav ol { margin: 9px 0 0; padding-inline-start: 25px; }\n.cv-pickup nav li + li { margin-top: 4px; }\n.cv-pickup .cv-pickup-media {\n  display: block;\n  float: none;\n  clear: both;\n  margin: 10px 0 15px;\n}\n.cv-pickup .cv-pickup-media img {\n  display: block;\n  float: none;\n  max-width: 100%;\n  height: auto;\n  margin-inline: auto;\n  border-radius: 8px;\n}\n.cv-pickup .cv-pickup-table { overflow-x: auto; margin: 14px 0; }\n.cv-pickup table { border-collapse: collapse; min-width: 34rem; }\n.cv-pickup th, .cv-pickup td {\n  padding: 9px 11px;\n  text-align: start;\n  vertical-align: top;\n  border: 1px solid var(--cv-border);\n}\n.cv-pickup thead th { color: var(--cv-navy); background: var(--cv-soft); }\n.cv-pickup tbody tr:nth-child(even) { background: #f9fbfd; }\n.cv-pickup #faq details { border-top: 1px solid var(--cv-border); padding: 11px 0; }\n.cv-pickup #faq details:last-child { padding-bottom: 0; }\n.cv-pickup #faq details > p { margin: 8px 0 0; }\n@media (max-width: 767px) {\n  .cv-pickup { font-size: 16px; }\n  .cv-pickup > section, .cv-pickup > .cv-pickup-intro, .cv-pickup > nav {\n    margin-bottom: 18px;\n    padding: 18px;\n    border-top-width: 3px;\n    border-radius: 12px;\n  }\n  .cv-pickup h2 { font-size: 24px; }\n  .cv-pickup h3 { font-size: 20px; }\n}\n<\/style>\n<article class=\"cv-pickup\" lang=\"en-US\">\n<div class=\"cv-pickup-intro\">\n<p><strong>No. A normal DC coil-current reading shows that a suspended electromagnet is drawing the expected current at that moment. A guarded trial with representative tramp iron in moving feed shows whether the separator can lift it out and keep it out of the product stream.<\/strong> If iron is still reaching your crusher, record the voltage and current after the magnet warms up, then find out whether the iron stayed in the burden, fell back after pickup, or missed the reject chute.<\/p>\n<p>Tramp iron is unwanted ferrous material, such as a bolt, broken tooth, or steel fragment, traveling with the feed. A separator has to reach that piece through the load, lift it in the time available, and either hold it for cleaning or deliver it to a reject point. If your checks already include <a href=\"#gauss-vs-pull-force\">gauss or pull force<\/a>, use the comparison below to decide which measurement belongs next to the current reading.<\/p>\n<\/div><nav aria-label=\"On this page\" data-article-section=\"navigation\"><details><summary>On this page<\/summary><ol><li><a href=\"#electromagnet-current\">What Does Electromagnet Current Tell You About Magnetic Pickup Performance?<\/a><\/li><li><a href=\"#coil-readings\">Which Amps Should You Read on a Suspended Electromagnet?<\/a><\/li><li><a href=\"#hot-current\">Why Can Electromagnet Current Change as the Coil Warms Up?<\/a><\/li><li><a href=\"#more-current\">Will More Electromagnet Current Improve Tramp-Iron Pickup?<\/a><\/li><li><a href=\"#working-gap\">Why Can a Magnet With Normal Current Miss Iron in the Burden?<\/a><\/li><li><a href=\"#gauss-vs-pull-force\">Gauss vs. Pull Force: Which Measurement Helps Diagnose Weak Pickup?<\/a><\/li><li><a href=\"#tramp-iron-targets\">Which Tramp-Iron Pieces Should the Separator Be Able to Pick Up?<\/a><\/li><li><a href=\"#pickup-and-discharge\">How Can You Tell a Pickup Problem From a Discharge Problem?<\/a><\/li><li><a href=\"#pickup-test\">How Do You Prove Tramp-Iron Pickup Before Accepting the Magnet?<\/a><\/li><li><a href=\"#weak-pickup\">What Should You Check First When Iron Still Gets Through?<\/a><\/li><li><a href=\"#faq\">Frequently Asked Questions<\/a><\/li><\/ol><\/details><\/nav>\n<section id=\"electromagnet-current\">\n<h2>What Does Electromagnet Current Tell You About Magnetic Pickup Performance?<\/h2>\n<p><strong>Coil current is an electrical check. It tells you how much current is flowing through the winding, which helps you check whether the magnet is being energized as expected.<\/strong> The winding and the magnet\u2019s steel core and poles determine how that excitation produces a field around the conveyor. On the same unit, at the same operating state, a change in current can help explain a change in the field. Two different magnets can draw the same current and produce very different fields where the iron travels.<\/p>\n<h3>What does a normal reading confirm?<\/h3>\n<p><strong>It confirms that the measured coil current is in the range specified for that measurement point and operating state.<\/strong> Compare the reading with the OEM specification or the commissioning record for the same magnet, rectifier, and cold or warm condition. A normal value puts your next checks on the working height, the burden and the iron\u2019s path to the bin. It also gives your electrician a reference for spotting a change later.<\/p>\n<h3>What proves the iron was removed?<\/h3>\n<p><strong>The result that matters is where the target ended up.<\/strong> On a self-cleaning unit, look for it at the designated reject outlet. On a manual-clean unit, confirm that it stays captured until a controlled cleanout. A piece can jump toward a magnet and still fall onto the carrying belt. The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf#page=13\" rel=\"nofollow noopener\" target=\"_blank\">Eriez suspended electromagnet manual, Table 1<\/a>, treats supply voltage, suspension height, target material, nearby steel and overheating as separate troubleshooting checks.<\/p>\n<\/section>\n<section id=\"coil-readings\">\n<h2>Which Amps Should You Read on a Suspended Electromagnet?<\/h2>\n<p><strong>Use an actual reading from the DC magnet circuit, at the OEM\u2019s specified measurement point.<\/strong> A rectifier supplies DC to the coil. The panel can also show the incoming AC supply, a commanded current, or the motor current of the self-cleaning belt. Identify the signal before comparing its number with the magnet nameplate or changing an alarm setting.<\/p>\n<h3>How do you match the panel display to the coil?<\/h3>\n<p><strong>Use the wiring diagram and the meter or PLC tag description to identify the circuit and the signal type.<\/strong> A setpoint shows what the controller requests, while a feedback signal shows what its sensor reports. A reading from the separate belt motor can help diagnose a stalled discharge belt. Keep it on a different line in the log from coil amps.<\/p>\n<h3>What belongs beside the current reading?<\/h3>\n<p><strong>Record the DC voltage alongside the amps, with the unit ID, elapsed run time, cooling status and test condition.<\/strong> Use existing approved indications where available. Qualified personnel should verify suspect indications at the OEM-specified points under site electrical procedures. The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf#page=12\" rel=\"nofollow noopener\" target=\"_blank\">Eriez rectifier and troubleshooting instructions<\/a> distinguish control supply checks from DC checks at the magnet.<\/p>\n<\/section>\n<section id=\"hot-current\">\n<h2>Why Can Electromagnet Current Change as the Coil Warms Up?<\/h2>\n<p><strong>As the winding heats up, its resistance rises. At roughly constant DC voltage, that can lower coil current during a run.<\/strong> Compare startup readings with the startup baseline and steady readings with the OEM\u2019s hot operating range or the verified baseline for that unit. Run time and cooling status help show whether two readings were taken under comparable conditions. The relationship follows from <a href=\"https:\/\/openstax.org\/books\/university-physics-volume-2\/pages\/9-3-resistivity-and-resistance\" rel=\"nofollow noopener\" target=\"_blank\">how metal resistance changes with temperature<\/a>. The operating range still comes from the magnet and rectifier supplier.<\/p>\n<h3>How do you tell warmup from a supply or cooling problem?<\/h3>\n<p><strong>Follow voltage, current and the cooling indications together.<\/strong> If voltage and current drop together, have electrical maintenance check the supply path and rectifier. If voltage stays close to its baseline while current falls farther than usual, check the unit\u2019s thermal history and cooling indications with maintenance. Use the checks that match the design. Air cooling, natural oil circulation and pumped oil cooling have <a href=\"https:\/\/www.corvelanmag.com\/electromagnetic-separator-cooling-methods\/\">different heat paths and service checks<\/a>. If the unit starts dropping iron after several hours, note the time and compare a cold pass with a stabilized hot trial under matched feed conditions. The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf#page=13\" rel=\"nofollow noopener\" target=\"_blank\">Eriez troubleshooting chart<\/a> gives guidance for its own units. Use the limits and reference state for your model and rectifier.<\/p>\n<h3>What if the rectifier holds current steady?<\/h3>\n<p><strong>A current-regulated supply can hold the same amps as winding resistance rises, provided it has enough voltage available.<\/strong> Look at the voltage trend, controller limit indications and cooling status. A flat current trend can coincide with a rising required voltage. If the supply reaches its limit or a cooling alarm appears, follow the OEM procedure before resuming a pickup trial.<\/p>\n<\/section>\n<section id=\"more-current\">\n<h2>Will More Electromagnet Current Improve Tramp-Iron Pickup?<\/h2>\n<p><strong>Extra current can increase magnetic excitation on the same magnet within its approved operating range. Start by restoring any electrical shortfall to the specified range, then verify pickup under load.<\/strong> The same increase in amps can give different field gains at different operating points. If part of the steel core is close to magnetic saturation, additional current yields a smaller gain there and increases winding heat at a given resistance.<\/p>\n<h3>When is an electrical correction the first step?<\/h3>\n<p><strong>Investigate the electrical side first when verified coil voltage or current falls outside the specified range for that state.<\/strong> Have maintenance check the supply, rectifier, cooling and winding as directed by the manufacturer. Once the electrical readings are back in range, run the same pickup test that exposed the problem.<\/p>\n<h3>Why do amps and kilowatts compare poorly across different magnets?<\/h3>\n<p><strong>Different windings have different numbers of turns, and different pole and core designs put the field in different places.<\/strong> The same DC amps can produce different ampere-turns, which describe how strongly the coil drives the magnetic circuit. The usable field at the target also depends on the geometry. Give suppliers the same conveyor drawing and the same target set so their offers address the same job. Compare their proposed installation and test conditions along with electrical and cooling requirements.<\/p>\n<\/section>\n<section id=\"working-gap\">\n<h2>Why Can a Magnet With Normal Current Miss Iron in the Burden?<\/h2><div class=\"cv-pickup-media\"><img loading=\"lazy\" alt=\"Why Can a Magnet With Normal Current Miss Iron in the Burden?\" decoding=\"async\" height=\"750\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-crossbelt-magnetic-separator-installation-20260907-075204-2.webp\" width=\"1000\"\/><\/div>\n<p><strong>A target buried deep in the material can be too far from the working face, or have too little time to rise before it moves past the useful part of the field.<\/strong> The burden is the layer of material carried on the belt. On a loaded conveyor, a target near the belt can be much harder to lift than the same piece lying on top.<\/p>\n<h3>Which distances should you put on the conveyor drawing?<\/h3>\n<p><strong>Record the magnet reference face to the carrying belt and the clearance to the highest credible burden or lump.<\/strong> Identify whether the OEM measures from the magnet face or another working surface, and show where the self-cleaning belt passes. Then mark the depth and belt position of the target. A gap to the top of the load can look generous while the lift distance from the bottom is too large. Before changing height, confirm room for the highest lump, belt movement and tramp-iron discharge. See <a href=\"https:\/\/www.corvelanmag.com\/magnetic-separator-working-distance\/\">how to check burden depth and magnet clearance<\/a>.<\/p>\n<h3>When does the mounting position change the result?<\/h3>\n<p><strong>A head-pulley installation can give iron a freer path out as material leaves the conveyor. An over-belt installation has to lift the same piece through the moving burden.<\/strong> For the head-pulley layout, check the actual discharge trajectory at operating speed and flow. For a crossbelt layout, check the belt centerline, trough, loaded profile and nearby steel against the OEM drawing. A change in idlers or steelwork can affect where iron is drawn. For geometry and speed effects, see the <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf#page=6\" rel=\"nofollow noopener\" target=\"_blank\">Eriez installation instructions, pp. 6\u20138<\/a>, and its <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/SB-305-Eriez-Suspended-Magnet.pdf\" rel=\"nofollow noopener\" target=\"_blank\">suspended magnet selection guide<\/a>.<\/p>\n<\/section>\n<section id=\"gauss-vs-pull-force\">\n<h2>Gauss vs. Pull Force: Which Measurement Helps Diagnose Weak Pickup?<\/h2>\n<p><strong>Use gauss to check the field at specified points, pull force to check the hold on a defined steel piece, and a moving-feed trial to check removal.<\/strong> Match the check to the symptom before asking a supplier for a larger number.<\/p>\n<h3 id=\"field-measurement\">Where should a gauss reading be taken?<\/h3><div class=\"cv-pickup-media\"><img loading=\"lazy\" alt=\"Where should a gauss reading be taken?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-qc-gauss-meter-test-20260906-182936-2-1.webp\" width=\"1200\"\/><\/div>\n<p><strong>Compare readings at agreed points and distances from the same reference surface, with a consistent probe direction and magnet state.<\/strong> A surface peak can be useful as a repeatable production or service check. To investigate buried iron or repeated edge misses, ask for points at the corresponding working distances and across the relevant belt width. One surface reading cannot describe how the field changes along the target\u2019s path. Readings at several defined positions show where it changes quickly. See <a href=\"https:\/\/www.corvelanmag.com\/magnetic-field-gradient-vs-gauss\/\">how field gradient differs from a single gauss reading<\/a>.<\/p>\n<h3 id=\"pull-force-test\">What makes a pull-force reading repeatable?<\/h3><div class=\"cv-pickup-media\"><img loading=\"lazy\" alt=\"What makes a pull-force reading repeatable?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/magnetic-separator-pull-force-test-2.webp\" width=\"1200\"\/><\/div>\n<p><strong>Use the same test piece, location, gap and pull direction in an OEM-approved fixture or method.<\/strong> Record the peak breakaway force and the test state. The <a href=\"https:\/\/assets.magnetics.com\/assets\/files\/manuals\/900290_RevB_PullTestKit.pdf#page=2\" rel=\"nofollow noopener\" target=\"_blank\">Industrial Magnetics pull-test manual<\/a> explains why the test-piece and spacer depend on the separator geometry. <a href=\"https:\/\/www.eriez.com\/Products\/Magnetic-Separation\/Magnetic-Separation-for-Tramp-Metal\/Small-Magnetic-Separation\/Pull-Test-Kits\" rel=\"nofollow noopener\" target=\"_blank\">Eriez\u2019s pull-test guidance<\/a> uses repeat measurements to track changes over time. On a suspended electromagnet, use a controlled, approved setup for any energized measurement. The holding force on a static piece and the ability to extract a moving piece at depth answer different questions.<\/p>\n<\/section>\n<section id=\"tramp-iron-targets\">\n<h2>Which Tramp-Iron Pieces Should the Separator Be Able to Pick Up?<\/h2>\n<p><strong>Specify both the hardest piece you need to remove and the piece that would cause the most damage downstream.<\/strong> They may be different. A compact bolt buried near the belt can be a difficult pickup. A long broken steel tooth can be easier to attract and harder to pass through the space between the separator and the reject chute.<\/p>\n<h3>What should you record about the target?<\/h3>\n<p><strong>Describe material, shape, dimensions, mass and likely burial depth or position.<\/strong> Use examples that match the iron you actually find, including different orientations if they occur in service. Note whether the piece is free or attached to other material. If a missed item\u2019s composition is uncertain, have it identified in a safe inspection area. The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/SB-305-Eriez-Suspended-Magnet.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez selection guide\u2019s tramp-metal collection section<\/a> identifies size, shape, belt speed and burden depth as selection factors.<\/p>\n<h3>How should you handle a different metal or attached piece?<\/h3>\n<p><strong>Set separate requirements when the line must catch both ferrous iron and metal the magnet may leave behind.<\/strong> Some stainless grades respond weakly and others can be magnetic. If the target remains attached to a lump or other scrap, include that representative assembly in your test plan. For nonmagnetic contaminants that must trigger line protection, review a separate <a href=\"https:\/\/www.corvelanmag.com\/product-category\/conveyor-metal-detector\/\">conveyor metal detection<\/a> step and its actual response at the required product and belt conditions.<\/p>\n<\/section>\n<section id=\"pickup-and-discharge\">\n<h2>How Can You Tell a Pickup Problem From a Discharge Problem?<\/h2>\n<p><strong>Find the first point where the iron leaves the intended route.<\/strong> If it never rises, check excitation and the path from the burden to the magnet. If it rises and falls back or ends up in the wrong place, check how the separator holds, carries and releases it.<\/p>\n<h3>What changes with a manual-clean magnet?<\/h3>\n<p><strong>Check whether pickup deteriorates as the face fills up between cleanouts.<\/strong> Compare early operation with the end of the planned cleaning interval at similar loading. If misses cluster late in the interval, review the actual iron arrivals and cleanout schedule before choosing a larger magnet. The <a href=\"https:\/\/www.corvelanmag.com\/products\/suspended-electromagnetic-separator\/\">Corvelan RCDB suspended electromagnet<\/a> is a manual-clean option for intermittent iron loading where planned cleaning fits the line. Use the manufacturer\u2019s approved shutdown and discharge sequence, with personnel clear of falling iron.<\/p>\n<h3>What changes with a self-cleaning crossbelt?<\/h3>\n<p><strong>Follow the iron from pickup to the side discharge and into the bin.<\/strong> From a guarded position, look for stalled or mis-tracking discharge belts, a target snagging at the clearance, or a chute or splitter sending it back toward the product. The <a href=\"https:\/\/www.corvelanmag.com\/products\/self-cleaning-cross-belt-electromagnetic-separator\/\">Corvelan self-cleaning crossbelt electromagnets<\/a> provide continuous discharge configurations. Compare options using the peak iron load, largest piece to discharge and available chute space. The <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-323-Eriez-Suspend-Electromagnet-IOM.pdf#page=14\" rel=\"nofollow noopener\" target=\"_blank\">Eriez manual\u2019s adjustment guide<\/a> distinguishes buildup, positioning and discharge clearance. For recurring tracking or wear, use the <a href=\"https:\/\/www.corvelanmag.com\/overband-magnet-maintenance\/\">self-cleaning overband maintenance guide<\/a> to narrow down the belt and guide surfaces to inspect.<\/p>\n<\/section>\n<section id=\"pickup-test\">\n<h2>How Do You Prove Tramp-Iron Pickup Before Accepting the Magnet?<\/h2>\n<p><strong>Agree on a guarded test plan in writing, then run it at the specified working gap with the separator warm and the conveyor carrying representative feed.<\/strong> A factory test can verify the agreed electrical, mechanical or trial conditions. If the factory cannot reproduce the installed conveyor and burden, reserve the loaded pickup and discharge acceptance for the site test. <a href=\"https:\/\/www.corvelanmag.com\/quality-control\/\">Corvelan\u2019s quality-control page<\/a> distinguishes electrical and operating checks from material trials agreed in the project scope.<\/p>\n<h3>What should the buyer and supplier agree on?<\/h3>\n<p><strong>Fix the test envelope, the target set and the definition of success before the run.<\/strong> List the installed position, belt speed, representative flow and burden profile, the steady operating state and the known target pieces. Include the deepest credible target position and a relevant edge or off-center position if the feed profile allows it. Set the number of trials per group and agree whether acceptance requires every designated high-consequence piece to reach the reject outlet. For a manual-clean unit, define how a held target will be verified at the safe cleanout point.<\/p>\n<p>Use an approved method for introducing and recovering targets with guards in place during operation. Protect downstream equipment with an approved recovery or interception arrangement. Keep people outside the attraction, pinch and drop zones. Use site isolation procedures for setup and retrieval where exposure exists. If equipment must be energized during servicing for testing, use the site\u2019s controlled test procedure and applicable requirements. In the US, see <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.147\" rel=\"nofollow noopener\" target=\"_blank\">OSHA 29 CFR 1910.147(d) and (f)(1)<\/a>.<\/p>\n<h3>How do you score a loaded pickup test?<\/h3>\n<p><strong>Count recovered targets out of targets introduced for each test group, and document where each miss went.<\/strong> For example, assume an approved test uses 10 bolts on the surface and 10 near the bottom of a representative burden. If all 10 surface bolts and seven buried bolts reach the reject bin, record 10\/10 at the surface and 7\/10 at depth. The combined result is 17\/20, or 85% by count. A result by count gives each test piece equal weight, so keep the results separate by target class and position when performance requirements differ. If the agreed buried-bolt requirement is 10\/10, the installation fails that condition. Check clearance, burden and mounting and then repeat the affected group at the agreed belt speed. A target that cannot be accounted for needs investigation under the test plan before the run can be signed off.<\/p>\n<\/section>\n<section id=\"weak-pickup\">\n<h2>What Should You Check First When Iron Still Gets Through?<\/h2>\n<p><strong>Use the timing and location of the miss to choose your first check.<\/strong> Compare a passing run with the run that failed. Record what actually changed, and repeat the failure condition after a correction.<\/p>\n<div aria-label=\"Troubleshooting by symptom\" class=\"cv-pickup-table\" role=\"region\" tabindex=\"0\"><table>\n<thead><tr><th scope=\"col\">What you see<\/th><th scope=\"col\">First check<\/th><th scope=\"col\">What to repeat<\/th><\/tr><\/thead>\n<tbody>\n<tr><th scope=\"row\">DC volts and amps both fall<\/th><td>Compare actual DC readings with the OEM state and check the supply and rectifier with qualified personnel.<\/td><td>Repeat the warm readings and loaded target trial after correction.<\/td><\/tr>\n<tr><th scope=\"row\">Pickup weakens as the shift goes on<\/th><td>Compare the hot baseline, cooling indications, peak feed and iron buildup. Identify which changes with the miss.<\/td><td>Repeat after warmup, at the same burden and time in the cleaning cycle.<\/td><\/tr>\n<tr><th scope=\"row\">Surface targets pass, buried or edge targets miss<\/th><td>Measure the loaded cross-section, target depth and width position against the working face. Check belt speed and the allowed installation envelope.<\/td><td>Repeat the failed depth or edge group with the same target and agreed feed.<\/td><\/tr>\n<tr><th scope=\"row\">Iron lifts and drops back<\/th><td>Use guarded observation to trace the carry path, self-cleaning belt and reject chute, or manual-clean face buildup.<\/td><td>Verify end-to-end delivery during the relevant peak-load condition.<\/td><\/tr>\n<\/tbody>\n<\/table><\/div>\n<h3>What if the original failure cannot be repeated?<\/h3>\n<p><strong>Log the conditions the next time a miss occurs before making a second change.<\/strong> Record the target, belt speed, load profile, position, thermal state and which outlet it reached. Repeat a controlled trial at the closest safe equivalent. That gives the plant and the supplier a specific condition to investigate.<\/p>\n<h3>What should you send for a model or installation review?<\/h3>\n<p><strong>Start with the belt width and speed, maximum material depth, available mounting height and two or three representative targets.<\/strong> Add a side-view drawing or safe installation photos. For an existing problem, include the model, the cold and warm DC voltage and current, when the miss happened and what was recovered. <a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Send us your conveyor and tramp-iron details<\/a> to review the installation inputs and discuss a suitable manual-clean or self-cleaning configuration and the checks to agree before quotation.<\/p>\n<\/section>\n<section data-article-section=\"conclusion\" id=\"conclusion\">\n<h2>Put the Electrical Reading Beside the Pickup Result<\/h2>\n<p><strong>Keep the coil-current trend with the maintenance record and the loaded removal result with the acceptance record.<\/strong> If amps are in range but iron gets through, trace the same target from its position in the burden to the reject point. That tells you whether to examine reach, holding or discharge before changing the magnet or its settings.<\/p>\n<\/section>\n<section class=\"faq\" data-article-section=\"faq\" id=\"faq\">\n<h2>Frequently Asked Questions<\/h2>\n<details><summary>Does a green \u201cmagnet on\u201d light mean the coil is drawing current?<\/summary><p><strong>Only if the light is driven by actual coil-current feedback.<\/strong> If it follows an on command or a contactor indication, confirm the actual feedback signal before using it in a fault investigation.<\/p><\/details>\n<details><summary>Should we keep our old amp baseline after replacing the panel meter?<\/summary><p><strong>Carry it forward after you compare the new indication with a verified reference under the same operating state.<\/strong> Check scaling and measurement point. If there is a difference, record the change date and establish a new baseline before interpreting trends across the meter replacement.<\/p><\/details>\n<details><summary>Can I use the case temperature to tell how hot the winding is?<\/summary><p><strong>Use case temperature as a trend at a documented spot if the OEM permits it.<\/strong> The case temperature can differ from winding temperature and changes with airflow, ambient conditions and cooling design. Use the designated sensor or OEM procedure to assess thermal limits.<\/p><\/details>\n<details><summary>Do we need a new pickup test after moving the magnet?<\/summary><p><strong>Repeat the affected pickup and discharge checks if the move changes the height, angle, alignment or material trajectory.<\/strong> Mark the new dimensions on the drawing first. The previous test result applies to the previous installation geometry.<\/p><\/details>\n<details><summary>Can a flat steel plate stand in for a bolt in an acceptance test?<\/summary><p><strong>Use the plate as a separate reference piece if the approved test defines it that way.<\/strong> Include a representative bolt in the loaded trial if bolts are the risk. Its shape, orientation and chance of being buried change the extraction task.<\/p><\/details>\n<details><summary>What should we verify after an emergency stop interrupts a trial?<\/summary><p><strong>Follow the plant\u2019s stop and restart procedure, then reconcile where any test pieces are before running a new trial.<\/strong> Check the indications for both the coil and the discharge belt. Treat the interrupted test group according to the agreed repeat and scoring rules.<\/p><\/details>\n<details><summary>How can we test if there is no safe downstream recovery point?<\/summary><p><strong>Use a guarded test rig or arrange an approved interception point before introducing loose test pieces.<\/strong> Otherwise, document the available electrical and stationary checks and leave the loaded acceptance item open until the site has a safe test route.<\/p><\/details>\n<details><summary>What if we lose track of one numbered test piece?<\/summary><p><strong>Record it as unaccounted for and follow the agreed stop, search and reconciliation procedure.<\/strong> A missing target earns no recovery credit. Record the final location if found so a miss can be distinguished from lost test accountability.<\/p><\/details>\n<details><summary>Does a new hum explain why the magnet is missing iron?<\/summary><p><strong>A new sound gives you a time and place to investigate.<\/strong> From outside the guarded area, note whether it starts with the rectifier, the coil circuit, the cooling system or the discharge drive. Give maintenance that timing with the current trend and the pickup observations.<\/p><\/details>\n<details><summary>Can a coil-current alarm tell operators when to clean the magnet?<\/summary><p><strong>Use a conventional current alarm for electrical departures from an OEM-approved range.<\/strong> For a manual-clean alert tied to iron buildup, use the historical loading and cleanout results or a purpose-designed load monitor validated for that unit. For example, the <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-419-Eriez-Magnet-Load-Monitor-IOM.pdf#page=2\" rel=\"nofollow noopener\" target=\"_blank\">Eriez Series FS load monitor<\/a> senses a change in the fringe field as ferrous material builds up. Confirm the signal, setup and cleanout trigger with the OEM for your unit.<\/p><\/details>\n<\/section>\n\n<\/article>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a green \u201cmagnet on\u201d light mean the coil is drawing current?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Only if the light is driven by actual coil-current feedback. If it follows an on command or a contactor indication, confirm the actual feedback signal before using it in a fault investigation.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should we keep our old amp baseline after replacing the panel meter?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Carry it forward after you compare the new indication with a verified reference under the same operating state. Check scaling and measurement point. If there is a difference, record the change date and establish a new baseline before interpreting trends across the meter replacement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use the case temperature to tell how hot the winding is?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use case temperature as a trend at a documented spot if the OEM permits it. The case temperature can differ from winding temperature and changes with airflow, ambient conditions and cooling design. Use the designated sensor or OEM procedure to assess thermal limits.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do we need a new pickup test after moving the magnet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Repeat the affected pickup and discharge checks if the move changes the height, angle, alignment or material trajectory. Mark the new dimensions on the drawing first. The previous test result applies to the previous installation geometry.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a flat steel plate stand in for a bolt in an acceptance test?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use the plate as a separate reference piece if the approved test defines it that way. Include a representative bolt in the loaded trial if bolts are the risk. Its shape, orientation and chance of being buried change the extraction task.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What should we verify after an emergency stop interrupts a trial?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Follow the plant\u2019s stop and restart procedure, then reconcile where any test pieces are before running a new trial. Check the indications for both the coil and the discharge belt. Treat the interrupted test group according to the agreed repeat and scoring rules.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can we test if there is no safe downstream recovery point?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use a guarded test rig or arrange an approved interception point before introducing loose test pieces. Otherwise, document the available electrical and stationary checks and leave the loaded acceptance item open until the site has a safe test route.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What if we lose track of one numbered test piece?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Record it as unaccounted for and follow the agreed stop, search and reconciliation procedure. A missing target earns no recovery credit. Record the final location if found so a miss can be distinguished from lost test accountability.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a new hum explain why the magnet is missing iron?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A new sound gives you a time and place to investigate. From outside the guarded area, note whether it starts with the rectifier, the coil circuit, the cooling system or the discharge drive. Give maintenance that timing with the current trend and the pickup observations.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a coil-current alarm tell operators when to clean the magnet?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use a conventional current alarm for electrical departures from an OEM-approved range. For a manual-clean alert tied to iron buildup, use the historical loading and cleanout results or a purpose-designed load monitor validated for that unit. For example, the Eriez Series FS load monitor senses a change in the fringe field as ferrous material builds up. Confirm the signal, setup and cleanout trigger with the OEM for your unit.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>No. A normal DC coil-current reading shows that a suspended electromagnet is drawing the expected current at that moment. A guarded trial with representative tramp iron in moving feed shows whether the separator can lift it out and keep it out of the product stream. If iron is still reaching your crusher, record the voltage [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3928,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5203","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/comments?post=5203"}],"version-history":[{"count":5,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5203\/revisions"}],"predecessor-version":[{"id":6104,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5203\/revisions\/6104"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media\/3928"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media?parent=5203"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/categories?post=5203"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/tags?post=5203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}