{"id":5523,"date":"2026-11-04T17:30:21","date_gmt":"2026-11-04T09:30:21","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5523"},"modified":"2026-10-30T13:02:42","modified_gmt":"2026-10-30T05:02:42","slug":"overband-magnet-installation","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/fr\/overband-magnet-installation\/","title":{"rendered":"Installation d\u2019un aimant overband : transversale ou longitudinale ?"},"content":{"rendered":"\n<style>\n.cv-installation{--cv-accent:#334155;--cv-ink:#1f2937;--cv-muted:#4b5563;--cv-line:#e2e8f0;--cv-soft:#f8fafc;color:var(--cv-ink);font-family:inherit;font-size:17px;line-height:1.75;overflow-wrap:anywhere}\n.cv-installation *{box-sizing:border-box}\n.cv-installation .cv-section,.cv-installation .cv-intro,.cv-installation .cv-nav{display:block;margin:0 0 24px;padding:22px;border:1px solid var(--cv-line);border-radius:16px;background:#fff}\n.cv-installation .cv-section{border-top:4px solid var(--cv-accent);box-shadow:0 2px 7px #0f172a06}\n.cv-installation .cv-intro,.cv-installation .cv-nav,.cv-installation .faq{background:var(--cv-soft)}\n.cv-installation h2,.cv-installation h3{color:var(--cv-ink);line-height:1.3;scroll-margin-top:100px}\n.cv-installation h2{font-size:30px;margin:0 0 20px}\n.cv-installation h3{font-size:24px;margin:28px 0 14px}\n.cv-installation p{margin:0 0 16px}\n.cv-installation p:last-child{margin-bottom:0}\n.cv-installation ul,.cv-installation ol{padding-left:1.4em;margin:12px 0 20px}\n.cv-installation li{margin:8px 0}\n.cv-installation a{color:var(--cv-accent);text-decoration:underline;text-underline-offset:3px}\n.cv-installation a:hover{color:#0f172a}\n.cv-installation a:focus-visible,.cv-installation .cv-table:focus-visible{outline:3px solid #475569;outline-offset:4px}\n.cv-installation .cv-media{display:block;float:none;clear:both;margin:20px 0}\n.cv-installation .cv-media img{display:block;float:none;max-width:100%;width:100%;height:auto;margin-inline:auto;border-radius:10px}\n.cv-installation .cv-table{overflow-x:auto;margin:20px 0;-webkit-overflow-scrolling:touch}\n.cv-installation table{border-collapse:collapse;width:100%;min-width:620px;font-size:16px;line-height:1.6}\n.cv-installation th,.cv-installation td{text-align:left;vertical-align:top;border:1px solid var(--cv-line);padding:12px}\n.cv-installation th{background:var(--cv-accent);color:#fff}\n.cv-installation tbody tr:nth-child(even){background:var(--cv-soft)}\n.cv-installation .cv-button{display:inline-block;background:var(--cv-accent);color:#fff;border-radius:8px;padding:12px 18px;text-decoration:none;font-weight:700}\n.cv-installation .cv-button:hover{background:#0f172a;color:#fff}\n.cv-installation .faq h3{padding-top:20px;border-top:1px solid var(--cv-line)}\n@media(max-width:768px){\n.cv-installation{font-size:16px}\n.cv-installation .cv-section,.cv-installation .cv-intro,.cv-installation .cv-nav{padding:18px;margin-bottom:18px;border-radius:12px}\n.cv-installation .cv-section{border-top-width:3px}\n.cv-installation h2{font-size:24px}\n.cv-installation h3{font-size:20px}\n.cv-installation th,.cv-installation td{padding:10px}\n}\n<\/style>\n<article class=\"cv-installation\"><div class=\"cv-intro\"><p>For <strong>overband magnet installation, choose cross-belt when an existing conveyor has a clear side-discharge area. Compare in-line mounting when the head-pulley discharge is accessible and the material opens as it leaves the belt.<\/strong> The better layout must both lift the unwanted iron and deliver it into a separate collection area.<\/p><p>An overband magnet removes iron and steel pieces, often called tramp iron. On a self-cleaning unit, a moving belt carries captured metal away from the magnet. That belt needs room to run with the metal attached. A layout that picks up a bolt but drops it back into the product has not completed the job.<\/p><\/div><nav aria-label=\"Article contents\" class=\"cv-nav\"><p><strong>On this page<\/strong><\/p><ul><li><a href=\"#difference\">What is the difference between cross-belt and in-line installation?<\/a><\/li><li><a href=\"#choose-layout\">Which layout fits your conveyor?<\/a><\/li><li><a href=\"#installation-height\">How should you measure the installation height?<\/a><\/li><li><a href=\"#installation-space\">What space and conveyor changes must be planned?<\/a><\/li><li><a href=\"#install-start\">How do you install and start the overband magnet?<\/a><\/li><li><a href=\"#verify-performance\">How do you prove the installed layout works?<\/a><\/li><li><a href=\"#final-choice\">Final choice: match capture and discharge<\/a><\/li><li><a href=\"#faq\">Overband magnet installation FAQ<\/a><\/li><\/ul><\/nav><section class=\"cv-section\" id=\"difference\"><h2>What is the difference between cross-belt and in-line installation?<\/h2><p><strong>A cross-belt overband runs across the main conveyor and normally discharges iron to one side. An in-line overband runs along the conveyor direction, commonly above the head-pulley discharge.<\/strong> The head pulley is the pulley at the conveyor&#8217;s discharge end.<\/p><div aria-label=\"Comparison table\" class=\"cv-table\" role=\"region\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">Installation detail<\/th><th scope=\"col\">Cross-belt<\/th><th scope=\"col\">In-line<\/th><\/tr><\/thead><tbody>\n<tr><td>Cleaning-belt direction<\/td><td>Across the main material flow<\/td><td>Along the main material flow<\/td><\/tr>\n<tr><td>Common capture position<\/td><td>Above the loaded belt; also possible near the head pulley<\/td><td>Near the head-pulley discharge<\/td><\/tr>\n<tr><td>Iron collection<\/td><td>Beside the main conveyor<\/td><td>In a separate collection path at the discharge end<\/td><\/tr>\n<tr><td>Space to reserve<\/td><td>Width for the cleaning belt, iron drop and service access<\/td><td>Length around the discharge, chute and iron collection path<\/td><\/tr>\n<\/tbody><\/table><\/div><p>Two choices sit behind these names: <strong>where the iron becomes easiest to extract, and where the cleaning belt can carry it.<\/strong> A transverse cleaning belt can also work at a head-end position. It does not have to sit halfway along a loaded conveyor.<\/p><p>Permanent and electromagnetic describe the source of the magnetic field. Cross-belt and in-line describe the arrangement. Turning a separator through 90 degrees does not by itself increase its magnetic strength; it changes the target&#8217;s path, exposure and discharge route.<\/p><\/section><section class=\"cv-section\" id=\"choose-layout\"><h2>Which layout fits your conveyor?<\/h2><p><strong>Start with cross-belt for a retrofit with usable side space. Start with in-line when the discharge end offers a better lifting path and room to keep iron apart from the product.<\/strong> If the preferred position cannot provide a safe collection path, change the layout before selecting the magnet size.<\/p><h3>Existing conveyor with side-discharge space<\/h3>\n<figure class=\"cv-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-rcydc-cross-belt-installed-conveyor.webp\" alt=\"Suspended self-cleaning separator mounted above a conveyor belt\" width=\"752\" height=\"577\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/figure><p><strong>Cross-belt is usually the practical starting choice when you can add overhead support and collect iron beside the belt.<\/strong> It can avoid rebuilding a crowded transfer chute.<\/p><p>The trade-off is the material layer, or burden. Iron at the bottom must rise through the material above it. Compare normal and peak burden depth, not just an empty-conveyor measurement. If peak loads force the magnet too far away, first consider spreading or controlling the feed, then compare a different capture position or a magnet sized for the greater distance.<\/p><p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/overband-magnetic-separator\/\">permanent overband magnetic separators<\/a> cover this continuous iron-removal task. The <a href=\"https:\/\/www.corvelanmag.com\/products\/self-cleaning-cross-belt-permanent-magnet-separator\/\">self-cleaning cross-belt permanent magnet separator<\/a> is a relevant option when a permanent magnetic system can reach the target and side discharge is available.<\/p><h3>Accessible conveyor head with room for separate discharge<\/h3><p><strong>In-line is worth comparing first when iron is buried and the conveyor discharge can expose it to the magnet.<\/strong> As material leaves the belt, the bed opens and the iron can become easier to extract. The benefit comes from the material&#8217;s condition and path.<\/p><p>Allow for the product&#8217;s flight path, the separator&#8217;s cleaning belt and the iron chute together. A splitter\u2014a divider between the product and iron paths\u2014can keep the two streams apart. Its position must suit the material trajectory over the operating speed and feed range.<\/p><p>Suppose you are designing a new quarry transfer before a crusher. If the discharge area is accessible and both streams can be collected separately, compare in-line before fixing the chute and support steel. If the transfer is already enclosed and cannot be changed, a cross-belt position farther upstream may be the workable choice.<\/p><h3>Head-end capture with side discharge<\/h3><p><strong>A cross-belt near the head pulley can combine an opening material stream with side collection, where the machine and transfer layout allow it.<\/strong> <a href=\"https:\/\/dingsmagnets.com\/wp-content\/uploads\/2025\/01\/Overhead-Magnet-Selection-Guide-and-General-OH-RFQ-1_25.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Dings&#8217; overhead-magnet selection guide<\/a> distinguishes this from both cross-belt over the loaded belt and in-line mounting.<\/p><p>Draw all three options when the head is available but an in-line iron chute would clash with the receiving conveyor. Keep the product and iron paths separate through their full drop. Material opening at discharge can expose free iron; it does not detach steel still bonded into rubber, plastic or another solid piece.<\/p><\/section><section class=\"cv-section\" id=\"installation-height\"><h2>How should you measure the installation height?<\/h2><p><strong>Use the selected machine&#8217;s drawing to identify the height reference, then measure from the magnetic face to the hardest target position. Keep enough mechanical clearance for peak material, large pieces and the cleaning belt carrying captured iron.<\/strong> The gap above the material and the suspension height above the conveyor are different measurements.<\/p><h3>Separate the face-to-material gap, burial depth and suspension height<\/h3><p>On a simple horizontal, flat-belt section, use three measurements:<\/p><ul>\n<li><strong>Face-to-material gap:<\/strong> from the magnetic face to the top of the material, measured along the same vertical line.<\/li>\n<li><strong>Burial depth:<\/strong> from that material surface down to the target iron.<\/li>\n<li><strong>Distance to the target:<\/strong> face-to-material gap plus burial depth along that line.<\/li>\n<\/ul><p>For example, suppose the magnetic face is 110 mm above a 190 mm material bed, and the target sits at the bottom. The distance to that target is <strong>110 + 190 = 300 mm<\/strong>. Raising the separator by 80 mm makes it <strong>380 mm<\/strong>. The extra height helps physical clearance but makes the magnetic lifting task harder.<\/p><p>Now keep the magnetic face fixed 300 mm above the main belt and increase the material bed to 240 mm. The gap above the material becomes 60 mm; the bottom target is still 300 mm from the face. The deeper bed also puts more material in the lifting path. Do not add the full bed depth again to a dimension already measured from the magnet face to the conveyor belt.<\/p><p>Some drawings use the magnetic block face; others show the outside of the cleaning belt. Include the construction offset when changing between those references. If the cleaning belt lies below the magnetic face, the free running clearance is smaller than the face-to-material gap by that offset. For troughed belts, inclined conveyors and airborne discharge, use the actual section and target path rather than applying the flat-belt addition blindly.<\/p><h3>Plan for peaks without losing the working position<\/h3><p><strong>If the magnet must be raised repeatedly to pass material surges, solve the peak-load clearance and magnetic reach together.<\/strong> Leaving it higher after a surge changes the condition for which it was selected.<\/p><p>Record the approved position from fixed reference points and mark the adjustment hardware. After authorized adjustments, return to that position and repeat the relevant removal checks. Where the required clearance exceeds the unit&#8217;s working capability, reduce the surge, improve feed distribution or compare another separator position or size.<\/p><p>There is no single clearance in millimeters that fits every overband magnet. Lump size, captured-iron shape, cleats and the selected magnetic circuit all affect the usable setting.<\/p><\/section><section class=\"cv-section\" id=\"installation-space\"><h2>What space and conveyor changes must be planned?<\/h2><p><strong>Reserve space for magnetic capture, iron transport, the final drop and maintenance before fixing the support frame. Identify nearby steel within the selected machine&#8217;s magnetic working area.<\/strong> Fitting the outer frame above the conveyor is only one part of the installation.<\/p><h3>Nearby steel and the head pulley<\/h3><p>Steel idlers, chute walls, skirt supports and beams can divert magnetic flux and become magnetized. Mark them on the conveyor section drawing. The selected layout may need non-magnetic replacements or relocated steelwork within a defined area.<\/p><p>A non-magnetic head pulley and a magnetic head pulley serve different purposes. <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/IOMs\/Magnetic-Separation\/SM-307-Eriez-Model-CP-Suspend-Permanent-Magnet-IOM.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s Model CP installation manual<\/a> specifies a non-magnetic head pulley for its in-line arrangement. Do not add a magnetic pulley beneath a suspended magnet on the assumption that two magnets must work better together; their fields and collection paths need to be designed together.<\/p><h3>Magnetic coverage and the iron drop<\/h3><p>Use the <strong>magnetic block and its working coverage<\/strong>, not just the overall frame width, to review the full material stream. A wider frame can contain a smaller magnetic block. Also trace how far iron stays held as the cleaning belt carries it toward the outlet.<\/p><p><a href=\"https:\/\/buntingmagnetics.com\/blog\/three-things-to-consider-when-installing-crossbelt-magnets\" rel=\"nofollow noopener\" target=\"_blank\">Bunting&#8217;s installation guidance<\/a> describes two different failures: poor pickup on the far side after lateral repositioning, and iron falling back onto the main conveyor when the magnetic coverage or discharge reach is inadequate. Moving an undersized unit sideways to reach a bin can exchange one failure for the other.<\/p><p>Follow the selected magnet&#8217;s position drawing. Pole arrangements differ, so the frame centerline alone is not a universal mounting rule. Review capture across the loaded width and retention to the discharge side as separate requirements.<\/p><p>Keep the iron chute clear of the product path, walkway and receiving equipment. Allow for the largest expected steel piece, including a long bar carried sideways. Position any splitter so it separates the actual streams without obstructing normal product flow. The collection bin must remain accessible for emptying before accumulated iron blocks the outlet.<\/p><h3>Support, adjustment and service access<\/h3><p>Use the selected unit&#8217;s mass, suspension points and installation loads for the support design. Qualified personnel should design the steelwork and lifting arrangement. Leave adjustment access so height and angle can be set without improvised wedges or loaded lifting equipment left in place.<\/p><p>Provide access to the drive, bearings and belt-adjustment points, plus room to remove or replace the cleaning belt. Include guards and lifting access in the layout. A machine that fits only with a guard removed needs a revised layout.<\/p><\/section><section class=\"cv-section\" id=\"install-start\"><h2>How do you install and start the overband magnet?<\/h2><p><strong>Secure the support and collection path first, set the specified working position, prove the protective controls, then run empty before introducing material. Stop and isolate the equipment before mechanical adjustments.<\/strong> Keep personnel away from suspended loads, moving belts and the iron drop area.<\/p><p>A permanent magnet remains magnetic when its belt motor is off. Control loose steel tools and use the equipment&#8217;s magnetic-field access restrictions, including those for people with affected medical implants. Isolation of electrical power does not remove this magnetic hazard.<\/p><ol>\n<li><strong>Prepare the stopped line.<\/strong> Apply the site&#8217;s energy-isolation procedure to the conveyor, separator drive and connected equipment. Secure stored energy and verify isolation. Clear the lifting and discharge areas.<\/li>\n<li><strong>Lift using the approved points and method.<\/strong> Check the unit for transport damage and frame distortion. Install the specified suspension hardware on the completed support; do not lift from the cleaning belt or drive parts.<\/li>\n<li><strong>Set position from the drawing.<\/strong> Measure height from its stated datum. Set the required angle and lateral position, then secure the adjustments. Make the nearby conveyor changes and fit the separate iron collection path.<\/li>\n<li><strong>Complete guards and controls.<\/strong> Qualified electrical personnel should connect the drive and any magnet power or cooling system supplied. Establish the specified stop response, overload protection and conveyor interfaces. Test emergency stops and applicable guard interlocks before the first run.<\/li>\n<li><strong>Jog the cleaning belt from a safe position.<\/strong> Verify the marked travel direction and tracking. Stop if it wanders, rubs or contacts a guard. Isolate before adjustment; use the unit&#8217;s tension and tracking procedure rather than tightening both sides until the belt looks taut.<\/li>\n<li><strong>Run empty, then with representative material.<\/strong> Observe vibration, rubbing and clearance from outside the guarded area. Introduce feed within the planned operating range, then complete the removal trials below. Secure and record the final settings after successful trials.<\/li>\n<\/ol><p>For an electromagnet, the control sequence must also address loss of magnetic power and the effect on captured iron and downstream protection. Include that response in the commissioning procedure before production starts.<\/p><\/section><section class=\"cv-section\" id=\"verify-performance\"><h2>How do you prove the installed layout works?<\/h2><p><strong>Run controlled trials at the agreed material depth, belt speed and working height, using the iron pieces and positions that matter to your process. Count successful delivery into the iron collection area, not just pickup.<\/strong> Set the test conditions and acceptance rule before testing.<\/p><p>Use a safe trial arrangement that prevents missed samples from reaching a crusher or other vulnerable equipment. Place samples only while the relevant equipment is stopped and isolated, or through an approved remote feeding method. Account for every test piece; never reach into the running conveyor or separator.<\/p><p>Record these items together:<\/p><ul>\n<li>Material, particle size, moisture and feed rate, including the peak condition the installation must handle.<\/li>\n<li>Main-belt speed, material depth, magnetic-face reference and separator position.<\/li>\n<li>Test-piece material, dimensions, shape and mass where relevant. Include the small cleanup target as well as damaging larger iron if both matter.<\/li>\n<li>Position across the loaded width and depth within the bed. Test the difficult edge and buried positions, not only exposed iron at the center.<\/li>\n<li>Repeated passes under each agreed condition, pieces collected, pieces missed and any return to the product. Keep results separated by condition.<\/li>\n<li>Product carried into the iron stream, chute blockage, belt contact and tracking during the trials.<\/li>\n<\/ul><p>For example, suppose 12 identified pieces pass under one defined condition, 10 reach the collection bin and two remain in the product. The collected-piece result is <strong>10 \u00f7 12 \u00d7 100 = 83.3% for that trial<\/strong>. Locate the two failures by position and depth before deciding what to adjust. Do not average easy surface passes with difficult buried passes to hide a weak area.<\/p><h3>What should you change if the trial fails?<\/h3><p><strong>Use the failure pattern to separate poor pickup from poor discharge, then repeat the failed condition after adjustment.<\/strong> These observations narrow the investigation; they do not identify a cause on their own.<\/p><div aria-label=\"Comparison table\" class=\"cv-table\" role=\"region\" tabindex=\"0\"><table><thead><tr><th scope=\"col\">What you observe<\/th><th scope=\"col\">Evidence to collect<\/th><th scope=\"col\">Next action and recheck<\/th><\/tr><\/thead><tbody>\n<tr><td>Misses mainly on one side<\/td><td>Compare loaded width, magnetic-block position and nearby steel on both sides<\/td><td>Correct the layout against the machine drawing; retest both edges and center<\/td><\/tr>\n<tr><td>Iron lifts, then falls back<\/td><td>Observe the release point safely; inspect obstructions after isolation<\/td><td>Correct retention\/discharge reach, chute or splitter position; repeat through final collection<\/td><\/tr>\n<tr><td>Exposed iron passes, buried iron fails<\/td><td>Compare depth, target distance and feed condition at the same speed<\/td><td>Improve feed presentation or compare another position\/size; retest the deepest target<\/td><\/tr>\n<tr><td>Removal worsens after maintenance<\/td><td>Compare height and angle with the recorded settings; inspect tracking<\/td><td>Restore the intended setup and clear faults; rerun the earlier acceptance conditions<\/td><\/tr>\n<\/tbody><\/table><\/div><p>Keep the trial record with the final layout drawing and settings. Repeat the affected checks after relocation, a higher belt speed, a different burden or a change to the iron discharge path.<\/p><\/section><section class=\"cv-section\" id=\"final-choice\"><h2>Final choice: match capture and discharge<\/h2><p><strong>Choose cross-belt when the existing conveyor and side collection area provide a workable installation. Compare in-line at an accessible discharge end, especially when opening the material bed improves access to buried iron.<\/strong> A head-end cross-belt can also be worth comparing when side collection is preferable.<\/p><p>Successful overband magnet installation joins three things: enough magnetic reach at the difficult target, room for the machine to operate, and a separate path into the iron bin. Approve the layout through controlled removal trials across the operating conditions, then keep the successful settings recorded.<\/p><h3>Discuss your conveyor layout with Corvelan<\/h3><p>Use our contact form&#8217;s message field to send your material, target iron, belt width and speed, normal and peak material depth, and proposed side or head-end position. Tell us whether a drawing or site photo is available so we can arrange to review it. We use these details to compare the separator type and mounting arrangement.<\/p><p><a class=\"cv-button\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Request an overband layout review.<\/a><\/p><\/section><section class=\"cv-section faq\" id=\"faq\"><h2>Overband magnet installation FAQ<\/h2><h3>Can I move an existing overband magnet to a wider conveyor?<\/h3><p><strong>Only if its magnetic coverage, working distance and iron-discharge reach suit the wider loaded stream.<\/strong> Obtain the original model drawing and compare the new belt width, target position and collection point. If the far edge falls outside the working coverage, shifting the unit toward the bin can make pickup worse there. Reuse it only after the revised layout and removal trials meet the new requirement.<\/p><h3>Can I change the discharge side by reversing the cleaning-belt motor?<\/h3><p><strong>Do not assume motor reversal converts a left-discharge machine into a right-discharge machine.<\/strong> The belt travel, magnet position, drive, guards and chute must suit the intended direction. Request a revised arrangement for the selected unit, then prove tracking and full iron discharge. Reversing a motor alone can move iron toward an unsuitable release point.<\/p><h3>Can a cross-belt magnet be mounted above an inclined conveyor?<\/h3><p><strong>Yes, when the selected unit is designed for that conveyor angle and the captured iron remains controlled through discharge.<\/strong> Supply the belt inclination and a side view showing material depth and nearby steel. Use that unit&#8217;s angle, support and belt arrangement; a maximum angle in another manufacturer&#8217;s manual is specific to its equipment.<\/p><h3>Could a manual-clean suspended electromagnet replace the self-cleaning overband?<\/h3><p><strong>It can be suitable when iron is occasional and controlled cleaning stops are acceptable. Frequent iron favors a self-cleaning arrangement.<\/strong> Our <a href=\"https:\/\/www.corvelanmag.com\/products\/suspended-electromagnetic-separator\/\">RCDB suspended electromagnetic separator<\/a> is a manual-clean option. Changing to it also changes how accumulated iron is removed and collected. Plan that cleaning access and sequence before choosing it as a replacement.<\/p><h3>Should I raise the magnet when wetter material starts touching the cleaning belt?<\/h3><p><strong>Stop the contact, then resolve the changed material profile and magnetic distance together. Raising the unit alone may reduce iron pickup.<\/strong> Measure the new peak bed and inspect buildup, feed surges and large lumps after isolation. Restore a stable feed profile or select a working position and magnet that handle the changed condition, then repeat the buried-target and discharge trials with that material.<\/p><\/section><\/article>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I move an existing overband magnet to a wider conveyor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Only if its magnetic coverage, working distance and iron-discharge reach suit the wider loaded stream. Obtain the original model drawing and compare the new belt width, target position and collection point. If the far edge falls outside the working coverage, shifting the unit toward the bin can make pickup worse there. Reuse it only after the revised layout and removal trials meet the new requirement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I change the discharge side by reversing the cleaning-belt motor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Do not assume motor reversal converts a left-discharge machine into a right-discharge machine. The belt travel, magnet position, drive, guards and chute must suit the intended direction. Request a revised arrangement for the selected unit, then prove tracking and full iron discharge. Reversing a motor alone can move iron toward an unsuitable release point.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a cross-belt magnet be mounted above an inclined conveyor?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, when the selected unit is designed for that conveyor angle and the captured iron remains controlled through discharge. Supply the belt inclination and a side view showing material depth and nearby steel. Use that unit's angle, support and belt arrangement; a maximum angle in another manufacturer's manual is specific to its equipment.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Could a manual-clean suspended electromagnet replace the self-cleaning overband?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It can be suitable when iron is occasional and controlled cleaning stops are acceptable. Frequent iron favors a self-cleaning arrangement. Our RCDB suspended electromagnetic separator is a manual-clean option. Changing to it also changes how accumulated iron is removed and collected. Plan that cleaning access and sequence before choosing it as a replacement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should I raise the magnet when wetter material starts touching the cleaning belt?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Stop the contact, then resolve the changed material profile and magnetic distance together. Raising the unit alone may reduce iron pickup. Measure the new peak bed and inspect buildup, feed surges and large lumps after isolation. Restore a stable feed profile or select a working position and magnet that handle the changed condition, then repeat the buried-target and discharge trials with that material.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>For overband magnet installation, choose cross-belt when an existing conveyor has a clear side-discharge area. Compare in-line mounting when the head-pulley discharge is accessible and the material opens as it leaves the belt. The better layout must both lift the unwanted iron and deliver it into a separate collection area. An overband magnet removes iron [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4320,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5523","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/comments?post=5523"}],"version-history":[{"count":1,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5523\/revisions"}],"predecessor-version":[{"id":5606,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5523\/revisions\/5606"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media\/4320"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media?parent=5523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/categories?post=5523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/tags?post=5523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}