{"id":5550,"date":"2026-11-13T06:13:27","date_gmt":"2026-11-12T22:13:27","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5550"},"modified":"2026-10-30T13:47:38","modified_gmt":"2026-10-30T05:47:38","slug":"install-conveyor-metal-detector-without-cutting-belt","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/fr\/install-conveyor-metal-detector-without-cutting-belt\/","title":{"rendered":"Peut-on installer un d\u00e9tecteur de m\u00e9taux sur un convoyeur sans couper la bande ?"},"content":{"rendered":"\n<style>\n.cv-retrofit{--cv-primary:#374151;--cv-dark:#111827;--cv-soft:#f6f7f8;--cv-text:#222b33;--cv-border:#d7dde1;color:var(--cv-text);font-family:inherit;font-size:17px;line-height:1.75;overflow-wrap:break-word;}\n.cv-retrofit .cv-intro,.cv-retrofit .cv-section,.cv-retrofit .cv-toc{box-sizing:border-box;margin:0 0 24px;padding:22px;border:1px solid var(--cv-border);border-radius:16px;}\n.cv-retrofit .cv-intro,.cv-retrofit .cv-toc,.cv-retrofit .cv-contact{background:var(--cv-soft);}\n.cv-retrofit .cv-section{background:#fff;border-top:4px solid var(--cv-primary);box-shadow:0 2px 8px rgb(17 24 39 \/ 4%);scroll-margin-top:120px;}\n.cv-retrofit .cv-contact{background:var(--cv-soft);}\n.cv-retrofit h2,.cv-retrofit h3{color:var(--cv-dark);font-family:inherit;line-height:1.3;font-weight:700;overflow-wrap:anywhere;scroll-margin-top:120px;}\n.cv-retrofit h2{font-size:30px;margin:0 0 20px;}\n.cv-retrofit h3{font-size:24px;margin:28px 0 12px;}\n.cv-retrofit p{margin:0 0 16px;}\n.cv-retrofit p:last-child{margin-bottom:0;}\n.cv-retrofit a{color:var(--cv-dark);text-decoration:underline;text-underline-offset:3px;}\n.cv-retrofit a:hover{color:#374151;}\n.cv-retrofit a:focus-visible,.cv-retrofit summary:focus-visible,.cv-retrofit .cv-table-scroll:focus-visible{outline:3px solid #374151;outline-offset:4px;}\n.cv-retrofit ul,.cv-retrofit ol{padding-left:24px;margin:16px 0;}\n.cv-retrofit li{margin-bottom:10px;}\n.cv-retrofit strong{font-weight:700;}\n.cv-retrofit .cv-media{display:block;margin:0 0 20px;}\n.cv-retrofit .cv-media img{display:block;max-width:100%;height:auto;border-radius:10px;}\n.cv-retrofit .cv-table-scroll{overflow-x:auto;margin:20px 0;}\n.cv-retrofit table{border-collapse:collapse;width:100%;min-width:620px;font-size:inherit;line-height:1.6;}\n.cv-retrofit th,.cv-retrofit td{text-align:left;vertical-align:top;padding:13px 15px;border:1px solid var(--cv-border);}\n.cv-retrofit th{background:var(--cv-soft);color:var(--cv-dark);font-weight:700;}\n.cv-retrofit tbody tr:nth-child(even){background:#fafafa;}\n.cv-retrofit summary{cursor:pointer;color:var(--cv-dark);font-weight:700;line-height:1.5;}\n.cv-retrofit .cv-toc ul{margin-bottom:0;}\n.cv-retrofit .cv-toc a{white-space:normal;overflow-wrap:anywhere;}\n.cv-retrofit .cv-faq details{padding:18px 0;border-bottom:1px solid var(--cv-border);}\n.cv-retrofit .cv-faq details:last-child{border-bottom:0;}\n.cv-retrofit .cv-faq details[open] summary{margin-bottom:12px;}\n.cv-retrofit .cv-faq summary::marker,.cv-retrofit .cv-toc summary::marker{content:'+ ';}\n.cv-retrofit .cv-faq details[open]>summary::marker,.cv-retrofit .cv-toc details[open]>summary::marker{content:'\u2212 ';}\n@media(max-width:768px){\n.cv-retrofit{font-size:16px;}\n.cv-retrofit .cv-intro,.cv-retrofit .cv-section,.cv-retrofit .cv-toc{padding:18px;margin-bottom:18px;border-radius:12px;}\n.cv-retrofit .cv-section{border-top-width:3px;}\n.cv-retrofit h2{font-size:24px;}\n.cv-retrofit h3{font-size:20px;}\n.cv-retrofit th,.cv-retrofit td{padding:11px;}\n}\n<\/style>\n<article class=\"cv-retrofit\">\n<div class=\"cv-intro\"><p><strong>Yes\u2014you can install a conveyor metal detector without cutting the belt when you choose a detector designed to open around it.<\/strong> A split-frame or split-coil detector lets you assemble the sensing head around the existing belt. An underbelt detector offers another option when its sensing range suits the metal and material depth.<\/p>\n<p>Keeping the belt intact avoids making a new splice. You still need a planned shutdown for safe fitting, wiring and testing. Start with an openable frame, then check whether the existing belt, nearby steelwork and stopping distance suit the detection job.<\/p><\/div>\n<nav class=\"cv-toc\" aria-label=\"Article sections\"><details><summary>Find your installation question<\/summary><ul><li><a href=\"#detector-designs\">Which detector designs can be installed without cutting the belt?<\/a><\/li><li><a href=\"#belt-and-splice\">Can you keep the existing belt and metal splice?<\/a><\/li><li><a href=\"#installation-point\">What should you measure before choosing the installation point?<\/a><\/li><li><a href=\"#retrofit-steps\">How do you retrofit the detector around an uncut belt?<\/a><\/li><li><a href=\"#loaded-tests\">How do you prove the retrofit works under load?<\/a><\/li><li><a href=\"#choose-your-retrofit\">Choose the retrofit that protects the line<\/a><\/li><li><a href=\"#retrofit-faqs\">Conveyor metal detector retrofit FAQs<\/a><\/li><\/ul><\/details><\/nav>\n<section class=\"cv-section\" id=\"detector-designs\">\n<h2>Which detector designs can be installed without cutting the belt?<\/h2>\n<figure class=\"cv-media\"><img loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/09\/coverlan-ljt-b-tramp-metal-detector-hero.webp\" alt=\"Rectangular detector frame with bolted joints and a separate control enclosure\" width=\"1200\" height=\"900\" loading=\"lazy\" decoding=\"async\" style=\"display:block;max-width:100%;height:auto;object-fit:contain;\"><\/figure>\n<p><strong>Choose a purpose-built split-frame detector first when you need a surrounding sensing head on an existing, uncut belt.<\/strong> Its designated sections separate for installation and reconnect around the conveyor. Underbelt sensors avoid surrounding the belt, but the farthest metal target must remain within their useful detection range.<\/p>\n<div aria-label=\"Which detector designs can be installed without cutting the belt?\" class=\"cv-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>Detector design<\/th>\n<th>How the belt stays intact<\/th>\n<th>What decides whether it fits<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Split-frame or openable tunnel<\/td>\n<td>The designed joints open, allowing sections to pass around the belt.<\/td>\n<td>Space to move and reassemble the sections, loaded-belt clearance and belt compatibility.<\/td>\n<\/tr>\n<tr>\n<td>Underbelt sensor<\/td>\n<td>The sensor mounts below the carrying belt.<\/td>\n<td>Space below the belt and detection of the required target at the greatest distance from the sensor.<\/td>\n<\/tr>\n<tr>\n<td>Closed, one-piece head<\/td>\n<td>It may be possible to thread an accessible belt end through the opening during a larger conveyor rebuild.<\/td>\n<td>An actual belt-threading path; it cannot simply open around an endless belt.<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>The key word is <strong>designed<\/strong>. Do not saw through a sealed sensing head or undo housing parts that are not installation joints. A removable cover does not establish that the coil itself can split. Ask for an assembly drawing showing the designated opening and the route each section takes around the conveyor.<\/p>\n<p>For an existing bulk conveyor, our <a href=\"https:\/\/www.corvelanmag.com\/products\/ljt-b-tramp-metal-detector\/\">LJT-B split-frame tramp metal detector<\/a> is the first model to compare when preserving the belt is important. It is listed for installation around the existing belt without cutting it.<\/p>\n<p>If overhead access is blocked, compare an underbelt layout. However, a compact sensor that fits easily may miss a small target near the top of a deep load. Define that target and position before trading a surrounding frame for an underbelt sensor. Our <a href=\"https:\/\/www.corvelanmag.com\/product-category\/conveyor-metal-detector\/\">conveyor metal detector range<\/a> explains where the different LJT layouts fit.<\/p>\n<p>Openable probes are an established design approach: <a href=\"https:\/\/www.ceia.net\/industrial\/product.aspx?a=tsm\/d&amp;eng=&amp;lan=eng\" rel=\"nofollow noopener\" target=\"_blank\">CEIA&#8217;s TSM\/D description<\/a> also identifies a probe that opens for installation without cutting the conveyor belt.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"belt-and-splice\">\n<h2>Can you keep the existing belt and metal splice?<\/h2>\n<p><strong>Keep the existing belt only when its construction and joints suit the chosen detection system.<\/strong> A split frame solves access around the belt; metal inside the belt still affects the sensing field.<\/p>\n<h3 id=\"belt-and-splice-non-metallic-belt-with-a-non-metallic-splice\">Non-metallic belt with a non-metallic splice<\/h3>\n<p>This is the simplest starting point. Get the belt specification rather than judging its rubber surface. Record the reinforcement, splice material and any repair clips. Also look for embedded wire, trapped metal or past repairs that return to the sensor on every belt revolution.<\/p>\n<p>A belt with no metal reinforcement can still need an application check if its compounds are conductive. Keep the existing belt when its empty-belt signal is stable and the required target remains detectable with material present.<\/p>\n<h3 id=\"belt-and-splice-metal-clips-fasteners-or-repair-joints\">Metal clips, fasteners or repair joints<\/h3>\n<p>A metal joint can trigger the detector every lap. Some systems distinguish certain fasteners; others use a separate splice sensor to change detection while the joint passes. <strong>These functions differ by detector.<\/strong><\/p>\n<p>For example, <a href=\"https:\/\/buntingmagnetics.com\/product\/metal-detection\/tn-series-metal-detectors\" rel=\"nofollow noopener\" target=\"_blank\">Bunting&#8217;s TN77<\/a> describes ignoring non-magnetic belt components such as copper-alloy fasteners while detecting ferrous tramp metal and manganese steel. That does not establish that another detector can ignore the same joint while finding every non-ferrous contaminant.<\/p>\n<p>Other arrangements create a detection gap. <a href=\"https:\/\/www.mdiblue.com\/splice-detector-system\" rel=\"nofollow noopener\" target=\"_blank\">MDI&#8217;s splice detector description<\/a> explains that its system ignores the belt portion containing the splice. If the chosen system uses a bypass window, include that window in the protection decision: what happens to contamination travelling beside the joint?<\/p>\n<p>The LJT-B lists an optional splice detector. Send the joint material, width along the belt, repair locations and belt speed so its operation can be defined for your setup. Agree how detection near the joint will be tested. If uninterrupted coverage is essential and the proposed joint-handling mode interrupts it, compare a suitable non-metallic splice or a different inspection arrangement.<\/p>\n<p>Changing the splice is a separate belt-maintenance job. If the original joint must remain untouched, focus the comparison on a compatible detector or a separate inspection position.<\/p>\n<h3 id=\"belt-and-splice-steel-cord-belt-or-metal-mesh-belt\">Steel-cord belt or metal mesh belt<\/h3>\n<p>Metal reinforcement runs through the belt continuously. A splice sensor intended to recognize an occasional joint does not solve that continuous metal background. Start with the belt data sheet and the required contaminant sample, then assess a system specifically suited to that belt construction.<\/p>\n<p>If the existing belt and target cannot be separated reliably by the proposed detector, change the inspection arrangement. One option is a separate compatible inspection conveyor at a transfer point, provided the transfer preserves material flow and coverage. Do not buy a split frame solely because its mechanical opening fits the belt.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"installation-point\">\n<h2>What should you measure before choosing the installation point?<\/h2>\n<p><strong>Measure the assembly route, the loaded conveyor and the distance available for the line to react.<\/strong> Belt width alone leaves out the three things that can stop a retrofit: sections cannot reach their position, the belt or load hits the head, or detected metal travels beyond the protected point before the belt stops.<\/p>\n<h3 id=\"installation-point-allow-room-to-assemble-and-service-the-frame\">Allow room to assemble and service the frame<\/h3>\n<p>Take a front view and side view at the proposed location. Mark the carrying belt, return belt, rollers, stringers, guards, walkway, covers and cables. Measure the spaces beside, above and below the belt through which each detector section must move.<\/p>\n<p>Then compare those measurements with the detector&#8217;s assembly and outline drawings. A head can fit in its final position while a side section cannot be brought past a walkway. In that case, choose another location or arrange an engineered access change before shutdown.<\/p>\n<p>For running clearance, use the <strong>loaded belt shape and its normal movement<\/strong>: trough profile, belt sag, tracking variation, maximum material depth and largest lumps. Include the return run if it passes near the lower sensor. Keep the belt and product clear of the sensing head throughout that operating range.<\/p>\n<p>Use conveyor drawings and safe observations of normal operation to identify that movement. Take physical measurements under isolation. Measure material depth from the local belt surface to the top of the load at the proposed detector, rather than from the conveyor frame; include the highest normal lumps.<\/p>\n<h3 id=\"installation-point-keep-surrounding-metal-within-the-detector-s-installation-limits\">Keep surrounding metal within the detector&#8217;s installation limits<\/h3>\n<p>The space where nearby metal must be restricted is often called the <strong>metal-free zone<\/strong>. Its required size depends on the detector and the metal&#8217;s position and movement. Obtain the selected model&#8217;s installation drawing; do not borrow a clearance distance from an unrelated tunnel detector.<\/p>\n<p>List steel decking, skirts, cross-members and idlers in that zone. Decide which need relocation, an approved non-metallic replacement or the specified electrical isolation. Removing a roller can also change belt sag and support, so include that mechanical change in the design.<\/p>\n<p>Loose metal joints can form changing electrical loops and produce false signals. <a href=\"https:\/\/www.mdiblue.com\/faqs\" rel=\"nofollow noopener\" target=\"_blank\">MDI&#8217;s installation FAQs<\/a> explain this interference mechanism. The repair must suit the structure: stabilize or isolate the identified joint as designed. Do not remove load-bearing bracing or protective earth connections to stop nuisance alarms.<\/p>\n<p>Also mark nearby motors, variable-frequency drives, power cables and magnetic separators. Plan the sensor cable route with the detector wiring instructions, separate from avoidable power-cable interference.<\/p>\n<h3 id=\"installation-point-leave-enough-distance-for-the-stop-action\">Leave enough distance for the stop action<\/h3>\n<p><strong>A detector must be far enough upstream for the metal to remain before the hazard after the complete stop sequence.<\/strong> The <a href=\"https:\/\/eriez.com\/Documents\/Literature\/IOMs\/Metal-Detection\/MM-1260-Analog-Eriez-Model-1260-Metal-Detector-IOM.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez Model 1260 installation manual<\/a> makes this location requirement explicit.<\/p>\n<p>For an initial screen, use:<\/p>\n<p><strong>Travel before stopping = belt speed \u00d7 response delay + travel after the stop command.<\/strong><\/p>\n<p>Suppose a belt runs at 2 m\/s, detection-to-stop-command delay is 0.3 s, and measured travel after that command is 3.2 m under the assessed load. Total travel is <strong>2 \u00d7 0.3 + 3.2 = 3.8 m<\/strong>, before any site-required allowance. A location only 3 m before the hazard is too close for these inputs. Move the detector upstream or have the stopping system improved, then repeat the test.<\/p>\n<p>Keep the timing boundaries clear. If your measured stopping travel already starts at detection, do not add the response distance again. For final placement, use a controlled end-to-end stopping test under the hardest normal operating condition. Include material rolling or sliding after the belt slows. A controller&#8217;s output hold time is not the conveyor&#8217;s stopping time.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"retrofit-steps\">\n<h2>How do you retrofit the detector around an uncut belt?<\/h2>\n<p><strong>Prepare the supports and controls first, then install the split sections during an isolated shutdown and commission the complete detection-to-response chain.<\/strong> The belt remains joined; the detector opens at its intended assembly joints.<\/p>\n<h3 id=\"retrofit-steps-1-complete-the-preparation-before-stopping-production\">1. Complete the preparation before stopping production<\/h3>\n<p>Have the selected head&#8217;s assembly drawing, mounting layout and wiring diagram available at the conveyor. Identify the matching frame sections, fasteners, insulating parts and cables. Prepare the approved supports, access equipment and cable route before the installation window.<\/p>\n<p>Separate the work into mechanical changes, electrical work and commissioning. Put each task into the shutdown schedule and identify which can be completed beforehand. This gives a useful downtime estimate; \u201cno belt cutting\u201d alone does not.<\/p>\n<h3 id=\"retrofit-steps-2-isolate-the-conveyor-and-material-feed\">2. Isolate the conveyor and material feed<\/h3>\n<p>Stop incoming material, clear the work area and isolate the conveyor and equipment that could feed or move it. Control stored energy and prevent unexpected belt movement under the site&#8217;s lockout procedure. An alarm reset or an emergency-stop button is not the energy-isolation method.<\/p>\n<p>Use planned lifting and access points to handle the sections. Do not use the sensing opening as a lifting point. Where guards need removal for access, keep the affected equipment isolated until guarding is restored.<\/p>\n<h3 id=\"retrofit-steps-3-fit-the-designated-sections-and-supports\">3. Fit the designated sections and supports<\/h3>\n<p>Bring each section around the belt along the planned route. Reassemble at the manufacturer&#8217;s match marks and joints, with the specified insulating parts, hardware and tightening procedure. Keep the frame square and unstressed; do not pull a misaligned assembly into position with its bolts.<\/p>\n<p>Use the loaded-conveyor dimensions to set the head position. The sensing head must not become a belt support or receive impact from lumps. Complete any designed changes to decking, idlers or skirts, then recheck the resulting belt path.<\/p>\n<p>Keep the original matched sensing components together. Do not substitute another head section, extend a coil cable or change an isolation arrangement without the model-specific design information.<\/p>\n<h3 id=\"retrofit-steps-4-connect-the-detector-to-the-required-line-action\">4. Connect the detector to the required line action<\/h3>\n<p>The electrician needs the supplied output type, voltage, contact rating and control schematic. Match these to the PLC or motor-control input; an electrical output is not automatically a voltage-free contact. Use the required interface rather than connecting unknown terminals together.<\/p>\n<p>Decide how an alarm remains recorded, who removes the metal and what permits restart. If the process requires a latched stop, the output resetting must not restart the conveyor while the contamination remains. Coordinate the upstream feed so a stopped belt does not keep receiving material.<\/p>\n<h3 id=\"retrofit-steps-5-restore-guarding-and-prepare-controlled-tests\">5. Restore guarding and prepare controlled tests<\/h3>\n<p>Remove tools and installation debris, secure cables and restore guards. Establish a commissioning area and a way to recover every test piece before it can reach the crusher or other hazard. Set the required target, settings and pass conditions before starting the sequence below.<\/p>\n<\/section>\n<section class=\"cv-section\" id=\"loaded-tests\">\n<h2>How do you prove the retrofit works under load?<\/h2>\n<p><strong>Test belt stability, target detection and the actual line response as separate checks, then run them together with representative material.<\/strong> An empty-belt alarm test shows much less than a loaded test at the difficult target position.<\/p>\n<p>First identify the test object by metal, dimensions, shape and orientation. Record normal and maximum belt speed, material depth and relevant changes in moisture or mineral content. Agree the test positions and repeat passes before testing, rather than selecting the easiest successful result afterwards.<\/p>\n<ol>\n<li><strong>Run the empty belt through complete revolutions.<\/strong> Include every splice and repair area. Log whether alarms follow the same belt location or a nearby machine starting. Correct background instability before increasing sensitivity.<\/li>\n<li><strong>Run representative material without the test object.<\/strong> Include the deepest normal load and difficult material condition. If the signal changes, separate material effects from the belt and surrounding equipment before setting the working threshold.<\/li>\n<li><strong>Pass the target through the required positions.<\/strong> Include the hardest expected locations across the belt and through the load depth. For an underbelt sensor, pay particular attention to the target farthest above it. Use a controlled test carrier or placement method, fit it while the equipment is isolated, and recover it through the planned safe procedure; never reach into a running conveyor.<\/li>\n<li><strong>Exercise the complete response.<\/strong> Record the detector event, output, stop or marking action and final target position. Check reset and restart behavior. If a joint-handling feature is used, include target positions before, beside and after the joint to establish its actual coverage.<\/li>\n<\/ol>\n<p>Record each condition, setting, pass and outcome. If the target is detected only some of the time, record that condition as a failure against an every-pass requirement. Do not average it away with easier passes. Once an installation or setting changes, repeat the affected tests and the linked line response.<\/p>\n<div aria-label=\"How do you prove the retrofit works under load?\" class=\"cv-table-scroll\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr>\n<th>What happens<\/th>\n<th>What the pattern suggests<\/th>\n<th>What to do next<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>An alarm returns at the same point every belt lap.<\/td>\n<td>Splice, repair or belt contamination may be involved.<\/td>\n<td>Match the event to the marked belt position; inspect that area under isolation and review joint handling.<\/td>\n<\/tr>\n<tr>\n<td>Alarms appear with vibration or a nearby motor starting.<\/td>\n<td>Mounting, moving metal or electrical interference may be involved.<\/td>\n<td>Log the machine state; inspect support joints and cable routes, then repeat the same condition after correction.<\/td>\n<\/tr>\n<tr>\n<td>Empty-belt tests pass, but loaded targets are missed.<\/td>\n<td>Target position, material background or changed clearance may be involved.<\/td>\n<td>Compare the same target and orientation at defined depths; review the aperture or sensor layout if the hard position remains undetected.<\/td>\n<\/tr>\n<tr>\n<td>The detector alarms, but metal moves beyond the protected point.<\/td>\n<td>The output, interlock, delay or stopping travel needs attention.<\/td>\n<td>Trace the event through the control chain and measure the complete travel again; move the detector upstream if needed.<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>The goal is <strong>stable operation with the required target detected and the intended action completed<\/strong>. Reducing sensitivity until nuisance alarms disappear is not a fix if the required metal then passes through.<\/p>\n<p>When the belt stops for manual metal removal, isolate it and the related feed before anyone touches the belt or material. Detection provides the signal; recovering the metal is a separate task.<\/p>\n<\/section>\n<section class=\"cv-section cv-contact\" id=\"choose-your-retrofit\">\n<h2>Choose the retrofit that protects the line<\/h2>\n<p>To install a conveyor metal detector without cutting the belt, start with a purpose-built split frame. Keep the belt when its construction suits detection, make room for assembly and the loaded conveyor, and test the full response before returning the line to service. If a belt joint, deep load or short stopping distance defeats the required protection, change that part of the arrangement before accepting the retrofit.<\/p>\n<p>For an LJT-B application, send us the belt width and construction, splice details, target metal, normal and maximum material depth, belt speed and required alarm or stop action. Add the available space beside and below the conveyor and the distance to the equipment you need to protect. We can review the model, installation interfaces and control needs together.<\/p>\n<p>Use our <a href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">contact form to request a conveyor detector review<\/a>. Put the key measurements in the message first; if drawings or photos are needed, we can arrange how to receive them after contact.<\/p>\n<\/section>\n<section class=\"cv-section cv-faq faq\" id=\"retrofit-faqs\">\n<h2>Conveyor metal detector retrofit FAQs<\/h2>\n<details><summary>Can installation be done while the conveyor keeps running?<\/summary>\n<p><strong>No. Fitting sections, altering supports and connecting controls require a planned, isolated work period.<\/strong> A split frame saves the belt-cutting and resplicing operation. It does not make work around moving belts safe.<\/p>\n<\/details><details><summary>Does a split-frame detector detect every type of metal?<\/summary>\n<p><strong>No. Split-frame describes how the head opens, not which metals or sizes it detects.<\/strong> Select the detection technology and test target separately. A detector intended to ignore a particular metal fastener may also treat other objects of that metal differently.<\/p>\n<\/details><details><summary>Can the return belt affect a detector installed around the carrying belt?<\/summary>\n<p><strong>Yes, if the return run or its metal joints enter the sensing field or reduce clearance.<\/strong> Include both belt runs in the section drawing. If alarms follow a joint, compare its passage on the carrying and return runs before changing the detection settings.<\/p>\n<\/details><details><summary>Can existing brackets and the old control box be reused?<\/summary>\n<p><strong>Only when they match the replacement detector&#8217;s mechanical and electrical requirements.<\/strong> Compare bracket loads, dimensions and isolation with the new drawing. Separately compare power, outputs, input logic and cable requirements. A head that bolts into the old position is not automatically electrically compatible.<\/p>\n<\/details><details><summary>Can I place the detector beside an existing magnetic separator?<\/summary>\n<p><strong>It can share the conveyor line, but its location must account for the magnet, moving metal and electrical equipment.<\/strong> Show the separator and its discharge path on the layout. Reproduce their normal operation during the detector&#8217;s stability and target tests; no single spacing fits every pairing.<\/p><\/details>\n<\/section>\n<\/article>\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can installation be done while the conveyor keeps running?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Fitting sections, altering supports and connecting controls require a planned, isolated work period. A split frame saves the belt-cutting and resplicing operation. It does not make work around moving belts safe.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a split-frame detector detect every type of metal?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Split-frame describes how the head opens, not which metals or sizes it detects. Select the detection technology and test target separately. A detector intended to ignore a particular metal fastener may also treat other objects of that metal differently.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can the return belt affect a detector installed around the carrying belt?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, if the return run or its metal joints enter the sensing field or reduce clearance. Include both belt runs in the section drawing. If alarms follow a joint, compare its passage on the carrying and return runs before changing the detection settings.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can existing brackets and the old control box be reused?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Only when they match the replacement detector's mechanical and electrical requirements. Compare bracket loads, dimensions and isolation with the new drawing. Separately compare power, outputs, input logic and cable requirements. A head that bolts into the old position is not automatically electrically compatible.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I place the detector beside an existing magnetic separator?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It can share the conveyor line, but its location must account for the magnet, moving metal and electrical equipment. Show the separator and its discharge path on the layout. Reproduce their normal operation during the detector's stability and target tests; no single spacing fits every pairing.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Yes\u2014you can install a conveyor metal detector without cutting the belt when you choose a detector designed to open around it. A split-frame or split-coil detector lets you assemble the sensing head around the existing belt. An underbelt detector offers another option when its sensing range suits the metal and material depth. Keeping the belt [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4179,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5550","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5550","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/comments?post=5550"}],"version-history":[{"count":1,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5550\/revisions"}],"predecessor-version":[{"id":5632,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/posts\/5550\/revisions\/5632"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media\/4179"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/media?parent=5550"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/categories?post=5550"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/fr\/wp-json\/wp\/v2\/tags?post=5550"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}