{"id":5525,"date":"2026-11-05T20:28:34","date_gmt":"2026-11-05T12:28:34","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5525"},"modified":"2026-10-30T13:02:47","modified_gmt":"2026-10-30T05:02:47","slug":"wet-drum-magnetic-separator-recovery","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/fr\/wet-drum-magnetic-separator-recovery\/","title":{"rendered":"R\u00e9cup\u00e9ration et teneur du concentr\u00e9 avec un s\u00e9parateur \u00e0 tambour par voie humide : quel r\u00e9glage effectuer en premier ?"},"content":{"rendered":"\n<style>\n.cv-wet-guide{display:block;float:none;columns:auto;box-sizing:border-box;font-family:inherit;font-size:17px;line-height:1.75;color:#243239;overflow-wrap:anywhere}\n.cv-wet-guide .cv-intro,.cv-wet-guide .cv-section,.cv-wet-guide .cv-toc{display:block;float:none;columns:auto;box-sizing:border-box;padding:22px;margin:0 0 24px;border:1px solid #dce1e4;border-radius:16px;background:#fff}\n.cv-wet-guide .cv-section{border-top:4px solid #4b565e;scroll-margin-top:100px;box-shadow:0 2px 8px #00000006}\n.cv-wet-guide .cv-intro,.cv-wet-guide .cv-toc{background:#f3f5f6}\n.cv-wet-guide h2{font-size:30px;line-height:1.3;color:#243239;margin:0 0 18px}\n.cv-wet-guide h3{font-size:24px;line-height:1.3;color:#243239;margin:26px 0 12px}\n.cv-wet-guide p{margin:0 0 16px}\n.cv-wet-guide strong{font-weight:700}\n.cv-wet-guide a{color:#263f4b;text-decoration:underline;text-underline-offset:3px}\n.cv-wet-guide a:focus-visible,.cv-wet-guide summary:focus-visible,.cv-wet-guide .cv-table-scroll:focus-visible{outline:3px solid #4b565e;outline-offset:4px}\n.cv-wet-guide ul,.cv-wet-guide ol{margin:0 0 18px;padding-inline-start:25px}\n.cv-wet-guide li{margin:0 0 9px}\n.cv-wet-guide .cv-media{display:block;float:none;clear:both;margin:0 0 20px}\n.cv-wet-guide .cv-media img{display:block;float:none;width:100%;max-width:100%;height:auto;margin:0}\n.cv-wet-guide .cv-table-scroll{display:block;max-width:100%;overflow-x:auto;margin:20px 0}\n.cv-wet-guide table{width:100%;min-width:590px;border-collapse:collapse;font:inherit}\n.cv-wet-guide th,.cv-wet-guide td{padding:12px 14px;border:1px solid #dce1e4;text-align:left;vertical-align:top}\n.cv-wet-guide th{background:#eef1f3;color:#243239;font-weight:700}\n.cv-wet-guide tbody tr:nth-child(even){background:#f8f9fa}\n.cv-wet-guide .cv-toc summary{cursor:pointer;font-weight:700;padding:2px 0}\n.cv-wet-guide .cv-toc ol{margin-top:14px;margin-bottom:0}\n.cv-wet-guide .cv-faq-item{border-top:1px solid #dce1e4;padding:16px 0}\n.cv-wet-guide .cv-faq-item summary{cursor:pointer;font-weight:700;line-height:1.5;list-style:none;padding-right:24px;position:relative}\n.cv-wet-guide .cv-faq-item summary::-webkit-details-marker{display:none}\n.cv-wet-guide .cv-faq-item summary::after{content:'+';position:absolute;right:0;top:0}\n.cv-wet-guide .cv-faq-item[open] summary::after{content:'\u2212'}\n.cv-wet-guide .cv-faq-answer{display:block;padding-top:14px}\n.cv-wet-guide .cv-section>:last-child,.cv-wet-guide .cv-intro>:last-child,.cv-wet-guide .cv-faq-answer>:last-child{margin-bottom:0}\n@media(max-width:768px){.cv-wet-guide{font-size:16px}.cv-wet-guide .cv-intro,.cv-wet-guide .cv-section,.cv-wet-guide .cv-toc{padding:18px;margin-bottom:18px;border-radius:12px}.cv-wet-guide .cv-section{border-top-width:3px}.cv-wet-guide h2{font-size:24px}.cv-wet-guide h3{font-size:20px}.cv-wet-guide th,.cv-wet-guide td{padding:10px 12px}}\n<\/style>\n<article class=\"cv-wet-guide\">\n<div class=\"cv-intro\"><p>For better wet drum magnetic separator recovery, <strong>stabilize the feed, slurry level and discharge before changing drum speed or the magnetic system.<\/strong> If recovery is low, find out which magnetic particles are leaving in the tailings. If recovery is good but concentrate grade is low, separate poor liberation from unwanted gangue carried into the concentrate. Those problems need different adjustments.<\/p>\n<p>This guide focuses on magnetite ore in wet low-intensity magnetic separation. Recovery of magnetite or ferrosilicon from dense-media circuits has a different product target and should be assessed separately.<\/p><\/div>\n<nav class=\"cv-toc\" aria-label=\"Article contents\"><details><summary>On this page<\/summary><ol><li><a href=\"#quick-summary\">Quick Summary<\/a><\/li><li><a href=\"#measure-results\">What should you measure before changing settings?<\/a><\/li><li><a href=\"#recovery-falls\">If recovery falls, what should you adjust first?<\/a><\/li><li><a href=\"#grade-is-low\">If recovery is high but grade is low, what comes first?<\/a><\/li><li><a href=\"#drum-settings\">Which drum settings should you change after the feed checks?<\/a><\/li><li><a href=\"#separation-stages\">When do you need a cleaner, scavenger or regrind stage?<\/a><\/li><li><a href=\"#run-a-trial\">How do you run a trial and decide whether it worked?<\/a><\/li><li><a href=\"#what-to-adjust\">What should you adjust first on your line?<\/a><\/li><li><a href=\"#faq\">Wet drum recovery and concentrate grade FAQ<\/a><\/li><\/ol><\/details><\/nav>\n<section class=\"cv-section\" id=\"quick-summary\"><h2>Quick Summary<\/h2>\n\n<p><strong>Start with a measured baseline, then change the condition linked to the symptom.<\/strong> A stronger magnetic field is useful only when magnetic capture is the actual limit.<\/p>\n<div class=\"cv-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\"><table><thead><tr><th scope=\"col\">What has changed?<\/th><th scope=\"col\">First investigation<\/th><th scope=\"col\">First adjustment to test<\/th><\/tr><\/thead><tbody><tr><td>Recovery falls as throughput rises<\/td><td>Slurry volume, dry solids rate, magnetic loading and feed distribution<\/td><td>Restore even feed; reduce the load on the affected drum and compare results<\/td><\/tr><tr><td>Recovery is good, but dry concentrate grade is low<\/td><td>Locked waste mineral versus free waste mineral carried with magnetics<\/td><td>Improve liberation if particles are locked; improve cleaning and flow if gangue is free<\/td><\/tr><tr><td>Grade and recovery both become unstable<\/td><td>Feed changes, tank level, blocked outlets and concentrate discharge<\/td><td>Restore stable flow and clear discharge before tuning separation settings<\/td><\/tr><tr><td>Fine magnetic particles remain in tailings under stable, moderate loading<\/td><td>Particle-size response and the magnetic system at the working gap<\/td><td>Test a suitable magnetic circuit or recovery stage with the actual fine fraction<\/td><\/tr><\/tbody><\/table><\/div>\n<p>Read grade and recovery together with <strong>dry tonnes per hour<\/strong>. A setting that produces a higher assay by rejecting more valuable mineral may miss the plant&#8217;s recovery target.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"measure-results\"><h2>What should you measure before changing settings?<\/h2>\n<figure class=\"cv-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-wet-drum-magnetic-separator-real-product-20260923.webp\" alt=\"Wet drum separator units with stainless drum shells and motor drives\" width=\"800\" height=\"600\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/figure>\n<p><strong>Measure the dry feed, concentrate and tailings flows, and assay the same target component in all three.<\/strong> Also record particle size, feed solids concentration, slurry flow, drum speed, tank level and the stage being tested. Without these inputs, a higher concentrate assay can hide a larger mineral loss.<\/p>\n<p>Take representative samples over corresponding operating periods after the circuit has settled. Allow for travel time between sampling points. Include any spill, bypass or separate reject stream in the balance rather than treating it as unmeasured loss.<\/p>\n<h3>Recovery, concentrate grade and mass yield<\/h3>\n<p><strong>Grade tells you how rich the concentrate is; recovery tells you how much of the feed&#8217;s target component reaches it.<\/strong> Mass yield is the share of total dry feed mass sent to concentrate.<\/p>\n<p>Let F and C be dry feed and concentrate rates in t\/h. Let f and c be the feed and concentrate assays, both expressed as the same weight percentage:<\/p>\n<ul><li>Concentrate grade = c.<\/li><li>Mass yield (%) = 100 \u00d7 C \u00f7 F.<\/li><li>Component recovery (%) = 100 \u00d7 (C \u00d7 c) \u00f7 (F \u00d7 f).<\/li><\/ul>\n<p>Use total Fe assays throughout to calculate total Fe recovery. Use a defined magnetite or magnetic-iron measurement throughout to calculate that component&#8217;s recovery. <strong>Do not mix total Fe in the feed with magnetite content in the product.<\/strong> Wet slurry mass also cannot replace dry solids mass in these equations.<\/p>\n<p>The <a href=\"https:\/\/pressbooks.bccampus.ca\/hydrometallurgy\/chapter\/6-particle-selection-making-concentrates\/\" rel=\"nofollow noopener\" target=\"_blank\">grade and recovery definitions in this mineral-processing teaching chapter<\/a> use this component-mass approach. A feed-to-product concentration change alone does not give recovery.<\/p>\n<h3>A grade\u2013recovery example with a closed mass balance<\/h3>\n<p>Suppose a steady feed contains <strong>100 dry t\/h at 30% total Fe<\/strong>. Two trial settings produce these results:<\/p>\n<div class=\"cv-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\"><table><thead><tr><th scope=\"col\">Result<\/th><th scope=\"col\">Trial A<\/th><th scope=\"col\">Trial B<\/th><\/tr><\/thead><tbody><tr><td>Dry concentrate<\/td><td>45 t\/h<\/td><td>42 t\/h<\/td><\/tr><tr><td>Concentrate grade, total Fe<\/td><td>62%<\/td><td>65%<\/td><\/tr><tr><td>Fe in concentrate<\/td><td>27.9 t\/h<\/td><td>27.3 t\/h<\/td><\/tr><tr><td>Total Fe recovery<\/td><td>93%<\/td><td>91%<\/td><\/tr><tr><td>Mass yield<\/td><td>45%<\/td><td>42%<\/td><\/tr><\/tbody><\/table><\/div>\n<p>For Trial A, Fe recovery is 100 \u00d7 (45 \u00d7 62) \u00f7 (100 \u00d7 30) = <strong>93%<\/strong>. Trial B gives 100 \u00d7 (42 \u00d7 65) \u00f7 (100 \u00d7 30) = <strong>91%<\/strong>. The richer product in B carries <strong>0.6 t\/h less Fe<\/strong>, so it is an improvement in grade with a recovery cost.<\/p>\n<p>For a two-product circuit with no accumulation or other outlets, dry solids must balance as F = C + T. The target component must balance as F \u00d7 f = C \u00d7 c + T \u00d7 t, where T and t are tailings dry flow and assay.<\/p>\n<p>In A, tailings are 55 dry t\/h and contain 30 \u2212 27.9 = 2.1 t\/h Fe. Their calculated grade is <strong>3.82% total Fe<\/strong>. In B, 58 dry t\/h carry 2.7 t\/h Fe, or <strong>4.66% total Fe<\/strong>. These tailings assays are calculated from the example inputs; measured tailings assays provide a separate balance check in a plant trial.<\/p>\n<p>If measured flows and assays do not close within the sampling and laboratory uncertainty agreed for the trial, resolve that mismatch before selecting a setting. Check timing, moisture correction, omitted streams and changing tank inventory first.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"recovery-falls\"><h2>If recovery falls, what should you adjust first?<\/h2>\n<p><strong>First identify the lost mineral, then test whether the drum is being overloaded or fed unevenly.<\/strong> If the loss appears only during surges, correct the feed and flow problem before changing the magnetic system.<\/p>\n<h3>Separate magnetic losses from other iron in tailings<\/h3>\n<p><strong>A high tailings total-Fe assay calls for mineral identification before a magnetic adjustment.<\/strong> The iron may be in liberated magnetite, magnetite locked to gangue, or a mineral that responds too weakly for the existing low-intensity drum.<\/p>\n<p>Ask the laboratory to examine representative feed and tailings by size fraction. Pair total Fe assays with a defined magnetic separation test and mineralogical examination where needed. This shows whether the lost Fe is in a recoverable magnetic fraction and whether coarse or fine particles dominate the loss.<\/p>\n<p>If the tailings contain substantial liberated magnetite, investigate capture, loading and transport. If magnetite is locked in composite particles, review liberation and classification. If most of the remaining Fe belongs to weakly magnetic minerals, test a process suited to those minerals rather than repeatedly tightening the same wet drum setting.<\/p>\n<p>Keep laboratory test conditions in the record. A Davis Tube result depends on the test procedure and sample preparation; use it to characterize the feed or loss, not as an automatic prediction of production-drum performance.<\/p>\n<h3>Test loading, distribution and tank level<\/h3>\n<p><strong>Use a controlled reduction in feed to test a suspected capacity limit, while keeping mineral composition and size as similar as practical.<\/strong> Record slurry m\u00b3\/h, dry solids t\/h and the magnetic fraction separately. Each describes a different load.<\/p>\n<p>A drum may receive an acceptable dry tonnage but too much water. It may also receive the usual total solids rate with a much larger magnetic fraction. In that case, the amount it must carry to the concentrate discharge rises even though the plant&#8217;s tonnage display barely changes.<\/p>\n<p>Compare the normal and reduced-load periods. If magnetic losses fall at the lower load, examine the feed splitter, useful drum width and both hydraulic and magnetic loading. This result supports a loading investigation; it does not yet distinguish which of those loads caused the loss. Use the recorded flow and composition to separate them.<\/p>\n<p>Observe feed delivery across the width from a safe operating position. A blocked distributor can overload one strip of the drum while leaving the rest underused. Restore the intended distribution before deciding that more drum area is needed. STEINERT&#8217;s <a href=\"https:\/\/steinertglobal.com\/us\/sorting-systems\/magnetic-separation\/wet-drum-magnetic-separators\/steinert-wds\/\" rel=\"nofollow noopener\" target=\"_blank\">WDS technical description<\/a> also emphasizes full-width feed and discharge.<\/p>\n<p>Watch the tank level during both steady operation and surges. Compare it with the machine&#8217;s operating-level mark or drawing. A level fault, restricted outlet or backed-up concentrate launder can disrupt separation. Clear a physical blockage only after stopping and isolating the equipment and its feed.<\/p>\n<p>When losses remain high under stable, evenly distributed feed, use the size-by-size results to choose the next test. Fine liberated magnetite losses point toward a different capture requirement from coarse, poorly liberated particles. That is the point to investigate the working magnetic field, gradient and tank arrangement.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"grade-is-low\"><h2>If recovery is high but grade is low, what comes first?<\/h2>\n<p><strong>Find out whether the waste mineral is locked to magnetite or is being carried into the concentrate as free gangue.<\/strong> Locked particles call for better liberation. Free gangue calls for better separation and cleaning conditions.<\/p>\n<h3>Distinguish locked gangue from entrained gangue<\/h3>\n<p><strong>Use particle examination to choose between a liberation test and a cleaning test.<\/strong> Gangue is the unwanted mineral, such as silica. Liberation means freeing the magnetite from it; entrainment means carrying unwanted particles into the product with slurry or captured material.<\/p>\n<p>A polished-section or automated mineralogy examination can show whether silica remains attached to magnetic particles. Compare this evidence with particle-size assays and the grinding\/classification record. If the low-grade magnetic product contains many composites, test regrinding the relevant stream and then separating it again. Adding a cleaner without freeing the locked gangue may simply repeat the same separation.<\/p>\n<p>When gangue is already free, investigate the routes by which it reaches the product. Look for excess slurry crossing the concentrate lip, thick magnetic layers trapping fine waste, and poor concentrate drainage. Compare a controlled cleaning or dilution trial with the baseline while measuring both product grade and magnetic loss.<\/p>\n<p>The distinction matters because increasing capture can also retain more magnetic composites. A higher Gauss reading does not tell you whether the recovered particles contain less silica.<\/p>\n<h3>Dilute only when the added water can pass through the circuit<\/h3>\n<p><strong>Dilution is worth testing when concentrated slurry is carrying free gangue into the product and the separator has enough hydraulic capacity.<\/strong> Do the water balance first. Reducing solids percentage at the same dry feed rate increases the water load.<\/p>\n<p>Suppose the feed contains <strong>30 dry t\/h<\/strong>, and a trial reduces solids concentration from <strong>30% to 20% by mass<\/strong>:<\/p>\n<ul><li>At 30% solids: total slurry mass = 30 \u00f7 0.30 = 100 t\/h; water = <strong>70 t\/h<\/strong>.<\/li><li>At 20% solids: total slurry mass = 30 \u00f7 0.20 = 150 t\/h; water = <strong>120 t\/h<\/strong>.<\/li><li>Added water = <strong>50 t\/h<\/strong>, approximately <strong>50 m\u00b3\/h<\/strong> for water with density 1 t\/m\u00b3.<\/li><\/ul>\n<p>That added flow must pass through the tank and downstream equipment. If the circuit is already near its hydraulic limit, first test a lower dry feed rate or provide more capacity. Simply opening the water valve could exchange a grade problem for a recovery problem.<\/p>\n<p>Eriez&#8217;s <a href=\"https:\/\/www.eriez.com\/Documents\/Literature\/Brochures\/Products\/Magnetic-Separation\/MMPB-470-Eriez-Wet-Drum-Separator.pdf\" rel=\"nofollow noopener\" target=\"_blank\">wet drum operating description, pages 2\u20133<\/a> connects slurry flow, solids concentration and magnetic loading with separation. Use those variables together when setting the trial. Keep the feed dilution water and concentrate-discharge water as separate entries in the record; changing one does not reproduce the effect of changing the other.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"drum-settings\"><h2>Which drum settings should you change after the feed checks?<\/h2>\n<p><strong>Restore the machine&#8217;s intended operating geometry and reliable concentrate discharge, then test adjustable settings one at a time.<\/strong> Keep a record of the starting position so an unsuccessful change can be reversed.<\/p>\n<p>Stop and isolate the drum, drive and connected feed before measuring clearances, moving the magnetic assembly or working near the discharge. Strong magnetic attraction remains after the drive is switched off. Use safe access and suitable non-magnetic measuring tools; do not reach into running equipment.<\/p>\n<div class=\"cv-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\"><table><thead><tr><th scope=\"col\">Setting<\/th><th scope=\"col\">Evidence to look for<\/th><th scope=\"col\">Adjustment approach<\/th><\/tr><\/thead><tbody><tr><td>Drum-to-tank clearance<\/td><td>Wear, buildup or a position that differs from the machine drawing<\/td><td>Restore the specified geometry first; trial another permitted clearance only with flow and recovery measurements<\/td><\/tr><tr><td>Magnet assembly position<\/td><td>Product releases before the lip or carries past the intended release point<\/td><td>Restore the intended pickup and release positions relative to the tank and concentrate lip<\/td><\/tr><tr><td>Concentrate lip and discharge<\/td><td>Product builds up, returns to the tank, or enters a backed-up launder<\/td><td>Restore a clear product path and the designed lip position<\/td><\/tr><tr><td>Drum speed, where adjustable<\/td><td>Capture is stable but magnetic-product transport remains limiting<\/td><td>Compare permitted speeds under matched feed, recording grade, recovery and dry product rate<\/td><\/tr><tr><td>Discharge spray, where fitted<\/td><td>Blocked nozzles, uneven coverage or product remaining at the lip<\/td><td>Restore the intended spray coverage and direction; record the added water<\/td><\/tr><\/tbody><\/table><\/div>\n<p><strong>A smaller drum-to-tank gap is not a one-way recovery control.<\/strong> It places particles closer to the magnetic system, but it also narrows the slurry passage. At unchanged flow, local velocity can rise and work against capture. Judge both effects in the trial.<\/p>\n<p>M. Dworzanowski&#8217;s <a href=\"https:\/\/scielo.org.za\/pdf\/jsaimm\/v110n11\/04.pdf\" rel=\"nofollow noopener\" target=\"_blank\">wet drum optimization paper, pages 650\u2013652<\/a> discusses clearance, liquid level, magnetic position and product removal together. Use the drawing and adjustment limits for the installed machine rather than transferring a clearance from another separator.<\/p>\n<p>Likewise, <strong>do not assume that slowing the drum always improves recovery<\/strong>. Speed affects transport as well as the time particles spend in the working zone. Metso&#8217;s <a href=\"https:\/\/www.metso.com\/globalassets\/portfolio\/brochure-wlims-en-4930.pdf\" rel=\"nofollow noopener\" target=\"_blank\">WLIMS technical brochure, pages 6\u20137<\/a> describes adjustable drum\/magnet positioning but notes that drum speed is seldom changed on its installations. For a fixed-speed drive, investigate the intended operating arrangement before planning a drive modification.<\/p>\n<p>Consider a magnetic-system change when the feed and hydraulics are stable but the measured target fraction still escapes. Compare field strength and gradient at the working distance, supported by a material test. A single surface reading cannot select the best magnetic circuit for fine-particle recovery.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"separation-stages\"><h2>When do you need a cleaner, scavenger or regrind stage?<\/h2>\n<p><strong>Add a cleaner when recoverable concentrate needs upgrading, a scavenger when recoverable magnetics remain in tailings, and regrinding when locked particles limit separation.<\/strong> Choose the stream and its remaining problem before choosing another drum.<\/p>\n<div class=\"cv-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Scrollable comparison table\"><table><thead><tr><th scope=\"col\">Next step<\/th><th scope=\"col\">Stream it treats<\/th><th scope=\"col\">Reason to consider it<\/th><\/tr><\/thead><tbody><tr><td>Cleaner<\/td><td>Rougher concentrate<\/td><td>Remove free gangue while retaining enough of the valuable magnetic component<\/td><\/tr><tr><td>Scavenger<\/td><td>A tailings stream<\/td><td>Recover a measurable magnetic fraction that would otherwise leave the circuit<\/td><\/tr><tr><td>Regrind followed by separation<\/td><td>A stream containing valuable locked particles<\/td><td>Free the valuable mineral so another separation can reject the attached gangue<\/td><\/tr><tr><td>Parallel drum capacity<\/td><td>A split of the incoming feed<\/td><td>Reduce load per machine when hydraulic, solids or magnetic transport capacity is limiting<\/td><\/tr><\/tbody><\/table><\/div>\n<p>A rougher is the first recovery stage. It can retain magnetic composites that need further treatment. A cleaner treats that recovered stream rather than asking the rougher to produce the final grade in one pass. Eriez&#8217;s <a href=\"https:\/\/www.eriez.com\/Products\/Magnetic-Separation\/Magnetic-Processing-Concentration\/Magnetic-Separation-Solutions-for-Wet-Minerals-Processing\/Wet-Drum-Separators\" rel=\"nofollow noopener\" target=\"_blank\">concentration-duty description<\/a> separates these duties and connects the number of stages with liberation.<\/p>\n<p>Before adding a scavenger, measure its proposed feed. A large tailings slurry flow with a small magnetic fraction presents a different task from the rougher feed. Test that stream directly. Do not size the second stage by copying the first drum or assume that it will achieve the same percentage recovery.<\/p>\n<p>Keep each stage&#8217;s denominator clear. Cleaner recovery is measured against the component entering the cleaner. Plant recovery is measured against fresh feed and final product. With recycle, draw a boundary around the circuit and count only streams crossing it; include all final reject outlets. Internal returns are not extra fresh feed or extra final production.<\/p>\n<p>Our <a href=\"https:\/\/www.corvelanmag.com\/products\/wet-drum-magnetic-separator\/\">wet drum magnetic separator page<\/a> explains the equipment and tank information needed for these duties. For the surrounding grinding, classification and separation stages, use our <a href=\"https:\/\/www.corvelanmag.com\/applications\/iron-ore-separation\/\">iron ore separation application page<\/a>. Keep the measured stage results with the flowsheet so a new machine addresses the remaining loss or grade problem.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"run-a-trial\"><h2>How do you run a trial and decide whether it worked?<\/h2>\n<p><strong>Change one intended variable, sample a stable operating period, and judge grade, component recovery and dry throughput together.<\/strong> Return to the baseline setting to see whether a feed change, rather than the adjustment, explains the result.<\/p>\n<ol><li><strong>Set the targets.<\/strong> State the required final concentrate assay, minimum component recovery and dry throughput. Identify whether the assay is total Fe, magnetic iron or another defined component. Record any impurity limit that controls product acceptance.<\/li><li><strong>Record a baseline.<\/strong> Use the flow meter or a suitable timed-flow measurement, representative moisture\/solids tests, size analysis and laboratory assays. Keep drum settings, water additions, tank level and concentrate discharge condition in the same log.<\/li><li><strong>Make one controlled change.<\/strong> For example, test feed distribution or a permitted speed change. If dilution is the intended variable, record its unavoidable effect on slurry volume. Do not describe that trial as unchanged hydraulic loading.<\/li><li><strong>Wait for stable conditions.<\/strong> Allow the affected tanks, pipes and any recycle to settle. Use the actual circuit residence and inventory behavior to set the waiting period; a fixed number of minutes does not fit every installation.<\/li><li><strong>Sample corresponding streams.<\/strong> Collect feed, concentrate and tailings over matched periods, allowing for transport delay. Use representative stream cuts or installed samplers rather than a convenient scoop from the top of a settled container. Convert flows to dry solids and use the same assay method.<\/li><li><strong>Close both balances.<\/strong> Compare dry solids entering and leaving, then the target component. Investigate discrepancies against the trial&#8217;s sampling and assay uncertainty. Repeat a doubtful result before attributing it to a setting.<\/li><li><strong>Repeat the baseline and compare acceptable results.<\/strong> Look for a change that persists under comparable feed. Record the selected setting, the feed conditions where it worked, and the trend that should trigger another investigation.<\/li><\/ol>\n<p>Return to the earlier A\/B example. Suppose the required product is at least <strong>64% total Fe<\/strong>, with at least <strong>90% total Fe recovery<\/strong> and <strong>40 dry t\/h of concentrate<\/strong>. Trial B meets all three example targets: 65%, 91% and 42 t\/h. Trial A misses the grade requirement despite its higher recovery.<\/p>\n<p>If the minimum recovery becomes <strong>93%<\/strong>, neither trial meets the combined requirements. A still misses grade; B misses recovery. The next action is to investigate better liberation, cleaning or recovery of a specific reject stream, rather than declaring either setting successful on one number alone.<\/p>\n<p>The trial log, laboratory results and reconciled mass balance are the basis for that decision. A higher Gauss reading or a darker-looking concentrate is not a replacement for those measurements.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"what-to-adjust\"><h2>What should you adjust first on your line?<\/h2>\n<p><strong>Start with stable feed and a dry-basis mass balance, then follow the symptom.<\/strong> For low wet drum magnetic separator recovery, identify the lost magnetic fraction and investigate loading, distribution, level and discharge. For high recovery with low grade, distinguish locked gangue from entrainment before choosing regrinding or cleaner operating conditions.<\/p>\n<p>Move to drum geometry, speed or magnetic-system changes when the evidence points there. Select the setting or circuit that meets the required grade, recovery and dry output together.<\/p>\n<p>If you need to compare a different wet drum or tank arrangement, <a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">send your separation requirement to Corvelan<\/a>. In the message, include the material, stage, normal and peak dry throughput, slurry flow and solids concentration. Add the current feed\/concentrate\/tailings results and your target when available. Start with those figures; the flowsheet and test records can then support the equipment discussion.<\/p>\n<\/section>\n<section class=\"cv-section faq\" id=\"faq\"><h2>Wet drum recovery and concentrate grade FAQ<\/h2>\n<details class=\"cv-faq-item\"><summary>Can I judge magnetite losses from the color of the tailings?<\/summary><div class=\"cv-faq-answer\"><p><strong>No. Color can prompt an investigation, but it does not quantify magnetite loss or recovery.<\/strong> Take representative samples and measure dry tailings flow plus the relevant magnetic component. Use mineral identification when total Fe and magnetic response tell different stories. A hand magnet is a screening aid, not a quantitative recovery test.<\/p><\/div><\/details>\n<details class=\"cv-faq-item\"><summary>Can two drums be compared at the same rpm?<\/summary><div class=\"cv-faq-answer\"><p><strong>Only when diameter and the other operating conditions are accounted for; the same rpm gives different surface speeds on different diameters.<\/strong> Surface speed in m\/s = \u03c0 \u00d7 drum diameter in metres \u00d7 rpm \u00f7 60. Record both diameter and rpm, then compare the tank arrangement, feed and magnetic system as well.<\/p><\/div><\/details>\n<details class=\"cv-faq-item\"><summary>Does a drier concentrate mean a higher iron grade?<\/summary><div class=\"cv-faq-answer\"><p><strong>Not if only water has been removed: dry-basis iron grade stays the same.<\/strong> Dewatering raises the solids percentage of the slurry. Improving dry-basis grade requires changing the solids composition, such as removing gangue. Report moisture and dry assay separately so a drainage improvement is not mistaken for mineral upgrading.<\/p><\/div><\/details>\n<details class=\"cv-faq-item\"><summary>Why does a cleaner reduce overall recovery when its own recovery is high?<\/summary><div class=\"cv-faq-answer\"><p><strong>The cleaner recovers a percentage of the material it receives, after any rougher loss has already occurred.<\/strong> Suppose the rougher recovers 95% of the feed&#8217;s target component and the cleaner retains 98% of that rougher product. With these two stages in series and no recycle or other streams, overall recovery is 0.95 \u00d7 0.98 \u00d7 100 = <strong>93.1%<\/strong>. For a circuit with recycle, calculate recovery from fresh feed and final product.<\/p><\/div><\/details>\n<details class=\"cv-faq-item\"><summary>Can a dense-media recovery figure be used as an iron-ore recovery target?<\/summary><div class=\"cv-faq-answer\"><p><strong>No. Medium recovery and ore concentration have different feeds, objectives and measurement conditions.<\/strong> Dense-media service recycles magnetite or ferrosilicon; ore concentration must also reject gangue and reach a product assay. Define the target component, feed condition and loss calculation for the actual duty before comparing results.<\/p><\/div><\/details>\n<details class=\"cv-faq-item\"><summary>What if the result improves after adjustment but gets worse again?<\/summary><div class=\"cv-faq-answer\"><p><strong>Compare the return of the problem with feed and equipment trends before changing the setting again.<\/strong> Check whether the change follows an ore blend, a solids or flow surge, buildup, spray blockage or wear. Repeat a matched baseline period and measure the affected stream. A recurring upstream change needs a feed-control solution; a restored setting that drifts physically needs its mechanical cause corrected.<\/p><\/div><\/details>\n<\/section>\n<\/article>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I judge magnetite losses from the color of the tailings?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Color can prompt an investigation, but it does not quantify magnetite loss or recovery. Take representative samples and measure dry tailings flow plus the relevant magnetic component. Use mineral identification when total Fe and magnetic response tell different stories. A hand magnet is a screening aid, not a quantitative recovery test.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can two drums be compared at the same rpm?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Only when diameter and the other operating conditions are accounted for; the same rpm gives different surface speeds on different diameters. Surface speed in m\/s = \u03c0 \u00d7 drum diameter in metres \u00d7 rpm \u00f7 60. Record both diameter and rpm, then compare the tank arrangement, feed and magnetic system as well.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a drier concentrate mean a higher iron grade?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Not if only water has been removed: dry-basis iron grade stays the same. Dewatering raises the solids percentage of the slurry. Improving dry-basis grade requires changing the solids composition, such as removing gangue. Report moisture and dry assay separately so a drainage improvement is not mistaken for mineral upgrading.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why does a cleaner reduce overall recovery when its own recovery is high?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The cleaner recovers a percentage of the material it receives, after any rougher loss has already occurred. Suppose the rougher recovers 95% of the feed's target component and the cleaner retains 98% of that rougher product. With these two stages in series and no recycle or other streams, overall recovery is 0.95 \u00d7 0.98 \u00d7 100 = 93.1% . For a circuit with recycle, calculate recovery from fresh feed and final product.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can a dense-media recovery figure be used as an iron-ore recovery target?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Medium recovery and ore concentration have different feeds, objectives and measurement conditions. Dense-media service recycles magnetite or ferrosilicon; ore concentration must also reject gangue and reach a product assay. Define the target component, feed condition and loss calculation for the actual duty before comparing results.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What if the result improves after adjustment but gets worse again?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Compare the return of the problem with feed and equipment trends before changing the setting again. Check whether the change follows an ore blend, a solids or flow surge, buildup, spray blockage or wear. Repeat a matched baseline period and measure the affected stream. A recurring upstream change needs a feed-control solution; a restored setting that drifts physically needs its mechanical cause corrected.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>For better wet drum magnetic separator recovery, stabilize the feed, slurry level and discharge before changing drum speed or the magnetic system. If recovery is low, find out which magnetic particles are leaving in the tailings. If recovery is good but concentrate grade is low, separate poor liberation from unwanted gangue carried into the concentrate. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4477,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5525","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/comments?post=5525"}],"version-history":[{"count":2,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5525\/revisions"}],"predecessor-version":[{"id":5607,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5525\/revisions\/5607"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media\/4477"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media?parent=5525"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/categories?post=5525"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/tags?post=5525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}