{"id":5202,"date":"2026-09-21T09:00:32","date_gmt":"2026-09-21T01:00:32","guid":{"rendered":"https:\/\/www.corvelanmag.com\/?p=5202"},"modified":"2026-11-22T11:15:13","modified_gmt":"2026-11-22T03:15:13","slug":"magnetic-field-gradient-vs-gauss","status":"publish","type":"post","link":"https:\/\/www.corvelanmag.com\/ru\/magnetic-field-gradient-vs-gauss\/","title":{"rendered":"\u0413\u0440\u0430\u0434\u0438\u0435\u043d\u0442 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0433\u043e \u043f\u043e\u043b\u044f \u0438 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u0430\u044f \u0438\u043d\u0434\u0443\u043a\u0446\u0438\u044f \u0432 \u0433\u0430\u0443\u0441\u0441\u0430\u0445 \u043f\u0440\u0438 \u043c\u0430\u0433\u043d\u0438\u0442\u043d\u043e\u0439 \u0441\u0435\u043f\u0430\u0440\u0430\u0446\u0438\u0438"},"content":{"rendered":"\n<style>\n.cvl-field-guide {\n  --cvl-primary: #061e38;\n  --cvl-action: #0b2d52;\n  --cvl-text: #202d3d;\n  --cvl-border: #dbe3eb;\n  --cvl-soft: #eff5fa;\n  color: var(--cvl-text);\n  font: inherit;\n  font-size: 17px;\n  line-height: 1.75;\n  overflow-wrap: anywhere;\n}\n.cvl-field-guide .field-card {\n  box-sizing: border-box;\n  display: block;\n  padding: 22px;\n  margin: 0 0 24px;\n  border: 1px solid var(--cvl-border);\n  border-top: 4px solid var(--cvl-primary);\n  border-radius: 16px;\n  background: #fff;\n  box-shadow: 0 2px 10px #061e3809;\n}\n.cvl-field-guide .field-intro,\n.cvl-field-guide .field-nav,\n.cvl-field-guide [data-article-section=\"cta\"] { background: var(--cvl-soft); }\n.cvl-field-guide .field-card:last-child { margin-bottom: 0; }\n.cvl-field-guide h2,\n.cvl-field-guide h3,\n.cvl-field-guide .field-nav-title { color: var(--cvl-primary); }\n.cvl-field-guide h2,\n.cvl-field-guide h3 {\n  font-family: inherit;\n  font-weight: 650;\n  line-height: 1.3;\n}\n.cvl-field-guide h2 { font-size: 30px; margin: 0 0 14px; }\n.cvl-field-guide h3 { font-size: 24px; margin: 22px 0 10px; }\n.cvl-field-guide p { margin: 0 0 12px; }\n.cvl-field-guide p:last-child,\n.cvl-field-guide ul:last-child,\n.cvl-field-guide ol:last-child { margin-bottom: 0; }\n.cvl-field-guide ul,\n.cvl-field-guide ol { margin: 0 0 14px; padding-inline-start: 1.35em; }\n.cvl-field-guide li + li { margin-top: 4px; }\n.cvl-field-guide a { font: inherit; color: var(--cvl-action); text-decoration: underline; text-underline-offset: .15em; }\n.cvl-field-guide a:focus-visible,\n.cvl-field-guide .field-table:focus-visible { outline: 2px solid var(--cvl-action); outline-offset: 3px; }\n.cvl-field-guide section[id] { scroll-margin-block-start: 95px; }\n.cvl-field-guide .field-media {\n  display: block;\n  clear: both;\n  float: none;\n  margin: 14px 0 16px;\n}\n.cvl-field-guide .field-media img {\n  display: block;\n  float: none;\n  max-width: 100%;\n  height: auto;\n  margin-inline: auto;\n  border-radius: 9px;\n}\n.cvl-field-guide .field-table { overflow-x: auto; margin: 12px 0 16px; border: 1px solid var(--cvl-border); border-radius: 10px; }\n.cvl-field-guide .field-table table { border-collapse: collapse; width: 100%; min-width: 27rem; margin: 0; }\n.cvl-field-guide .field-table th,\n.cvl-field-guide .field-table td { padding: 8px 10px; border: 0; border-bottom: 1px solid var(--cvl-border); }\n.cvl-field-guide .field-table thead th { background: var(--cvl-action); color: #fff; text-align: start; }\n.cvl-field-guide .field-table tbody tr:nth-child(even) { background: var(--cvl-soft); }\n.cvl-field-guide .field-table tbody tr:last-child > * { border-bottom: 0; }\n.cvl-field-guide .field-table :is(th, td):nth-child(n+2) { text-align: end; }\n.cvl-field-guide .field-button {\n  display: inline-block;\n  color: #fff;\n  background: var(--cvl-action);\n  padding: 8px 14px;\n  border-radius: 8px;\n  font-weight: 650;\n}\n.cvl-field-guide [data-article-section=\"faq\"] .level3 + .level3 { border-top: 1px solid var(--cvl-border); margin-top: 17px; }\n@media (max-width: 768px) {\n  .cvl-field-guide { font-size: 16px; }\n  .cvl-field-guide .field-card { padding: 18px; margin-bottom: 18px; border-radius: 12px; border-top-width: 3px; }\n  .cvl-field-guide h2 { font-size: 24px; }\n  .cvl-field-guide h3 { font-size: 20px; }\n}\n<\/style>\n<div class=\"cvl-field-guide\" lang=\"en-US\">\n<div class=\"field-card field-intro\"><p><strong>Gauss tells you the magnetic flux density at one point. The magnetic field gradient tells you how quickly the field changes across a distance.<\/strong> To compare magnetic separators, ask for field readings and their change where the particles actually travel. Then run representative material at the feed rate you need and check both the cleaned product and the reject stream.<\/p>\n<p>If two quotes list the same surface gauss, start by marking the particle path on the installation drawing. The belt, liner, feed depth, and pole layout can put the particles in very different parts of the field. That difference can change which separator you take to trial.<\/p>\n<\/div><nav aria-label=\"On this page\" class=\"field-card field-nav\" data-article-section=\"navigation\"><p class=\"field-nav-title\"><strong>On this page<\/strong><\/p><ol><li><a href=\"#gauss-gradient\">Magnetic Field Gradient vs Gauss: What&#8217;s the Difference?<\/a><\/li><li><a href=\"#particle-force\">How Does the Gradient Help Capture Fine Iron?<\/a><\/li><li><a href=\"#working-zone\">Where Should You Compare the Field on an Installed Separator?<\/a><\/li><li><a href=\"#gradient-example\">How Do You Estimate a Gradient From Gauss Readings?<\/a><\/li><li><a href=\"#field-map\">How Do You Measure and Map a Separator&#8217;s Field?<\/a><\/li><li><a href=\"#separator-choice\">Which Separator Layout Fits Your Material?<\/a><\/li><li><a href=\"#compare-evidence\">When Do You Need a Field Map, Pull Test, or Material Trial?<\/a><\/li><li><a href=\"#capture-trouble\">Why Can Capture Fall While the Gauss Check Stays Steady?<\/a><\/li><li><a href=\"#trial-plan\">How Do You Run a Material Trial That Supports a Decision?<\/a><\/li><li><a href=\"#approval\">What Should You Put on the Quote and Acceptance Plan?<\/a><\/li><li><a href=\"#questions\">Questions About Gauss and Magnetic Field Gradient<\/a><\/li><\/ol><\/nav><section class=\"level2 field-card\" id=\"gauss-gradient\">\n<h2>Magnetic Field Gradient vs Gauss: What&#8217;s the Difference?<\/h2>\n<p><strong>Gauss describes a field reading at a specific point. A gradient describes the change in the field per unit of distance, along a stated direction.<\/strong> A quote can report a high point reading even when the field changes very little across the passage the material uses.<\/p>\n<section class=\"level3\" id=\"what-does-a-gauss-reading-tell-you\">\n<h3>What does a gauss reading tell you?<\/h3>\n<p><strong>A gaussmeter reads magnetic flux density, written as B.<\/strong> Ask where the probe was placed and whether the value represents a single component, a field magnitude, or a peak found while scanning. In an equipment quote, the phrase <em>field strength<\/em> often refers to B. On a field report, identify B explicitly because H is a separate magnetic quantity. <strong>1 tesla (T) = 10,000 gauss (G).<\/strong> That puts 8,000 G and 0.8 T on the same scale. <a href=\"https:\/\/www.nist.gov\/document\/unitschartpdf\" rel=\"nofollow noopener\" target=\"_blank\">NIST&#8217;s magnetic units chart<\/a> lists the units for B and H separately.<\/p>\n<\/section>\n<section class=\"level3\" id=\"what-does-a-gradient-reading-tell-you\">\n<h3>What does a gradient reading tell you?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"What does a gradient reading tell you?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-magnetic-field-point-value-and-gradient-20261122.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>A gradient tells you how much the measured field changes per millimeter along a specified line.<\/strong> For a one-line comparison, that change can be given in G\/mm or T\/m. <strong>1 G\/mm = 0.1 T\/m.<\/strong> Give the reference face, the line along which you measured, and the field quantity you tracked. A field-line drawing shows the pattern and direction of the field. Use readings at known positions to get a numeric gradient.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"particle-force\">\n<h2>How Does the Gradient Help Capture Fine Iron?<\/h2>\n<p><strong>A field that changes across a particle&#8217;s path can pull a magnetically responsive particle toward a pole or matrix strand.<\/strong> The particle has to move far enough to reach the collection zone while the feed is still passing through it.<\/p>\n<section class=\"level3\" id=\"how-do-b-and-the-gradient-act-together\">\n<h3>How do B and the gradient act together?<\/h3>\n<p><strong>For small, weakly magnetic particles in the linear range, the force increases with both B and the local gradient for a given particle.<\/strong> The force along a chosen direction is proportional to particle volume, effective magnetic susceptibility relative to the carrier, and <strong>B \u00d7 dB\/dx<\/strong>. Here B is the local field magnitude and x is distance along that direction. Susceptibility describes how readily the particle responds to the field. A high B helps magnetize that particle. A steep change over distance helps move it. <a href=\"https:\/\/www.dextermag.com\/wp-content\/uploads\/2023\/10\/Dexter_HGMS_White_Paper.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Hatch and Stelter&#8217;s separator study<\/a> derives the force relationship and maps it across example gaps.<\/p>\n<p>That relationship is a useful design guide for weakly magnetic particles. Strongly magnetic pieces can approach saturation, where further increases in field produce much less change in their magnetization. Compare those pieces by grade, size, shape, distance, and actual capture under flow. A steel sphere used for a pull test and an iron-bearing mineral grain can respond very differently.<\/p>\n<\/section>\n<section class=\"level3\" id=\"why-might-a-particle-pass-a-strong-magnet\">\n<h3>Why might a particle pass a strong magnet?<\/h3>\n<p><strong>The particle has to reach the collection surface and stay there long enough to be separated.<\/strong> At higher feed speeds, it spends less time in the working zone. In a liquid, drag can oppose the sideways motion toward the collector. In dry bulk, a deep or clumped feed can carry a fine particle past that zone before the magnet can change its path. After contact, flowing material can dislodge some captured particles. Check the clean outlet over the entire cleaning cycle to see whether capture falls off as the magnet loads.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"working-zone\">\n<h2>Where Should You Compare the Field on an Installed Separator?<\/h2>\n<p><strong>Compare readings along the routes the target particles can actually take, including the far side of the feed bed or an edge where material can bypass the strongest field.<\/strong> Start with the as-installed cross section and draw the likely paths at normal and peak production.<\/p>\n<section class=\"level3\" id=\"which-surface-is-the-distance-measured-from\">\n<h3>Which surface is the distance measured from?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"Which surface is the distance measured from?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-magnetic-separator-working-distance-and-particle-path-20261122.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>Put the zero point on a repeatable surface, such as the outside face of the liner or the top of the belt.<\/strong> Name that surface on the drawing. If the dimensions start at the bare pole, account for the belt, cover, liner, air gap, and particle position as applicable. If the dimensions start at the product-facing surface, record the layers behind it as part of the test configuration. In both cases, you can plot the probe positions from the same reference. For conveyor geometry and practical ways to measure the gap, see our <a href=\"https:\/\/www.corvelanmag.com\/magnetic-separator-working-distance\/\">magnetic separator working distance guide<\/a>.<\/p>\n<\/section>\n<section class=\"level3\" id=\"what-changes-with-a-deep-or-uneven-feed-bed\">\n<h3>What changes with a deep or uneven feed bed?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"What changes with a deep or uneven feed bed?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-coal-working-distance-check-20260907-002407.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>A deep bed increases the distance to the particles on the far side.<\/strong> For an overhead magnet, check particles near the belt. For a roll under the feed, check particles near the top of the bed. A gravity chute can carry material around a concentrated zone if the stream favors one side. Check these paths in the loaded machine. If spreading or thinning the feed improves removal at the same magnet setting, review the feed arrangement and the width needed to hold throughput. <a href=\"https:\/\/eriez.com\/Documents\/Technical-Papers\/TheTrueValueofMagneticSeparatorsandMetalDetectors_BulkHandling.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s bulk-handling technical paper<\/a> discusses how pole design and conveyor layout affect the field available for pickup.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"gradient-example\">\n<h2>How Do You Estimate a Gradient From Gauss Readings?<\/h2>\n<p><strong>Subtract the two field readings and divide by the distance between them.<\/strong> The result is an average slope across that interval along the measured line. Use the same field quantity, direction, and distance reference for both separators.<\/p>\n<section class=\"level3\" id=\"how-do-two-equal-surface-readings-compare-at-depth\">\n<h3>How do two equal surface readings compare at depth?<\/h3>\n<p><strong>Equal surface readings can give different slopes over the same interval.<\/strong> The table uses two hypothetical maps of the field magnitude along the same line away from the magnet.<\/p>\n<div aria-label=\"Field readings and average slopes at three distances\" class=\"field-table\" role=\"region\" tabindex=\"0\"><table>\n<thead>\n<tr class=\"header\">\n<th scope=\"col\">Distance from the same reference face<\/th>\n<th scope=\"col\" style=\"text-align: right;\">Separator A<\/th>\n<th scope=\"col\" style=\"text-align: right;\">Separator B<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr class=\"odd\">\n<th scope=\"row\" style=\"text-align: start;\">0 mm<\/th>\n<td style=\"text-align: right;\">10,000 G<\/td>\n<td style=\"text-align: right;\">10,000 G<\/td>\n<\/tr>\n<tr class=\"even\">\n<th scope=\"row\" style=\"text-align: start;\">10 mm<\/th>\n<td style=\"text-align: right;\">6,000 G<\/td>\n<td style=\"text-align: right;\">8,000 G<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th scope=\"row\" style=\"text-align: start;\">20 mm<\/th>\n<td style=\"text-align: right;\">5,300 G<\/td>\n<td style=\"text-align: right;\">6,200 G<\/td>\n<\/tr>\n<tr class=\"even\">\n<th scope=\"row\" style=\"text-align: start;\">Average slope from 0 to 10 mm<\/th>\n<td style=\"text-align: right;\">\u2212400 G\/mm<\/td>\n<td style=\"text-align: right;\">\u2212200 G\/mm<\/td>\n<\/tr>\n<tr class=\"odd\">\n<th scope=\"row\" style=\"text-align: start;\">Average slope from 10 to 20 mm<\/th>\n<td style=\"text-align: right;\">\u221270 G\/mm<\/td>\n<td style=\"text-align: right;\">\u2212180 G\/mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p>For Separator B at 10\u201320 mm, the average is <strong>(6,200 \u2212 8,000) G \u00f7 10 mm = \u2212180 G\/mm = \u221218 T\/m<\/strong>. The minus sign means that B falls as distance from the reference face increases. The size of the average drop is 180 G\/mm. Closer readings around the point that matters give a better estimate of the local slope when the curve bends sharply.<\/p>\n<\/section>\n<section class=\"level3\" id=\"which-separator-would-you-test-first\">\n<h3>Which separator would you test first?<\/h3>\n<p><strong>Test B first if the working zone spans 10\u201320 mm in this example.<\/strong> It has a higher B at both measured points and a steeper average change across that interval. If the particles pass within the first <strong>0\u201310 mm<\/strong>, A has the steeper average slope there and merits a closer map in that zone. Take more readings around the actual capture point and compare both B and its local change before using either map to rank a thin-feed setup. Run the same material in both candidates if the closer maps leave the choice open.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"field-map\">\n<h2>How Do You Measure and Map a Separator&#8217;s Field?<\/h2>\n<p><strong>Measure at marked positions with a calibrated Hall-probe gaussmeter. Use the same setup twice to see how well the readings repeat.<\/strong> Measure along the route that matters for capture and across the working width where bypass is possible.<\/p>\n<section class=\"level3\" id=\"how-do-you-place-and-orient-the-probe\">\n<h3>How do you place and orient the probe?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"How do you place and orient the probe?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-qc-gauss-meter-test-20260906-182936-3.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>Choose an axial or transverse probe with a sensing axis suited to the field component being measured.<\/strong> Give that orientation in the report. Use repeatable nonmagnetic spacers or a fixture, and position the sensor&#8217;s active area at the intended distance. Near a pole edge, a small position shift or a large sensing area can change the reading. The <a href=\"https:\/\/www.lakeshore.com\/docs\/default-source\/product-downloads\/manuals\/425manual.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Lake Shore Model 425 gaussmeter manual<\/a> explains how probe orientation and active area affect measurements in a steep gradient. Follow the meter&#8217;s zero and calibration procedure. Where a check requires opening guards, follow the site&#8217;s isolation procedure and the separator manual.<\/p>\n<\/section>\n<section class=\"level3\" id=\"what-should-a-field-map-show\">\n<h3>What should a field map show?<\/h3>\n<p><strong>Show where each reading was taken and which field quantity it represents.<\/strong> Record the model and assembly revision, installed covers or belt, temperature and coil setting as applicable, probe type and sensing axis, a marked zero point, distances, and lateral positions. Label each series by the component or magnitude plotted. Repeat points using the same fixture and note unusually large variation. For a peak value, state the scan area and report where the peak occurs. If one quote lists a surface maximum and another lists a minimum at a set gap, request both readings on the same drawing before ranking them.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"separator-choice\">\n<h2>Which Separator Layout Fits Your Material?<\/h2>\n<p><strong>Choose the layout that routes the target particle through a usable field and gives the captured material a clear exit.<\/strong> Dry weakly magnetic mineral grains, tramp iron in a gravity chute, and fine particles in slurry call for different tests.<\/p>\n<section class=\"level3\" id=\"dry-minerals-with-weakly-magnetic-grains\">\n<h3>Dry minerals with weakly magnetic grains<\/h3>\n<p>A high-intensity magnetic roll is a good candidate when dry feed can form a <strong>thin, even layer<\/strong> and the unwanted grains are already separate from the valuable mineral. The belt carries particles close to the roll. The magnetic fraction follows the roll farther before leaving, and a splitter divides the material paths. Run narrow size fractions if the feed has a wide size spread, and measure how much saleable mineral goes into the magnetic stream when you adjust speed or splitter position. If iron is locked inside the valuable grains, check mineral liberation before increasing the field. See our <a href=\"https:\/\/www.corvelanmag.com\/products\/magnetic-roller-separator\/\">high-intensity magnetic roller separator<\/a> for feed conditions and stage options.<\/p>\n<\/section>\n<section class=\"level3\" id=\"dry-powders-and-granules-with-tramp-iron\">\n<h3>Dry powders and granules with tramp iron<\/h3>\n<p>For free-flowing dry bulk in a gravity line, place the capture zone across the material path. Look for a stable flow through the opening and enough space for cleaning and reject discharge. Damp feed or high iron loading can change the flow and the time between cleanings. Check the cleaned outlet from the start to the end of a representative run, especially after a feed surge. See our <a href=\"https:\/\/www.corvelanmag.com\/products\/pipeline-magnetic-separator\/\">pipeline magnetic separator for dry bulk<\/a> for gravity chutes and enclosed dry transfer lines. Pressure conveying and liquid service call for equipment designed for those duties.<\/p>\n<\/section>\n<section class=\"level3\" id=\"wet-feed-with-fine-magnetic-particles\">\n<h3>Wet feed with fine magnetic particles<\/h3>\n<p>Consider a high-gradient matrix separator when fine, magnetically responsive particles in slurry need to pass close to many collection sites. The matrix concentrates the field around narrow elements. Compare the applied field with the matrix and flow configuration specified separately. Check feed solids, flow, and the cleaning or flushing cycle with representative slurry. If a finer matrix restricts the flow or loads up before the planned cleaning point, compare matrix options at the required throughput. <a href=\"https:\/\/www.eriez.com\/Products\/Magnetic-Separation\/Magnetic-Processing-Concentration\/Magnetic-Separation-Solutions-for-Wet-Minerals-Processing\/High-Intensity-Magnetic-Filters\" rel=\"nofollow noopener\" target=\"_blank\">Eriez&#8217;s magnetic filter guide<\/a> distinguishes the background field used to rate its electromagnetic filters from the local field near the matrix.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"compare-evidence\">\n<h2>When Do You Need a Field Map, Pull Test, or Material Trial?<\/h2>\n<p><strong>Use a field map to compare the working zone, a repeatable pull test to check attraction to a specified test piece, and a material trial to verify what ends up in each outlet.<\/strong> Ask for the test that matches the decision you need to make.<\/p>\n<section class=\"level3\" id=\"when-is-a-map-enough-to-narrow-the-choice\">\n<h3>When is a map enough to narrow the choice?<\/h3>\n<p><strong>Use a map to narrow the choice when the question is where the field is concentrated and how it changes across the working zone.<\/strong> It can show whether a gap or edge needs attention. It is also useful when comparing a replacement magnet with a baseline taken on the same assembly. For a simulated map, check the model geometry, material and coil assumptions, and any measured points used to verify it. Ask for readings with the belt, liner, or cover in place when those parts change the working gap.<\/p>\n<\/section>\n<section class=\"level3\" id=\"how-do-you-compare-pull-tests-fairly\">\n<h3>How do you compare pull tests fairly?<\/h3>\n<p><strong>Match the test piece, its position, any spacer, and the direction of pull.<\/strong> Record the piece material, shape, size, and force units. Use the same setup for subsequent checks. In its 2004 tube-circuit comparison commissioned by Eriez, <a href=\"https:\/\/www.pennquip.com\/wp-content\/uploads\/2021\/01\/PSU_TEST_RESULTS.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Penn State Behrend<\/a> used an axial probe for gauss readings and a quarter-inch mild-steel sphere for surface pull tests. That is a defined test of the tube and sphere. To predict removal of irregular fines in your feed, compare the outlet samples from a running trial. See <a href=\"https:\/\/www.corvelanmag.com\/gauss-vs-pull-force\/\">gauss vs pull force<\/a> for more on matching pull-test conditions.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"capture-trouble\">\n<h2>Why Can Capture Fall While the Gauss Check Stays Steady?<\/h2>\n<p><strong>Start with when the misses occur.<\/strong> A stable reference reading points you toward changes in the feed path, target particles, or cleaning cycle. Look at the cleaned outlet, the captured fraction, and the operating log together.<\/p>\n<section class=\"level3\" id=\"do-misses-rise-when-feed-rate-or-particle-size-changes\">\n<h3>Do misses rise when feed rate or particle size changes?<\/h3>\n<p><strong>If misses rise during surges, compare bed depth or slurry flow with the good runs.<\/strong> Restore the previous feed conditions and sample again. If the pattern follows a new raw material or finer grind, compare the size and magnetic response of what escaped with the previous feed. For minerals, check whether the iron-bearing fraction is still liberated. That helps tell you whether to adjust the feed, change the separation zone, or use a different process step.<\/p>\n<\/section>\n<section class=\"level3\" id=\"does-capture-recover-after-cleaning\">\n<h3>Does capture recover after cleaning?<\/h3>\n<p><strong>If the outlet improves after cleaning, check buildup, stream diversion, and reject discharge near the end of the cycle.<\/strong> Record the time or mass processed before the change. Shorten the cleaning interval for a controlled run and compare the outlet at the same point in the cycle. If the reference reading itself has fallen, first repeat it at the same position, temperature and settings with a verified meter. A persistent change calls for inspection of the magnetic assembly and its operating conditions.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"trial-plan\">\n<h2>How Do You Run a Material Trial That Supports a Decision?<\/h2>\n<p><strong>Set a target for the cleaned product and a limit for saleable-material loss before the trial.<\/strong> Hold the feed conditions steady while you compare changes such as gap, roll speed, splitter position, or matrix configuration.<\/p>\n<section class=\"level3\" id=\"which-conditions-and-samples-should-match\">\n<h3>Which conditions and samples should match?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"Which conditions and samples should match?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-silica-sand-material-testing-20260907-073405.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>Split one representative lot between candidates and use the same sampling and assay method.<\/strong> Record the material, target contaminant, size distribution, moisture or slurry solids, operating rate, and equipment settings. Check the normal condition and the peak condition that could change the decision. Collect matched feed, cleaned product, and reject samples over a defined run interval. For a separator that accumulates material, include the catch removed during cleaning and record any material left in the unit. Use the same dry basis and analytical method when comparing solids assays. <a href=\"https:\/\/www.goudsmitmagnetics.com\/en-us\/services-knowledge-test-centre-for-magnets\" rel=\"nofollow noopener\" target=\"_blank\">Goudsmit&#8217;s test center<\/a> describes recycling trials with bulk samples from coarse to fine. For your trial, specify which equipment and feed conditions need to match production.<\/p>\n<\/section>\n<section class=\"level3\" id=\"how-do-you-separate-iron-removal-from-product-yield\">\n<h3>How do you separate iron removal from product yield?<\/h3>\n<p><strong>Use the mass of iron entering and leaving to calculate removal. Use the product mass to calculate mass yield.<\/strong> Suppose a trial starts with <strong>100 kg of dry mineral feed at 1.0% iron<\/strong> and produces <strong>90 kg of cleaned product at 0.30% iron<\/strong>, using the same total-iron assay for both. Assume the remaining 10 kg goes to the reject stream and that the machine holds no material at the end.<\/p>\n<ul>\n<li><strong>Iron in feed:<\/strong> 100 kg \u00d7 1.0% = 1.00 kg.<\/li>\n<li><strong>Iron left in cleaned product:<\/strong> 90 kg \u00d7 0.30% = 0.27 kg.<\/li>\n<li><strong>Iron removal by difference:<\/strong> (1.00 \u2212 0.27) \u00f7 1.00 \u00d7 100 = 73%.<\/li>\n<li><strong>Cleaned product mass yield:<\/strong> 90 \u00f7 100 \u00d7 100 = 90%.<\/li>\n<\/ul>\n<p>If the agreed residual limit is 0.35% Fe and the minimum mass yield is 92%, the result meets the iron limit and falls short on yield. Check the reject assay and close the mass balance. For a roll, look at whether a splitter move, a steadier thin feed, or a second stage can recover more good product while holding the iron limit. Retest the change under the agreed throughput. Where the goal is recovery of a valuable mineral, assay that mineral too. Total mass yield and valuable-mineral recovery answer different questions.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 field-card\" id=\"approval\">\n<h2>What Should You Put on the Quote and Acceptance Plan?<\/h2>\n<p><strong>Write down which field readings should be repeated and which separation results must pass at your operating rate.<\/strong> Agree on both while the supplier can still change the pole layout, opening, belt, or cleaning arrangement.<\/p>\n<section class=\"level3\" id=\"what-should-a-comparable-quote-include\">\n<h3>What should a comparable quote include?<\/h3>\n<p><strong>Request a drawing with the active face, feed path, and reading positions marked.<\/strong> State the normal and peak throughput, feed depth or flow, target particle or impurity, and expected outlet result. Ask for comparable measurements on that drawing, including probe orientation and installed layers. If the quote includes a pull value, attach the method and test-piece description. For mineral purification, state a residual assay and yield or recovery requirement. For tramp iron, agree on the relevant particle types or size classes and how the cleaned outlet will be sampled.<\/p>\n<\/section>\n<section class=\"level3\" id=\"what-should-you-check-when-the-machine-arrives\">\n<h3>What should you check when the machine arrives?<\/h3>\n<figure class=\"field-media\">\n<img loading=\"lazy\" alt=\"What should you check when the machine arrives?\" decoding=\"async\" height=\"900\" loading=\"lazy\" src=\"https:\/\/www.corvelanmag.com\/wp-content\/uploads\/2026\/11\/corvelan-qc-dimensional-verification-20260906-182934.webp\" width=\"1200\"\/>\n\n<\/figure>\n<p><strong>Check the built gap, belt or liner, and capture zone against the drawing.<\/strong> Repeat the agreed field or pull measurements and archive them as a baseline for service. Confirm the product and reject results at the agreed feed conditions, including the part of the cleaning cycle when capture is hardest. If the magnetic readings match and the process test misses its target, check the as-installed feeding, splitter or discharge arrangement and sampling method before changing the magnet.<\/p>\n<p>Before approving a separator, compare the field and its gradient where the target actually travels. Use a repeatable field or pull measurement to set the equipment baseline, then use the cleaned product and rejects from a representative run to make the performance decision.<\/p>\n<\/section>\n<\/section>\n<section class=\"level2 cta field-card\" data-article-section=\"cta\" id=\"contact\">\n<h2 class=\"cta\">Discuss Your Separator Setup With Corvelan<\/h2>\n<p>If you need to compare configurations, <strong>send us the material and target contaminant, size range, normal and peak throughput, and a sketch or dimensions of the installation point<\/strong>. Include the cleaned-product target and any existing field readings with their measurement positions. We can use those details to review the fit and identify what still needs a measurement or material test.<\/p>\n<p><a class=\"field-button\" href=\"https:\/\/www.corvelanmag.com\/contact-us\/\">Request a configuration review<\/a><\/p>\n<\/section>\n<section class=\"level2 faq field-card\" data-article-section=\"faq\" id=\"questions\">\n<h2 class=\"faq\">Questions About Gauss and Magnetic Field Gradient<\/h2>\n<section class=\"level3\" id=\"is-12000-gauss-a-useful-minimum-for-every-magnetic-separator\">\n<h3>Is 12,000 gauss a useful minimum for every magnetic separator?<\/h3>\n<p><strong>Use a gauss requirement tied to a defined machine, measurement position, and application.<\/strong> Set the numeric minimum from a comparable configuration and a test that meets your separation target. A tube surface value and a matrix filter&#8217;s background field are specified at different locations and serve different purposes.<\/p>\n<\/section>\n<section class=\"level3\" id=\"does-a-zero-reading-mean-theres-no-magnetic-field-there\">\n<h3>Does a zero reading mean there&#8217;s no magnetic field there?<\/h3>\n<p><strong>A single-axis probe can show near zero when its sensing axis is nearly perpendicular to the field.<\/strong> Check the probe zero and orientation, then take measurements along other axes or use a calibrated three-axis instrument if you need the field magnitude.<\/p>\n<\/section>\n<section class=\"level3\" id=\"can-i-estimate-the-gradient-along-a-diagonal-line\">\n<h3>Can I estimate the gradient along a diagonal line?<\/h3>\n<p><strong>Yes, the estimate describes the change along that diagonal.<\/strong> Keep the path angle and point spacing the same when comparing two setups. If separation depends on how quickly particles move across the stream toward a pole, add a measurement line in that direction.<\/p>\n<\/section>\n<section class=\"level3\" id=\"should-i-compare-readings-taken-cold-and-at-process-temperature\">\n<h3>Should I compare readings taken cold and at process temperature?<\/h3>\n<p><strong>Compare at the temperature that matches the application, with the same assembly and a probe rated for that temperature.<\/strong> Record the coil setting for an electromagnet. If readings drop while the unit heats up, check the magnet and instrument temperature limits and repeat under the same conditions before deciding what changed.<\/p>\n<\/section>\n<section class=\"level3\" id=\"why-do-my-readings-switch-from-positive-to-negative-across-pole-faces\">\n<h3>Why do my readings switch from positive to negative across pole faces?<\/h3>\n<p><strong>The component along the probe&#8217;s sensing axis can reverse direction.<\/strong> Mark the positions and retain the signed readings on a component map. If you need the gradient of the field magnitude for a particle-force comparison, use measured or modeled field components to determine the magnitude at each position.<\/p>\n<\/section>\n<section class=\"level3\" id=\"will-a-higher-gradient-remove-rust-or-every-kind-of-iron-oxide\">\n<h3>Will a higher gradient remove rust or every kind of iron oxide?<\/h3>\n<p><strong>Start by identifying the iron-bearing material and whether it is free to move.<\/strong> Magnetite and other iron oxides can respond very differently. An oxide coating attached to a saleable grain travels with that grain unless it is first freed. Test the actual feed and assay the cleaned and reject fractions to see what the separator removes.<\/p>\n<\/section>\n<section class=\"level3\" id=\"does-a-magnetic-separator-replace-a-downstream-metal-detector\">\n<h3>Does a magnetic separator replace a downstream metal detector?<\/h3>\n<p><strong>Use the separator to remove responsive material and choose a detector for the metal hazards the line still needs to monitor.<\/strong> Where a detector is part of the process, verify its response and reject function with the relevant test pieces and product conditions. Set the detector check separately from the separator&#8217;s field and capture tests.<\/p>\n<\/section>\n<section class=\"level3\" id=\"can-i-use-a-bare-magnet-field-map-after-adding-a-steel-wall\">\n<h3>Can I use a bare-magnet field map after adding a steel wall?<\/h3>\n<p><strong>Check the field with the wall installed.<\/strong> The wall adds spacing, and ferromagnetic steel can also redirect the flux. Use the actual wall material and thickness in the model or test, and compare readings on the product side.<\/p>\n<\/section>\n<section class=\"level3\" id=\"can-i-compare-field-map-colors-from-two-quotes\">\n<h3>Can I compare field-map colors from two quotes?<\/h3>\n<p><strong>First check that the two maps use the same numeric color scale, field quantity, and cross section.<\/strong> Ask for numerical values at the same distances and lateral positions. Two maps can use the same color for different fields.<\/p>\n<\/section>\n<section class=\"level3\" id=\"do-i-add-belt-thickness-if-the-field-map-starts-at-the-belt-surface\">\n<h3>Do I add belt thickness if the field map starts at the belt surface?<\/h3>\n<p><strong>Use the distance from the belt surface to the particle path when that surface is already the map&#8217;s zero.<\/strong> Record the belt thickness as part of the installed configuration. When comparing to readings referenced to the bare pole, bring both maps back to the same measured origin.<\/p>\n<\/section>\n<\/section>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is 12,000 gauss a useful minimum for every magnetic separator?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use a gauss requirement tied to a defined machine, measurement position, and application. Set the numeric minimum from a comparable configuration and a test that meets your separation target. A tube surface value and a matrix filter's background field are specified at different locations and serve different purposes.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a zero reading mean there's no magnetic field there?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A single-axis probe can show near zero when its sensing axis is nearly perpendicular to the field. Check the probe zero and orientation, then take measurements along other axes or use a calibrated three-axis instrument if you need the field magnitude.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I estimate the gradient along a diagonal line?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, the estimate describes the change along that diagonal. Keep the path angle and point spacing the same when comparing two setups. If separation depends on how quickly particles move across the stream toward a pole, add a measurement line in that direction.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Should I compare readings taken cold and at process temperature?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Compare at the temperature that matches the application, with the same assembly and a probe rated for that temperature. Record the coil setting for an electromagnet. If readings drop while the unit heats up, check the magnet and instrument temperature limits and repeat under the same conditions before deciding what changed.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why do my readings switch from positive to negative across pole faces?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The component along the probe's sensing axis can reverse direction. Mark the positions and retain the signed readings on a component map. If you need the gradient of the field magnitude for a particle-force comparison, use measured or modeled field components to determine the magnitude at each position.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Will a higher gradient remove rust or every kind of iron oxide?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Start by identifying the iron-bearing material and whether it is free to move. Magnetite and other iron oxides can respond very differently. An oxide coating attached to a saleable grain travels with that grain unless it is first freed. Test the actual feed and assay the cleaned and reject fractions to see what the separator removes.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does a magnetic separator replace a downstream metal detector?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use the separator to remove responsive material and choose a detector for the metal hazards the line still needs to monitor. Where a detector is part of the process, verify its response and reject function with the relevant test pieces and product conditions. Set the detector check separately from the separator's field and capture tests.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use a bare-magnet field map after adding a steel wall?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Check the field with the wall installed. The wall adds spacing, and ferromagnetic steel can also redirect the flux. Use the actual wall material and thickness in the model or test, and compare readings on the product side.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I compare field-map colors from two quotes?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"First check that the two maps use the same numeric color scale, field quantity, and cross section. Ask for numerical values at the same distances and lateral positions. Two maps can use the same color for different fields.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do I add belt thickness if the field map starts at the belt surface?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Use the distance from the belt surface to the particle path when that surface is already the map's zero. Record the belt thickness as part of the installed configuration. When comparing to readings referenced to the bare pole, bring both maps back to the same measured origin.\"\n      }\n    }\n  ]\n}\n<\/script>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Gauss tells you the magnetic flux density at one point. The magnetic field gradient tells you how quickly the field changes across a distance. To compare magnetic separators, ask for field readings and their change where the particles actually travel. Then run representative material at the feed rate you need and check both the cleaned [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3933,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5202","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/posts\/5202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/comments?post=5202"}],"version-history":[{"count":4,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/posts\/5202\/revisions"}],"predecessor-version":[{"id":6237,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/posts\/5202\/revisions\/6237"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/media\/3933"}],"wp:attachment":[{"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/media?parent=5202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/categories?post=5202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.corvelanmag.com\/ru\/wp-json\/wp\/v2\/tags?post=5202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}